A Reliable Protection Scheme for Fast DC Fault Clearance in a VSC-Based Meshed MTDC Grid

A multi-terminal high voltage DC (MTDC) grid, is an optimum and cost-effective transmission network to minimize the energy crisis worldwide largely. However, the core demand for a fast DC protection scheme with an extraordinary strict fault clearance time of a few milliseconds, is a key research gap in this network, holding back its development and scalability. To bridge this gap, this paper proposes a novel protection scheme for a meshed MTDC grid. The main goals of the scheme include accurate discrimination of a faulty line, rapid fault detection, fault location estimation, significant fault current reduction, and fully selective isolation of only the faulted line, while continuing normal power flow in the healthy grid zones. Reliability of the scheme for long and extra-long-distance power transmission is increased by aiding the differential protection and Type-D traveling wave (TW)-based algorithms utilizing the distributed optical current sensing technology with the other auxiliary methods and backup plans. These auxiliary methods include independent discrete wavelet transform (DWT), current derivative polarity principles with a minimum sample (short time) window, overcurrent relays, and AC circuit breakers (ACCBs). A faulty segment of a transmission line is accurately discriminated from the healthy ones by measuring a series of multi-point differential currents on it. A faulty line at a particular DC node is accurately discriminated using the differential protection by measuring the current flowing into or out of each line from each side at every node to obtain the algebraic sum. The current sum of a real-time local transient data and a delayed remote data is compared to a preset threshold level. DC fault current is significantly reduced below the breakable levels by coordinating bidirectional hybrid DC circuit breakers (HDCCBs) with the active and passive fault current limiters (FCLs) and the half bridge-VSC-based modular multilevel converters (MMCs). The proposed concepts are successfully verified by the simulation results under a variety of fault scenarios and are found to be accurate.

[1]  Goran Strbac,et al.  A new fault-ride-through strategy for MTDC networks incorporating wind farms and modular multi-level converters , 2017 .

[2]  Zhe Chen,et al.  Design of Protective Inductors for HVDC Transmission Line Within DC Grid Offshore Wind Farms , 2013, IEEE Transactions on Power Delivery.

[3]  Cora Petino,et al.  Application of multilevel full bridge converters in HVDC multiterminal systems , 2016 .

[4]  Grzegorz Fusiek,et al.  Single-Ended Differential Protection in MTDC Networks Using Optical Sensors , 2017, IEEE Transactions on Power Delivery.

[5]  O. Falou,et al.  Mean Scatterer Spacing Estimation Using Cepstrum-Based Continuous Wavelet Transform , 2020, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[6]  Maryam Saeedifard,et al.  Optimum Selection of Circuit Breaker Parameters Based on Analytical Calculation of Overcurrent and Overvoltage in Multiterminal HVDC Grids , 2020, IEEE Transactions on Industrial Electronics.

[7]  Umer Amir Khan,et al.  A Novel Model of HVDC Hybrid-Type Superconducting Circuit Breaker and Its Performance Analysis for Limiting and Breaking DC Fault Currents , 2015, IEEE Transactions on Applied Superconductivity.

[8]  Guidong Zhang,et al.  Power electronics converters: Past, present and future , 2018 .

[9]  Xinzhou Dong,et al.  Novel Fault Location in MTDC Grids With Non-Homogeneous Transmission Lines Utilizing Distributed Current Sensing Technology , 2018, IEEE Transactions on Smart Grid.

[10]  Li Ren,et al.  Study on Coordination of Resistive SFCLs and Hybrid-Type Circuit Breakers to Protect a HVDC System With LCC and VSC Stations , 2020, IEEE Transactions on Applied Superconductivity.

[11]  Boon-Teck Ooi,et al.  Locating and Isolating DC Faults in Multi-Terminal DC Systems , 2007, IEEE Transactions on Power Delivery.

[12]  Wenyuan Wang,et al.  Impact of DC Breaker Systems on Multiterminal VSC-HVDC Stability , 2016, IEEE Transactions on Power Delivery.

[13]  Rui Dantas,et al.  Progressive Fault Isolation and Grid Restoration Strategy for MTDC Networks , 2018, IEEE Transactions on Power Delivery.

[14]  Liangzhong Yao,et al.  DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change Rate , 2017, IEEE Transactions on Power Delivery.

[15]  Erik Martinsen,et al.  Evaluation of Methods for Detecting and Locating Faults in HVDC Grids , 2014 .

[16]  R. P. P. Smeets,et al.  Test Circuits for HVDC Circuit Breakers , 2017, IEEE Transactions on Power Delivery.

[17]  Liye Xiao,et al.  A DC Fault Protection Scheme for MMC-HVDC Grids Using New Directional Criterion , 2021, IEEE Transactions on Power Delivery.

[18]  P. Bauer,et al.  Impact of HVDC Transmission System Topology on Multiterminal DC Network Faults , 2015, IEEE Transactions on Power Delivery.

[19]  Nengling Tai,et al.  Transient-Voltage-Based Protection Scheme for DC Line Faults in the Multiterminal VSC-HVDC System , 2017, IEEE Transactions on Power Delivery.

[20]  Xu Dianguo,et al.  Coordinated Operation and Control of VSC Based Multiterminal High Voltage DC Transmission Systems , 2016, IEEE Transactions on Sustainable Energy.

[21]  Cansin Yaman Evrenosoglu,et al.  A single-ended fault location method for segmented HVDC transmission line , 2014 .

[22]  Qian Xu,et al.  Optimized Power Redistribution of Offshore Wind Farms Integrated VSC-MTDC Transmissions After Onshore Converter Outage , 2017, IEEE Transactions on Industrial Electronics.

[23]  Chong Liu,et al.  Line-to-Line Fault Analysis and Location in a VSC-Based Low-Voltage DC Distribution Network , 2018 .

[24]  R. Wachal,et al.  Location of DC Line Faults in Conventional HVDC Systems With Segments of Cables and Overhead Lines Using Terminal Measurements , 2012, IEEE Transactions on Power Delivery.