Water-fat separation incorporating spatial smoothing is robust to noise.

PURPOSE To develop and evaluate a noise-robust method for reconstruction of water and fat images for spoiled gradient multi-echo sequences. METHODS The proposed method performs water-fat separation by using a graph cut to minimize an energy function consisting of unary and binary terms. Spatial smoothing is incorporated to increase robustness to noise. The graph cut can fail to find a solution covering the entire image, in which case the relative weighting of the unary term is iteratively increased until a complete solution is found. The proposed method was compared to two previously published methods. Reconstructions were performed on 16 cases taken from the 2012 ISMRM water-fat reconstruction challenge dataset, for which reference reconstructions were provided. Robustness towards noise was evaluated by reconstructing images with different levels of noise added. The percentage of water-fat swaps were calculated to measure performance. RESULTS At low noise levels the proposed method produced similar results to one of the previously published methods, while outperforming the other. The proposed method significantly outperformed both of the previously published methods at moderate and high noise levels. CONCLUSION By incorporating spatial smoothing, an increased robustness towards noise is achieved when performing water-fat reconstruction of spoiled gradient multi-echo sequences.

[1]  P Kellman,et al.  Joint estimation of water/fat images and field inhomogeneity map , 2008, Magnetic resonance in medicine.

[2]  W. T. Dixon Simple proton spectroscopic imaging. , 1984, Radiology.

[3]  Jingfei Ma,et al.  A single‐point dixon technique for fat‐suppressed fast 3D gradient‐echo imaging with a flexible echo time , 2008, Journal of magnetic resonance imaging : JMRI.

[4]  Peter Börnert,et al.  Chemical shift encoding‐based water–fat separation methods , 2014, Journal of magnetic resonance imaging : JMRI.

[5]  Joel G Fletcher,et al.  Dual echo Dixon imaging with a constrained phase signal model and graph cuts reconstruction , 2017, Magnetic resonance in medicine.

[6]  Wenmiao Lu,et al.  Multiresolution field map estimation using golden section search for water‐fat separation , 2008, Magnetic resonance in medicine.

[7]  Norbert J Pelc,et al.  Field map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition , 2005, Magnetic resonance in medicine.

[8]  Joel Kullberg,et al.  Three‐dimensional water/fat separation and T  2* estimation based on whole‐image optimization—Application in breathhold liver imaging at 1.5 T , 2012, Magnetic resonance in medicine.

[9]  J. Besag On the Statistical Analysis of Dirty Pictures , 1986 .

[10]  Vladimir Kolmogorov,et al.  Minimizing Nonsubmodular Functions with Graph Cuts-A Review , 2007, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[11]  Xiaodong Wu,et al.  Fat water decomposition using globally optimal surface estimation (GOOSE) algorithm , 2015, Magnetic resonance in medicine.

[12]  Scott B Reeder,et al.  Robust multipoint water‐fat separation using fat likelihood analysis , 2012, Magnetic resonance in medicine.

[13]  Q. Xiang,et al.  Water‐fat imaging with direct phase encoding , 1997, Journal of magnetic resonance imaging : JMRI.

[14]  Johan Berglund,et al.  Multi‐scale graph‐cut algorithm for efficient water‐fat separation , 2017, Magnetic resonance in medicine.

[15]  Q S Xiang,et al.  Chemical shift imaging with spectrum modeling , 2001, Magnetic resonance in medicine.

[16]  Xiaodong Wu,et al.  A rapid 3D fat–water decomposition method using globally optimal surface estimation (R‐GOOSE) , 2018, Magnetic resonance in medicine.

[17]  Jing Yuan,et al.  Max‐IDEAL: A max‐flow based approach for IDEAL water/fat separation , 2014, Magnetic resonance in medicine.

[18]  Håkan Ahlström,et al.  Three‐point dixon method enables whole‐body water and fat imaging of obese subjects , 2010, Magnetic resonance in medicine.

[19]  Diego Hernando,et al.  Robust water/fat separation in the presence of large field inhomogeneities using a graph cut algorithm , 2009, Magnetic resonance in medicine.

[20]  Jingfei Ma,et al.  Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithm , 2004, Magnetic resonance in medicine.

[21]  Chao Zou,et al.  Fat‐water separation using a region‐growing algorithm with self‐feeding phasor estimation , 2017, Magnetic resonance in medicine.