Study of Fault Current Characteristics of the DFIG Considering Dynamic Response of the RSC

During nonsevere fault conditions, the crowbar protection is not activated and the rotor windings of a doubly fed induction generator (DFIG) are still excited by the ac/dc/ac converter. In these cases, the dynamic response of a rotor-side converter (RSC) has a large influence on the fault current characteristics of the DFIG. In this paper, an analysis method for the fault current characteristics of the DFIG under nonsevere fault conditions is proposed. First, the dynamic response of the RSC is analyzed on condition that the external power control loop is shut down and the reference signals of the inner rotor current control loop are kept constant. Then, the simplified calculation models of the rotor fault current are established according to different design principles of the inner rotor current controller. Based on it, the fault characteristics of the stator current are studied and the analytical expressions of the stator fault current are obtained. Finally, digital simulation results validate the analytical results. The proposed analysis method is applicable for the study of fault current characteristics of DFIG with different control strategies for low-voltage ride through. The research results are helpful to the construction of adequate relaying protection for the power grid with penetration of DFIGs.

[1]  Werner Leonhard,et al.  Control of Electrical Drives , 1990 .

[2]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[3]  O. Anaya-Lara,et al.  Control of DFIG-based wind generation for power network support , 2005, IEEE Transactions on Power Systems.

[4]  G. Joos,et al.  Effect of low voltage ride through (LVRT) characteristic on voltage stability , 2005, IEEE Power Engineering Society General Meeting, 2005.

[5]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[6]  Peter Tavner,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006 .

[7]  Zhang Jian-hua Operation Control and Modeling-Simulation of AC-excited Variable-speed Constant-frequency(AEVSCF) Wind Power Generator , 2006 .

[8]  P. Sanchis,et al.  Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips , 2007, IEEE Transactions on Energy Conversion.

[9]  J. Morren,et al.  Short-Circuit Current of Wind Turbines With Doubly Fed Induction Generator , 2007, IEEE Transactions on Energy Conversion.

[10]  Hui Li,et al.  An Improved Control Strategy of Limiting the DC-Link Voltage Fluctuation for a Doubly Fed Induction Wind Generator , 2008, IEEE Transactions on Power Electronics.

[11]  Xu Cai,et al.  Dynamic Responses of DFIG Fault Currents Under Constant AC Exitation Condition , 2009, 2009 Asia-Pacific Power and Energy Engineering Conference.

[12]  G Pannell,et al.  Analytical Study of Grid-Fault Response of Wind Turbine Doubly Fed Induction Generator , 2010, IEEE Transactions on Energy Conversion.

[13]  Wilfried Hofmann,et al.  Modeling and Ride-Through Control of Doubly Fed Induction Generators During Symmetrical Voltage Sags , 2011, IEEE Transactions on Energy Conversion.

[14]  Yong Kang,et al.  An Improved Low-Voltage Ride-Through Control Strategy of Doubly Fed Induction Generator During Grid Faults , 2011, IEEE Transactions on Power Electronics.

[15]  Zhang Yigong Dynamic Characteristics of Stator Flux of Doubly-fed Induction Generator During Grid Voltage Fault , 2011 .

[16]  Gang Wang,et al.  Equivalent Model for Calculating Short Circuit Current of Doubly Fed Wind Generator under Uninterrupted Excitation , 2011, 2011 Asia-Pacific Power and Energy Engineering Conference.

[17]  W. Marsden I and J , 2012 .

[18]  G. D. Marques,et al.  Understanding the Doubly Fed Induction Generator During Voltage Dips , 2012, IEEE Transactions on Energy Conversion.

[19]  D. F. Howard,et al.  Improved Sequence Network Model of Wind Turbine Generators for Short-Circuit Studies , 2012, IEEE Transactions on Energy Conversion.

[20]  Xiangping Kong,et al.  Study on Fault Current of DFIG during Slight Fault Condition , 2013 .