Minimizing discordances in automated classification of fractionated electrograms in human persistent atrial fibrillation

Ablation of persistent atrial fibrillation (persAF) targeting complex fractionated atrial electrograms (CFAEs) detected by automated algorithms has produced conflicting outcomes in previous electrophysiological studies. We hypothesize that the differences in these algorithms could lead to discordant CFAE classifications by the available mapping systems, giving rise to potential disparities in CFAE-guided ablation. This study reports the results of a head-to-head comparison of CFAE detection performed by NavX (St. Jude Medical) versus CARTO (Biosense Webster) on the same bipolar electrogram data (797 electrograms) from 18 persAF patients. We propose revised thresholds for both primary and complementary indices to minimize the differences in CFAE classification performed by either system. Using the default thresholds [NavX: CFE-Mean ≤ 120 ms; CARTO: ICL ≥ 7], NavX classified 70 % of the electrograms as CFAEs, while CARTO detected 36 % (Cohen’s kappa κ ≈ 0.3, P < 0.0001). Using revised thresholds found using receiver operating characteristic curves [NavX: CFE-Mean ≤ 84 ms, CFE-SD ≤ 47 ms; CARTO: ICL ≥ 4, ACI ≤ 82 ms, SCI ≤ 58 ms], NavX classified 45 %, while CARTO detected 42 % (κ ≈ 0.5, P < 0.0001). Our results show that CFAE target identification is dependent on the system and thresholds used by the electrophysiological study. The thresholds found in this work counterbalance the differences in automated CFAE classification performed by each system. This could facilitate comparisons of CFAE ablation outcomes guided by either NavX or CARTO in future works.

[1]  Jacob Cohen,et al.  Weighted kappa: Nominal scale agreement provision for scaled disagreement or partial credit. , 1968 .

[2]  Atul Verma,et al.  Ablation for longstanding permanent atrial fibrillation: results from a randomized study comparing three different strategies. , 2008, Heart rhythm.

[3]  K. Nademanee,et al.  A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. , 2004, Journal of the American College of Cardiology.

[4]  B. Knight,et al.  Approaches to catheter ablation of persistent atrial fibrillation. , 2009, Heart rhythm.

[5]  Prashanthan Sanders,et al.  High-density activation mapping of fractionated electrograms in the atria of patients with paroxysmal atrial fibrillation. , 2006, Heart rhythm.

[6]  Anthony Aizer,et al.  Standardization and validation of an automated algorithm to identify fractionation as a guide for atrial fibrillation ablation. , 2008, Heart rhythm.

[7]  Omer Berenfeld,et al.  Rotor meandering contributes to irregularity in electrograms during atrial fibrillation. , 2008, Heart rhythm.

[8]  Kawal S. Rhode,et al.  Towards personalized clinical in-silico modeling of atrial anatomy and electrophysiology , 2012, Medical & Biological Engineering & Computing.

[9]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[10]  G. Monir,et al.  Consistency of the CFAE Phenomena Using Custom Software for Automated Detection of Complex Fractionated Atrial Electrograms (CFAEs) in the Left Atrium During Atrial Fibrillation , 2008, Journal of cardiovascular electrophysiology.

[11]  Omer Berenfeld,et al.  Mechanisms of fractionated electrograms formation in the posterior left atrium during paroxysmal atrial fibrillation in humans. , 2011, Journal of the American College of Cardiology.

[12]  Ryo Haraguchi,et al.  The Role of Fibroblasts in Complex Fractionated Electrograms During Persistent/Permanent Atrial Fibrillation: Implications for Electrogram-Based Catheter Ablation , 2012, Circulation research.

[13]  Nicolas Derval,et al.  Classifying fractionated electrograms in human atrial fibrillation using monophasic action potentials and activation mapping: evidence for localized drivers, rate acceleration, and nonlocal signal etiologies. , 2011, Heart rhythm.

[14]  Hugh Calkins,et al.  Long‐ and Short‐Term Temporal Stability of Complex Fractionated Atrial Electrograms in Human Left Atrium During Atrial Fibrillation , 2009, Journal of cardiovascular electrophysiology.

[15]  Sanjay Dixit,et al.  Effect of pulmonary vein isolation on the distribution of complex fractionated electrograms in humans. , 2009, Heart rhythm.

[16]  S. Knecht,et al.  Is Mapping of Complex Fractionated Electrograms Obsolete? , 2015, Arrhythmia & electrophysiology review.

[17]  J. R. Landis,et al.  The measurement of observer agreement for categorical data. , 1977, Biometrics.

[18]  Prashanthan Sanders,et al.  Indices of bipolar complex fractionated atrial electrograms correlate poorly with each other and atrial fibrillation substrate complexity. , 2015, Heart rhythm.

[19]  Jason Ng,et al.  Measuring the Complexity of Atrial Fibrillation Electrograms , 2010, Journal of cardiovascular electrophysiology.

[20]  Glyn Thomas,et al.  Validation of a classification system to grade fractionation in atrial fibrillation and correlation with automated detection systems. , 2009, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[21]  Tom Fawcett,et al.  An introduction to ROC analysis , 2006, Pattern Recognit. Lett..

[22]  Yu-Feng Hu,et al.  Efficacy of Additional Ablation of Complex Fractionated Atrial Electrograms for Catheter Ablation of Nonparoxysmal Atrial Fibrillation , 2009, Journal of cardiovascular electrophysiology.

[23]  Wolters Kluwer,et al.  Hrs/ehra/ecas Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Patient Selection, Procedural Techniques, Patient Management and Follow-up, Definitions, Endpoints, and Research Trial Design: a Report of the Heart Rhythm Society (hrs) Task Force , 2022 .

[24]  D. Wilber,et al.  Prospective Study of Atrial Fibrillation Termination During Ablation Guided by Automated Detection of Fractionated Electrograms , 2008, Journal of cardiovascular electrophysiology.

[25]  Hoshiar Abdollah,et al.  Temporo-spatial stability of complex fractionated atrial electrograms in two distinct and separate episodes of paroxysmal atrial fibrillation. , 2009, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[26]  David Keane,et al.  2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[27]  L. Lo,et al.  Consistency of the Automatic Algorithm in Detecting Complex Fractionated Electrograms using an Electroanatomical Navigation System , 2012, Pacing and clinical electrophysiology : PACE.

[28]  Suman Kundu,et al.  Regional fractionation and dominant frequency in persistent atrial fibrillation: effects of left atrial ablation and evidence of spatial relationship. , 2011, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[29]  Dhanunjaya R. Lakkireddy,et al.  Relationship Between Complex Fractionated Electrograms (CFE) and Dominant Frequency (DF) Sites and Prospective Assessment of Adding DF‐Guided Ablation to Pulmonary Vein Isolation in Persistent Atrial Fibrillation (AF) , 2011, Journal of cardiovascular electrophysiology.

[30]  Atul Verma,et al.  Substrate and Trigger Ablation for Reduction of Atrial Fibrillation (STAR AF): a randomized, multicentre, international trial† , 2010, European heart journal.

[31]  Jacques M T de Bakker,et al.  The Pathophysiologic Basis of Fractionated and Complex Electrograms and the Impact of Recording Techniques on Their Detection and Interpretation , 2010, Circulation. Arrhythmia and electrophysiology.

[32]  Frank Bogun,et al.  Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms , 2007, Circulation.

[33]  Frank Bogun,et al.  A randomized assessment of the incremental role of ablation of complex fractionated atrial electrograms after antral pulmonary vein isolation for long-lasting persistent atrial fibrillation. , 2009, Journal of the American College of Cardiology.