Limitations of animal electrical cardiac safety models

Introduction - Human electrical safety standards are based almost exclusively on animal studies and there is an unjustified assumption that ventricular fibrillation (VF) thresholds in animals are the same as those in humans. Methods and Results - We analyzed differences between animals and humans in cardiac stimulation. A broad literature survey revealed that swine are a fragile electrophysiologic research species and have a dense intramural Purkinje fiber network, which is not found in some other species, including humans. Anesthesia agents have to be chosen carefully as swine are prone to malignant hyperthermia. Cardiac stimulation thresholds depend on weight and capture rates. Thus, the animal weight has to be representative of the weight of human subjects. Studies have shown significant ECG differences between humans and other species, including swine and canine. At least one study suggested that rabbit hearts tend to develop VF in a manner more similar to that seen in humans. Conclusion - Animal studies can play a role in conservatively evaluating cardiac safety. However, while still abiding by the precautionary principle, animal study design has to take into account the significant anatomical and electrophysiological differences between humans and other mammals. Data from multiple animal models may offer broader perspectives. If attempts are made to extrapolate animal results to humans then appropriate numerical correction factors should be applied, such as some of those discussed in this article.

[1]  Dhanunjaya R. Lakkireddy,et al.  Effects of cocaine intoxication on the threshold for stun gun induction of ventricular fibrillation. , 2006, Journal of the American College of Cardiology.

[2]  Dorin Panescu,et al.  Electrical safety of conducted electrical weapons relative to requirements of relevant electrical standards , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Long-Sheng Song,et al.  Propofol and arrhythmias: two sides of the coin , 2011, Acta Pharmacologica Sinica.

[4]  R. Ideker,et al.  The Importance of Purkinje Activation in Long Duration Ventricular Fibrillation , 2014, Journal of the American Heart Association.

[5]  Jeffrey D Ho,et al.  An evaluation of two conducted electrical weapons and two probe designs using a swine comparative cardiac safety model , 2013, Forensic Science, Medicine, and Pathology.

[6]  S. Stratton Sudden In-Custody Death , 2009 .

[7]  J. W. van der Laan,et al.  Regulatory acceptability of the minipig in the development of pharmaceuticals, chemicals and other products. , 2010, Journal of pharmacological and toxicological methods.

[8]  E. Downar,et al.  Cardiac electrophysiological consequences of neuromuscular incapacitating device discharges. , 2006, Journal of the American College of Cardiology.

[9]  Alexander V Panfilov,et al.  Is heart size a factor in ventricular fibrillation? Or how close are rabbit and human hearts? , 2006, Heart rhythm.

[10]  C. F. Dalziel,et al.  Reevaluation of Lethal Electric Currents , 1968 .

[11]  K. Nagy,et al.  TASER X26 discharges in swine produce potentially fatal ventricular arrhythmias. , 2008, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[12]  J. Webster,et al.  Optimisation of transcutaneous cardiac pacing by three-dimensional finite element modelling of the human thorax , 1995, Medical and Biological Engineering and Computing.

[13]  R. Ideker,et al.  Transmural and endocardial Purkinje activation in pigs before local myocardial activation after defibrillation shocks. , 2007, Heart rhythm.

[14]  K. Nagy,et al.  Taser X26 discharges in swine: ventricular rhythm capture is dependent on discharge vector. , 2008, The Journal of trauma.

[15]  Jian Huang,et al.  Evolution of activation patterns during long-duration ventricular fibrillation in pigs. , 2004, American journal of physiology. Heart and circulatory physiology.

[16]  R A Malkin,et al.  Cardiovascular collapse caused by electrocardiographically silent 60-Hz intracardiac leakage current. Implications for electrical safety. , 1999, Circulation.

[17]  R. Gourdie,et al.  Why do we have Purkinje fibers deep in our heart? , 2014, Physiological research.

[18]  Hui-Nam Pak,et al.  Role of the Posterior Papillary Muscle and Purkinje Potentials in the Mechanism of Ventricular Fibrillation in Open Chest Dogs and Swine: Effects of Catheter Ablation , 2006, Journal of cardiovascular electrophysiology.

[19]  Armando Pérez de Prado,et al.  Ventricular arrhythmias and mortality associated with isoflurane and sevoflurane in a porcine model of myocardial infarction. , 2011, Journal of the American Association for Laboratory Animal Science : JAALAS.

[20]  J. Heffron,et al.  Porcine stress syndromes. , 1982, Advances in food research.

[21]  B. G. King,et al.  Effect of electric shock on the heart , 1936, Electrical Engineering.

[22]  G. Krishna,et al.  Effect of age on epinephrine-induced arrhythmias during halothane anaesthesia in pigs , 1984, Canadian Anaesthetists' Society journal.

[23]  R. Hamlin,et al.  Ventricular activation process in minipigs. , 1975, Journal of Electrocardiology.

[24]  L A Geddes,et al.  Threshold 60-Hz current required for ventricular fibrillation in subjects of various body weights. , 1973, IEEE transactions on bio-medical engineering.

[25]  David O. Martin,et al.  Cardiac Effects of Electrical Stun Guns: Does Position of Barbs Contact Make a Difference? , 2008, Pacing and clinical electrophysiology : PACE.

[26]  J. Pippin Taser research in pigs not helpful. , 2007, Journal of the American College of Cardiology.

[27]  K. Nagy,et al.  Acute effects of TASER X26 discharges in a swine model. , 2007, The Journal of trauma.

[28]  Donald M Dawes,et al.  An evaluation of two conducted electrical weapons using a swine comparative cardiac safety model , 2014, Forensic Science, Medicine, and Pathology.

[29]  Dorin Panescu,et al.  Essentials of low-power electrocution: Established and speculated mechanisms , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.