Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter

This paper describes the design and implementation of a discrete controller for grid-connected voltage-source inverters with an LCL filter usually found in wind power generation systems. First, a theorem that relates the controllability of the discrete dynamic equation of the inverter with LCL filter and the sampling frequency is derived. Then, a condition to obtain a partial state feedback controller robust to grid impedance uncertainties and based on linear matrix inequalities is proposed. This controller guarantees the stability and damping of the LCL filter resonance for a large set of grid conditions without requiring self-tuning procedures. Finally, an internal model controller is added to ensure asymptotic reference tracking and disturbance rejection, significantly reducing the impact of grid background voltage distortion on the output currents. Experimental results are presented to support the theoretical analysis and to demonstrate the system performance.

[1]  M. Liserre,et al.  Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier , 2003, IEEE Transactions on Power Electronics.

[2]  Gerard Ledwich,et al.  Connection of inverters to a weak grid , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[3]  P. Mattavelli,et al.  Dissipativity-based adaptive and robust control of UPS in unbalanced operation , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).

[4]  Stephen P. Boyd,et al.  Linear Matrix Inequalities in Systems and Control Theory , 1994 .

[5]  Frede Blaabjerg,et al.  Wind power - a power source now enabled by power electronics , 2007 .

[6]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[7]  H. Pinheiro,et al.  Stability analysis of grid-connected voltage source inverters with LCL-filters using partial state feedback , 2007, 2007 European Conference on Power Electronics and Applications.

[8]  E. Yaz Linear Matrix Inequalities In System And Control Theory , 1998, Proceedings of the IEEE.

[9]  Paolo Mattavelli,et al.  An Adaptive Control for UPS to Compensate Unbalance and Harmonic Distortion Using a Combined Capacitor/Load Current Sensing , 2007, IEEE Transactions on Industrial Electronics.

[10]  Humberto Pinheiro,et al.  New Synchronization Method For Three-phase Three-wire Pwm Converters Under Unbalanced And Distorted Grid Voltages , 2006 .

[11]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[12]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[13]  Zhihong Ye,et al.  Output filter design for a grid-interconnected three-phase inverter , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[14]  K. Uhlen,et al.  Wind turbines in weak grids-constraints and solutions , 2001 .

[15]  M. Liserre,et al.  Multiple harmonics control for three-phase grid converter systems with the use of PI-RES current controller in a rotating frame , 2006, IEEE Transactions on Power Electronics.

[16]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[17]  Ramon Costa-Castelló,et al.  On preserving passivity in sampled-data linear systems , 2005, 2006 American Control Conference.

[18]  J. Svensson,et al.  Control of a voltage-source converter connected to the grid through an LCL-filter-application to active filtering , 1998, PESC 98 Record. 29th Annual IEEE Power Electronics Specialists Conference (Cat. No.98CH36196).

[19]  Enric Fossas,et al.  On preserving passivity in sampled-data linear systems by using state observers , 2006, 2007 European Control Conference (ECC).

[20]  Chi-Tsong Chen,et al.  Linear System Theory and Design , 1995 .

[21]  Humberto Pinheiro,et al.  Discrete-time internal model controller for three-phase PWM inverters with insulator transformer , 2006 .

[22]  Valter J. S. Leite,et al.  Discrete-time switched systems: pole location and structural constrained control , 2003, 42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475).

[23]  Marco Liserre,et al.  New Positive-sequence Voltage Detector for Grid Synchronization of Power Converters under Faulty Grid Conditions , 2006 .

[24]  F. Blaabjerg,et al.  Power electronics as efficient interface in dispersed power generation systems , 2004, IEEE Transactions on Power Electronics.

[25]  P. Lundsager,et al.  Integration of wind power in the power system , 2002, IEEE 2002 28th Annual Conference of the Industrial Electronics Society. IECON 02.