Combining dual-tree complex wavelets and multiresolution in iterative CT reconstruction with application to metal artifact reduction

BackgroundThis paper investigates the benefits of data filtering via complex dual wavelet transform for metal artifact reduction (MAR). The advantage of using complex dual wavelet basis for MAR was studied on simulated dental computed tomography (CT) data for its efficiency in terms of noise suppression and removal of secondary artifacts. Dual-tree complex wavelet transform (DT-CWT) was selected due to its enhanced directional analysis of image details compared to the ordinary wavelet transform. DT-CWT was used for multiresolution decomposition within a modified total variation (TV) regularized inversion algorithm.MethodsIn this study, we have tested the multiresolution TV (MRTV) approach with DT-CWT on a 2D polychromatic jaw phantom model with Gaussian and Poisson noise. High noise and sparse measurement settings were used to assess the performance of DT-CWT. The results were compared to the outcome of the single-resolution reconstruction and filtered back-projection (FBP) techniques as well as reconstructions with Haar wavelet basis.ResultsThe results indicate that filtering of wavelet coefficients with DT-CWT effectively removes the noise without introducing new artifacts after inpainting. Furthermore, adoption of multiple resolution levels yield to a more robust algorithm compared to varying the regularization strength.ConclusionsThe multiresolution reconstruction with DT-CWT is also more robust when reconstructing the data with sparse projections compared to the single-resolution approach and Haar wavelets.

[1]  A. Haar Zur Theorie der orthogonalen Funktionensysteme , 1910 .

[2]  Ingrid Daubechies,et al.  Ten Lectures on Wavelets , 1992 .

[3]  Cheng-Hsun Lin,et al.  Quantitative assessment of three vendor’s metal artifact reduction techniques for CT imaging using a customized phantom , 2019, Computer assisted surgery.

[4]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[5]  A Gahleitner,et al.  Cone beam CT: a current overview of devices. , 2013, Dento maxillo facial radiology.

[6]  Lingyan Du,et al.  Dual tree complex wavelet transform and Bayesian estimation based denoising of poission-corrupted X-ray images , 2013, 2013 Fourth International Conference on Intelligent Control and Information Processing (ICICIP).

[7]  J. Fessler,et al.  Modelling the physics in the iterative reconstruction for transmission computed tomography , 2013, Physics in medicine and biology.

[8]  N. Kingsbury Image processing with complex wavelets , 1999, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[9]  V. Thavavel,et al.  Regularized Computed Tomography using Complex Wavelets , 2006 .

[10]  J H Siewerdsen,et al.  Technical aspects of dental CBCT: state of the art. , 2015, Dento maxillo facial radiology.

[11]  Zhengrong Liang,et al.  Adaptive-weighted total variation minimization for sparse data toward low-dose x-ray computed tomography image reconstruction , 2012, Physics in medicine and biology.

[12]  Tony F. Chan,et al.  Image processing and analysis - variational, PDE, wavelet, and stochastic methods , 2005 .

[13]  Sampsa Pursiainen Coarse-to-fine reconstruction in linear inverse problems with application to limited-angle computerized tomography , 2008 .

[14]  Charles A. Bouman,et al.  A general framework for nonlinear multigrid inversion , 2005, IEEE Transactions on Image Processing.

[15]  M. Nikolova An Algorithm for Total Variation Minimization and Applications , 2004 .

[16]  A. Farman,et al.  Clinical applications of cone-beam computed tomography in dental practice. , 2006, Journal.

[17]  M. Bertero,et al.  Projected Landweber method and preconditioning , 1997 .

[18]  Joseph Webster Stayman,et al.  Known-component metal artifact reduction (KC-MAR) for cone-beam CT. , 2019, Physics in medicine and biology.

[19]  Yves De Deene,et al.  On the validity of 3D polymer gel dosimetry: III. MRI-related error sources , 2013, Physics in medicine and biology.

[20]  Emmanuel J. Candès,et al.  The curvelet transform for image denoising , 2002, IEEE Trans. Image Process..

[21]  S. Zhao,et al.  X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses , 2000, IEEE Transactions on Medical Imaging.

[22]  Mohamed-Jalal Fadili,et al.  Curvelets and Ridgelets , 2009, Encyclopedia of Complexity and Systems Science.

[23]  H. Bosmans,et al.  Effective dose range for dental cone beam computed tomography scanners. , 2012, European journal of radiology.

[24]  Curtis R. Vogel,et al.  Iterative Methods for Total Variation Denoising , 1996, SIAM J. Sci. Comput..

[25]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[26]  Hui Zhang,et al.  Efficient Metal Artifact Reduction Method Based on Improved Total Variation Regularization , 2013 .

[27]  I. Ibraheem Reduction of artifacts in dental cone beam CT images to improve the three dimensional image reconstruction , 2012 .

[28]  Habib Zaidi,et al.  X-ray CT Metal Artifact Reduction Using Wavelet Domain $L_{0}$ Sparse Regularization , 2013, IEEE Transactions on Medical Imaging.

[29]  Richard Baraniuk,et al.  The Dual-tree Complex Wavelet Transform , 2007 .

[30]  A. Rahmim,et al.  Sparsity constrained sinogram inpainting for metal artifact reduction in x-ray computed tomography , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[31]  Daisuke Kawahara,et al.  Metal artifact reduction techniques for single energy CT and dual-energy CT with various metal materials , 2019, BJR open.

[32]  Konstantin Nikolaou,et al.  Value of CT iterative metal artifact reduction in PET/CT-clinical evaluation in 100 patients. , 2019, The British journal of radiology.

[33]  Tony F. Chan,et al.  Total Variation Wavelet Thresholding , 2007, J. Sci. Comput..

[34]  G. Swennen,et al.  Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. , 2009, International journal of oral and maxillofacial surgery.

[35]  Li Zhang,et al.  Metal artifact reduction in CT images by sinogram TV inpainting , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[36]  Nick Kingsbury,et al.  The dual-tree complex wavelet transform: a new technique for shift invariance and directional filters , 1998 .

[37]  Guillermo Sapiro,et al.  Image inpainting , 2000, SIGGRAPH.