Radiation effects on astrometric CCDs at low operating temperatures

Emission times of proton-induced traps and optical spot profiles have been measured at temperatures around -110/spl deg/C for large format charge-coupled devices (CCDs), representative of those to be used for the Gaia mission. There are at least seven trap species involved, with emission times in the range 0.3 /spl mu/s to 130 s and there is evidence for charge re-trapping by fast traps. Trap filling using a charge injection gate is discussed.

[1]  J. R. Troxell Ion-implantation associated defect production in silicon , 1983 .

[2]  Beverly LaMarr,et al.  Radiation damage in the Chandra x-ray CCDs , 2000, Astronomical Telescopes and Instrumentation.

[3]  B. LaMarr,et al.  Anomalous annealing of a high-resistivity CCD irradiated at low temperature , 2005, IEEE Transactions on Nuclear Science.

[4]  Bryan N. Dorland Modeling the effects of proton damage to CCDs on astrometric measurement precision , 2004, SPIE Optics + Photonics.

[5]  Dennis J. Gallagher,et al.  Monte Carlo model for describing charge transfer in irradiated CCDs , 1998, Electronic Imaging.

[6]  G. R. Hopkinson,et al.  Proton-induced CCD charge transfer degradation at low-operating temperatures , 2001 .

[7]  A. Mohammadzadeh,et al.  Comparison of CCD damage due to 10- and 60-MeV protons , 2003 .

[8]  M. F. Tompsett,et al.  II-3 the effects of bulk traps on the performance of bulk channel charge-coupled devices , 1974 .

[9]  Ian B. Hutchinson,et al.  Low-noise charge injection in the CCD22 , 2004, SPIE Astronomical Telescopes + Instrumentation.

[10]  A. Mohammadzadeh,et al.  RADIATION EFFECTS IN CHARGE-COUPLED DEVICE (CCD) IMAGERS AND CMOS ACTIVE PIXEL SENSORS , 2004 .

[11]  Gregory Y. Prigozhin,et al.  X-ray CCD with charge-injection structure , 2004, SPIE Astronomical Telescopes + Instrumentation.

[12]  Augustyn Waczynski,et al.  Effects of radiation damage on astrometric CCDs: comparison of STA700 and e2v Model 43 detectors , 2004, SPIE Astronomical Telescopes + Instrumentation.

[13]  M. Giavalisco Minimizing CTE losses in the WFC3 CCDs: Post Flash vs. Charge Injection , 2003 .

[14]  Ian Hutchinson,et al.  Gaia astrometric CCDs and focal plane , 2005, SPIE Optics + Photonics.

[15]  P. W. Marshall,et al.  Displacement damage effects in mixed particle environments for shielded spacecraft CCDs , 1993 .

[16]  Edward S. Cheng,et al.  A comparison of charge transfer efficiency measurement techniques on proton damaged n-channel CCDs for the Hubble Space Telescope Wide-Field Camera 3 , 2001 .

[17]  R. H. Philbrick,et al.  Modeling the impact of preflushing on CTE in proton irradiated CCD-based detectors , 2002 .