Modular micro robotic instruments for transluminal endoscopic robotic surgery: New perspectives

The paper addresses the benefits and new perspectives in minimally invasive surgery, related to the development of a new generation of surgical robots for natural orifice transluminal endoscopic surgery (NOTES) with snail architecture and variable stiffness actuation. Snail surgical arms have been proposed and are under development for laparoscopic surgery with access to the patients's body through external incisions. The same concept can be transferred to NOTES procedures with the benefit to improve the reach of the organs by the robot and then to shorten the active portion of the snail arm (besides the general benefits of NOTES such as avoiding external scars). The use of variable stiffness actuation (together with the shortening of the arm portion active during the operation) can further improve controllability and safety. The research involves the development of a miniaturized VSA using superelastic alloy, small enough to be embedded in the joints of the arm. The targeted diameter is 6 mm for the first prototype. The new NOTES instruments proposed are expected to carry out surgical tasks in a large and complex workspace, overcoming obstacles and being safe in case of accidental impacts with the surgical environment. The research is carried out in the framework of the Italian Strategic Research Programmes 2008–2012. A detailed description of the project is provided.

[1]  Tobias Ortmaier,et al.  Design requirements for a new robot for minimally invasive surgery , 2004, Ind. Robot.

[2]  M. Sreekumar,et al.  Critical review of current trends in shape memory alloy actuators for intelligent robots , 2007, Ind. Robot.

[3]  Sungchul Kang,et al.  Design of a robot joint with variable stiffness , 2008, 2008 IEEE International Conference on Robotics and Automation.

[4]  Dominiek Reynaerts,et al.  Design of miniature manipulators for integration in a self-propelling endoscope , 2000 .

[5]  John Kenneth Salisbury,et al.  The Intuitive/sup TM/ telesurgery system: overview and application , 2000, Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065).

[6]  Cenk Cavusoglu DESIGN AND CHARACTERIZATION OF A NOVEL HYBRID ACTUATOR USING SHAPE MEMORY ALLOY AND D , 2005 .

[7]  Anders Robertsson,et al.  Flexible force-vision control for surface following using multiple cameras , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[8]  Vincent Hayward,et al.  Design of shape memory alloy actuator with high strain and variable structure control , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[9]  William J. Wilson,et al.  Relative end-effector control using Cartesian position based visual servoing , 1996, IEEE Trans. Robotics Autom..

[10]  D. Burschka,et al.  Dynamic Augmented Reality for Sensory Substitution in Robot-Assisted Surgical Systems , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  François Chaumette,et al.  Visual servo control. I. Basic approaches , 2006, IEEE Robotics & Automation Magazine.

[12]  Antonio Bicchi,et al.  Fast and "soft-arm" tactics [robot arm design] , 2004, IEEE Robotics & Automation Magazine.

[13]  B. Hannaford,et al.  Force controlled and teleoperated endoscopic grasper for minimally invasive surgery-experimental performance evaluation , 1999, IEEE Transactions on Biomedical Engineering.

[14]  Seth Hutchinson,et al.  Visual Servo Control Part I: Basic Approaches , 2006 .

[15]  A. Szold Nitinol: shape-memory and super-elastic materials in surgery , 2005, Surgical Endoscopy And Other Interventional Techniques.

[16]  Vincent Hayward,et al.  Design and comparison of high strain shape memory alloy actuators , 1997, Proceedings of International Conference on Robotics and Automation.

[17]  Tobias Ortmaier,et al.  A Force Controlled Laparoscopic Surgical Robot without Distal Force Sensing , 2004, ISER.

[18]  Mitchell J. H. Lum,et al.  Multidisciplinary Approach for Developing a New Minimally Invasive Surgical Robotic System , 2006, The First IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics, 2006. BioRob 2006..

[19]  Philippe Bidaud,et al.  Surgery grippers for Minimally Invasive Heart Surgery , 2004 .

[20]  Christopher R. Wagner,et al.  The role of force feedback in surgery: analysis of blunt dissection , 2002, Proceedings 10th Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems. HAPTICS 2002.

[21]  Matteo Zoppi,et al.  Snail surgeon: a new robotic system for minimally invasive surgery , 2005, Proceedings of the Fifth International Workshop on Robot Motion and Control, 2005. RoMoCo '05..

[22]  Antonio Bicchi,et al.  Optimization and Fail-Safety Analysis of Antagonistic Actuation for pHRI , 2006, EUROS.

[23]  H. Kuwano,et al.  Laparoscopic surgery update for gastrointestinal malignancy , 2004, Journal of Gastroenterology.

[24]  S. Shankar Sastry,et al.  Laparoscopic telesurgical workstation , 1998, Photonics West - Biomedical Optics.

[25]  F. Cepolina,et al.  Miniature gripping device , 2004 .

[26]  Keith J. Rebello,et al.  Applications of MEMS in surgery , 2004, Proceedings of the IEEE.

[27]  Jaydev P. Desai,et al.  Design, Development, and Testing of an Automated Laparoscopic Grasper with 3-D Force Measurement Capability , 2004, ISMS.

[28]  Antonio Bicchi,et al.  Dealing with the Safety-Performance Tradeoff in Robot Arms Design and Control , 2004 .

[29]  Bernhard Kübler,et al.  Prototype of Instrument for Minimally Invasive Surgery with 6-Axis Force Sensing Capability , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[30]  Septimiu E. Salcudean,et al.  Design and control of a teleoperated microgripper for microsurgery , 1996, Proceedings of IEEE International Conference on Robotics and Automation.

[31]  Damin J. Siler,et al.  Variable stiffness mechanisms with SMA actuators , 1996, Smart Structures.

[32]  Terenziano Raparelli,et al.  Design of a parallel robot actuated by shape memory alloy wires : Special issue on smart materials-fundamentals and applications , 2002 .

[33]  Pradeep K. Khosla,et al.  Improved force control through visual servoing , 1995, Proceedings of 1995 American Control Conference - ACC'95.

[34]  Joris De Schutter,et al.  Integrated Visual Servoing and Force Control - The Task Frame Approach , 2003, Springer Tracts in Advanced Robotics.

[35]  Russell H. Taylor,et al.  A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation , 2003, IEEE Trans. Robotics Autom..

[36]  F Cepolina,et al.  Review of robotic fixtures for minimally invasive surgery , 2004, The international journal of medical robotics + computer assisted surgery : MRCAS.

[37]  Antonio Bicchi,et al.  Variable Stiffness Actuators for Fast and Safe Motion Control , 2003, ISRR.

[38]  Alessandro De Luca,et al.  On the feedback linearization of robots with variable joint stiffness , 2008, 2008 IEEE International Conference on Robotics and Automation.

[39]  B. Hannaford,et al.  Doc at a Distance , 2006, IEEE Spectrum.

[40]  G. Morel,et al.  Impedance based combination of visual and force control , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[41]  Minoru Asada,et al.  Adaptive hybrid control for visual and force servoing in an unknown environment , 1998, IEEE Robotics Autom. Mag..

[42]  John Kenneth Salisbury,et al.  The Black Falcon: a teleoperated surgical instrument for minimally invasive surgery , 1998, Proceedings. 1998 IEEE/RSJ International Conference on Intelligent Robots and Systems. Innovations in Theory, Practice and Applications (Cat. No.98CH36190).

[43]  A. Darzi,et al.  Recent advances in minimal access surgery , 2002, BMJ : British Medical Journal.

[44]  B. Challacombe,et al.  Trends in robotic surgery. , 2005, Journal of endourology.

[45]  Marc O Schurr,et al.  Artificial tactile sensing in minimally invasive surgery – a new technical approach , 2006, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[46]  Vincenzo Lippiello,et al.  Robot Interaction Control Using Force and Vision , 2006, 2006 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[47]  A. Castellanos,et al.  Force Feedback Plays a Significant Role in Minimally Invasive Surgery: Results and Analysis , 2005, Annals of surgery.

[48]  B L Davies,et al.  Active compliance in robotic surgery—the use of force control as a dynamic constraint , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[49]  D. Rattner,et al.  ASGE/SAGES Working Group on Natural Orifice Translumenal Endoscopic Surgery , 2006, Surgical Endoscopy And Other Interventional Techniques.

[50]  Jan Peirs,et al.  A micro optical force sensor for force feedback during minimally invasive robotic surgery , 2003 .

[51]  M. Misra,et al.  Instruments for transluminal laparoscopic surgery or “NOTES” , 2008, Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy.

[52]  Mamoru Mitsuishi,et al.  Development of a dexterous minimally-invasive surgical system with augmented force feedback capability , 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems.