New reference intervals for thyrotropin and thyroid hormones based on National Academy of Clinical Biochemistry criteria and regular ultrasonography of the thyroid.

BACKGROUND The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of these intervals. METHODS We investigated 870 apparently healthy persons and excluded, step by step, those with a family history of thyroid disease, pathologic thyroid ultrasonography results, and increased anti-thyroid peroxidase or anti-thyroglobulin antibodies. Accordingly, only 453 of the 870 persons in the entire group were finally included as reference collective. We measured serum concentrations of TSH, total and free thyroxine (T(4) and FT(4)), and total and free triiodothyronine (T(3) and FT(3)) of the whole and the reference collective on the ELECSYS system assays (Roche Diagnostics) and calculated the 2.5th and 97.5th percentiles for comparison. RESULTS The calculated lower limit for TSH differed significantly between the reference intervals for healthy persons with an assessed normal thyroid gland vs the nonselected group of healthy blood donors. Age was the only independent factor and was significantly inversely associated with TSH (P <0.0001). Use of oral contraceptives was a significant predictor for variation in T(4) concentrations (P <0.001). Age and oral contraceptives were independently associated with T(3) variations (P <0.05). For FT(4) vs FT(3) variation, gender and (inversely) age (P <0.01) were independent modulating factors. CONCLUSIONS The selection of healthy persons according to NACB criteria combined with sonographic confirmation of a normal thyroid gland provide a valid basis for the reference interval for TSH. Factors indicating a preclinical disease state, such as family history, pathologic ultrasonography result, or increased anti-thyroid peroxidase and anti-thyroglobulin antibodies, can be associated with normal hormone concentrations. Additionally, patient age and gender as well as use of contraceptives should be considered in diagnostic evaluation of thyroid diseases.

[1]  J. Chu,et al.  The treatment of subclinical hypothyroidism is seldom necessary. , 2001, The Journal of clinical endocrinology and metabolism.

[2]  E. Bruck,et al.  National Committee for Clinical Laboratory Standards. , 1980, Pediatrics.

[3]  G. Assmann,et al.  Elecsys TSH, FT4, T4, T-uptake, FT3 and T3. Clinical results of a multicentre study. , 1998, Wiener klinische Wochenschrift.

[4]  T. Demant,et al.  Evaluation of the LIAISON thyroid chemiluminescence immunoassays. , 2000, Clinical laboratory.

[5]  H E Solberg,et al.  International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values, and International Committee for Standardization in Haematology (ICSH), Standing Committee on Reference Values. Approved Recommendation (1986) on the theory of re , 1987, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.

[6]  H E Solberg,et al.  The theory of reference values Part 5. Statistical treatment of collected reference values. Determination of reference limits. , 1983, Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie.

[7]  Laboratory medicine practice guidelines. Laboratory support for the diagnosis and monitoring of thyroid disease. , 2001, Thyroid : official journal of the American Thyroid Association.

[8]  B. Goichot,et al.  Evaluation of Elecsys free triiodothyronine assay: relevance of age-related reference ranges. , 1998, Clinical biochemistry.

[9]  N. Weintraub,et al.  Current controversies in endocrinology: screening of asymptomatic elderly for subclinical hypothyroidism. , 2004, Journal of the American Medical Directors Association.

[10]  H. E. Solberg,et al.  Approved recommendation (1986) on the theory of reference values. Part 1. The concept of reference values. , 1987 .

[11]  Carmen,et al.  Regional Reference Values for some Quantities Measured with the ADVIA Centaur Analyser. A Model of Co-operation between the In Vitro Diagnostic Industry and Clinical Laboratories , 2001, Clinical chemistry and laboratory medicine.

[12]  P. Pfannenstiel,et al.  [Ultrasonic diagnosis of the thyroid gland]. , 2008, Deutsche medizinische Wochenschrift.

[13]  F. Martín-Gil,et al.  Population-specific reference values for thyroid hormones on the Abbott ARCHITECT i2000 analyzer , 2004, Clinical chemistry and laboratory medicine.

[14]  P. Laurberg,et al.  Biologic variation is important for interpretation of thyroid function tests. , 2003, Thyroid : official journal of the American Thyroid Association.

[15]  G. Kovacs,et al.  Comparative analytical evaluation of thyroid hormone levels in pregnancy and in women taking oral contraceptives: a study from an iodine deficient area , 2004, Gynecological endocrinology : the official journal of the International Society of Gynecological Endocrinology.

[16]  W Harry Hannon,et al.  Serum TSH, T(4), and thyroid antibodies in the United States population (1988 to 1994): National Health and Nutrition Examination Survey (NHANES III). , 2002, The Journal of clinical endocrinology and metabolism.

[17]  I. Hanning,et al.  A Model for a Multicentre Approach to the Derivation of Reference Intervals for Thyroid Hormones and Testosterone for Laboratories Using Identical Analysers , 2000, Clinical chemistry and laboratory medicine.

[18]  U. John,et al.  Reference intervals of serum thyroid function tests in a previously Iodine-deficient area , 2005 .

[19]  J. Schlienger,et al.  Elecsys thyrotropin (TSH) assay evaluated. , 1997, Clinical chemistry.

[20]  O. M. Pedersen,et al.  The value of ultrasonography in predicting autoimmune thyroid disease. , 2000, Thyroid : official journal of the American Thyroid Association.

[21]  C. Fraser,et al.  Intra- and interindividual biological variation of five analytes used in assessing thyroid function: implications for necessary standards of performance and the interpretation of results. , 1986, Clinical chemistry.

[22]  T. Demant,et al.  Reference Intervals for Thyroid Hormones on the Architect Analyser , 2002, Clinical chemistry and laboratory medicine.

[23]  J. Franklyn,et al.  Subclinical thyroid disease: scientific review and guidelines for diagnosis and management. , 2004, JAMA.

[24]  P. Scriba,et al.  [Volumetric analysis of thyroid lobes by real-time ultrasound (author's transl)]. , 2008, Deutsche medizinische Wochenschrift.

[25]  I. Wiegratz,et al.  Effect of four oral contraceptives on thyroid hormones, adrenal and blood pressure parameters. , 2003, Contraception.