Comparative Analysis Between the Effect of Type III and Type IV Generators on Risk of Harmonic Resonances in Wind Parks

This paper provides a detailed comparative analysis between the effect of Type III and Type IV generator technologies on the risk of harmonic resonances in wind parks. Initially, the model and characteristics of Type III and Type IV generators at harmonic frequencies are reviewed. Then, an index based on harmonic amplification at the point of common coupling (PCC) is defined to quantify the overall risk of harmonic resonance in the park. This index is employed to determine and compare the effect of Type III and Type IV generators in different scenarios. Factors such as parameters of the generators, of the wind park circuit, and of the background grid are analyzed. The results reveal that, under the same design premises, Type III-based wind parks tend to present higher risk of resonance than Type IV-based parks at low order harmonics such as the 5th and 7th harmonics.

[1]  W. Freitas,et al.  A Graphical Method to Assess Component Overload Due to Harmonic Resonances in Wind Parks , 2021, IEEE Transactions on Power Delivery.

[2]  Honggeng Yang,et al.  Improved modal sensitivity analysis-based method for harmonic resonance analysis , 2021, Electric Power Systems Research.

[3]  Andrés Argüello Simplified Analytic Procedure to Calculate the Electric Variables at Steady State of Type-III and Type-IV Wind Generators , 2020, 2020 IEEE PES Transmission & Distribution Conference and Exhibition - Latin America (T&D LA).

[4]  T. Rasmussen,et al.  Mitigation of Harmonic Voltage Amplification in Offshore Wind Power Plants by Wind Turbines With Embedded Active Filters , 2020, IEEE Transactions on Sustainable Energy.

[5]  Walmir Freitas,et al.  Practical Chart for Harmonic Resonance Assessment of DFIG-Based Wind Parks , 2020, IEEE Transactions on Power Delivery.

[6]  Mustafa Dursun,et al.  LCL Filter Design for Grid Connected Three-Phase Inverter , 2018, 2018 2nd International Symposium on Multidisciplinary Studies and Innovative Technologies (ISMSIT).

[7]  Di Wu,et al.  Assessing Impact of Renewable Energy Integration on System Strength Using Site-Dependent Short Circuit Ratio , 2018, IEEE Transactions on Sustainable Energy.

[8]  Frede Blaabjerg,et al.  Overview of DFIG-Based Wind Power System Resonances Under Weak Networks , 2017, IEEE Transactions on Power Electronics.

[9]  Ke Ma,et al.  Wind Energy Systems , 2017, Proceedings of the IEEE.

[10]  Zifa Liu,et al.  Harmonic Assessment for Wind Parks Based on Sensitivity Analysis , 2017, IEEE Transactions on Sustainable Energy.

[11]  Math Bollen,et al.  Decompositions of harmonic propagation in wind power plant , 2016 .

[12]  Jun Liang,et al.  Study of resonance in wind parks , 2015 .

[13]  C. Larose,et al.  Type-III Wind Power Plant Harmonic Emissions: Field Measurements and Aggregation Guidelines for Adequate Representation of Harmonics , 2013, IEEE Transactions on Sustainable Energy.

[14]  B. Badrzadeh,et al.  Harmonics and resonance issues in wind power plants , 2012, 2011 IEEE Power and Energy Society General Meeting.

[15]  Mona N. Eskander,et al.  Sizing of Converters Interfacing the Rotor of Wind Driven DFIG to the Power Grid , 2011 .

[16]  N. Samaan,et al.  Reactive power compensation for wind power plants , 2009, 2009 IEEE Power & Energy Society General Meeting.

[17]  Yonggang Zhang,et al.  Study of resonance issues between DFIG-based offshore wind farm and HVDC transmission , 2021 .

[18]  Esmaeil Ebrahimzadeh,et al.  Harmonic Stability and Resonance Analysis in Large PMSG-Based Wind Power Plants , 2018, IEEE Transactions on Sustainable Energy.