Multi-Angle Plasma Focused Ion Beam (FIB) Curtaining Artifact Correction Using a Fourier-Based Linear Optimization Model

We present a flexible linear optimization model for correcting multi-angle curtaining effects in plasma focused ion beam scanning electron microscopy (PFIB-SEM) images produced by rocking-polishing schemes. When PFIB-SEM is employed in a serial sectioning tomography workow, it is capable of imaging large three-dimensional volumes quickly, providing rich information in the critical 10-100 nm feature length scale. During tomogram acquisition, a "rocking polish" is often used to reduce straight-line "curtaining" gradations in the milled sample surface. While this mitigation scheme is effective for deep curtains, it leaves shallower line artifacts at two discretized angles. Segmentation and other automated processing of the image set requires that these artifacts be corrected for accurate microstructural quantification. Our work details a new Fourier-based linear optimization model for correcting curtaining artifacts by targeting curtains at two discrete angles. We demonstrate its capabilities by processing images from a tomogram from a multiphase, heterogeneous concrete sample. We present methods for selecting the parameters which meet the user's goals most appropriately. Compared to previous works, we show that our model provides effective multi-angle curtain correction without introducing artifacts into the image, modifying non-curtain structures or causing changes to the contrast of voids. Our algorithm can be easily parallelized to take advantage of multi-core hardware.

[1]  M. Curtis,et al.  Microstructural investigation of gas shales in two and three dimensions using nanometer-scale resolution imaging , 2012 .

[2]  P. Munroe,et al.  The effect of the gold sputter-coated films in minimising damage in FIB-produced TEM specimens , 2003 .

[3]  B. Münch,et al.  Stripe and ring artifact removal with combined wavelet--Fourier filtering. , 2009, Optics express.

[4]  Shu‐wen W. Chen,et al.  DeStripe: frequency-based algorithm for removing stripe noises from AFM images , 2011, BMC Structural Biology.

[5]  H. King,et al.  Nano-Tomography of Porous Geological Materials Using Focused Ion Beam-Scanning Electron Microscopy , 2016 .

[6]  D. Adams,et al.  Effects of evolving surface morphology on yield during focused ion beam milling of carbon , 2005 .

[7]  Jian Guo Liu,et al.  FFT Selective and Adaptive Filtering for Removal of Systematic Noise in ETM+ Imageodesy Images , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[8]  Lorenz Holzer,et al.  Advances in 3D focused ion beam tomography , 2014 .

[9]  R. Marc Bustin,et al.  Characterization of gas shale pore systems by porosimetry, pycnometry, surface area, and field emission scanning electron microscopy/transmission electron microscopy image analyses: Examples from the Barnett, Woodford, Haynesville, Marcellus, and Doig units , 2012 .

[10]  Emmanuelle Gouillart,et al.  scikit-image: image processing in Python , 2014, PeerJ.

[11]  Dianne P. O'Leary,et al.  The Use of the L-Curve in the Regularization of Discrete Ill-Posed Problems , 1993, SIAM J. Sci. Comput..

[12]  P. Kotula,et al.  Focused ion beam and scanning electron microscopy for 3D materials characterization , 2014 .

[13]  N. Otsu A threshold selection method from gray level histograms , 1979 .

[14]  Yi Chang,et al.  Robust destriping method with unidirectional total variation and framelet regularization. , 2013, Optics express.

[15]  P. Munroe,et al.  The application of FIB milling for specimen preparation from crystalline germanium. , 2004, Micron.

[16]  Jan Henrik Fitschen,et al.  Removal of curtaining effects by a variational model with directional forward differences , 2015, Comput. Vis. Image Underst..

[17]  T. Ohnishi,et al.  Improvements in performance of focused ion beam cross-sectioning: aspects of ion-sample interaction. , 2004, Journal of electron microscopy.

[18]  M. G. Burke,et al.  Large volume serial section tomography by Xe Plasma FIB dual beam microscopy. , 2016, Ultramicroscopy.

[19]  J. Cairney,et al.  Redeposition effects in transmission electron microscope specimens of FeAl-WC composites prepared using a focused ion beam. , 2003, Micron.

[20]  M. Curtis,et al.  Structural Characterization of Gas Shales on the Micro- and Nano-Scales , 2010 .

[21]  R. Wirth,et al.  Focused Ion Beam (FIB) combined with SEM and TEM: Advanced analytical tools for studies of chemical composition, microstructure and crystal structure in geomaterials on a nanometre scale , 2009 .

[22]  Limin Yang,et al.  Oblique striping removal in remote sensing imagery based on wavelet transform , 2006 .

[23]  Correlative XRM and FIB-SEM for Non/Organic Pore Network Characterization in Woodford Shale Rock Matrix , 2015 .

[24]  Saïd Ladjal,et al.  Toward Optimal Destriping of MODIS Data Using a Unidirectional Variational Model , 2011, IEEE Transactions on Geoscience and Remote Sensing.