Active Vibration Control of a Multi-Panel Floor Area

Modern structures are increasingly being constructed ever more slender and with longer spans between columns. These aesthetically pleasing designs, however, are more susceptible to high levels of vibration caused by their human occupants. This has led to research into technology, such as active vibration control (AVC), that can significantly reduce vibrations whilst maintaining the slender structural form. Previous research in the area of AVC for human-induced vibrations in floors has focused on single points where the control is located. This paper investigates the effect over the entire area in a multi-panel floor. Simulations are performed on a finite element model of a real office floor with a realistic walking force applied, simulating the in-service conditions of an office environment. The power demand of the active control system is then investigated, in particular, consideration of the trade-off between performance increase and power demand reduction. The benefits of using high feedback gains to control the entire area of this multi-panel floor are shown to be limited. Subsequently, power and cost savings could be realised through the use of reduced gain and/or a switching-off rule.

[1]  Paul Reynolds,et al.  On-off nonlinear active control of floor vibrations , 2010 .

[2]  Stephen Daley,et al.  An H-infinity design approach to the control of human induced vibration in office floor structures , 2013 .

[3]  Paul Reynolds,et al.  Direct Output Feedback and Model-Based Control Approaches for Mitigation of Human-Induced Vibrations in Floors , 2012 .

[4]  Paul Reynolds,et al.  Robust saturated control of human-induced floor vibrations via a proof-mass actuator , 2009 .

[5]  Linda M. Hanagan,et al.  MIMO floor vibration controller design , 2000, Proceedings of the 2000 American Control Conference. ACC (IEEE Cat. No.00CH36334).

[6]  Emma J. Hudson Incorporating Active Control of Human-Induced Vibrations in Floors into Buildings , 2013 .

[7]  Gangbing Song,et al.  Optimal Vibration Control of a Model Frame Structure Using Piezoceramic Sensors and Actuators , 2005 .

[8]  Paul Reynolds,et al.  Reliability of Assessment Criteria for Building Floor Vibrations Under Human Excitation , 2015 .

[9]  Iván M. Díaz,et al.  Acceleration feedback control of human-induced floor vibrations , 2010 .

[10]  Amir Khajepour,et al.  Active Control of Structures Using Energy‐Based LQR Method , 2006, Comput. Aided Civ. Infrastructure Eng..

[11]  Paul Reynolds,et al.  Power Requirements for Active Control of Floor Vibrations , 2013 .

[12]  Paul Reynolds,et al.  Enhancing active vibration control of pedestrian structures using inertial actuators with local feedback control , 2012 .

[13]  Emiliano Pereira,et al.  A comparative study of SISO and MIMO control strategies for floor vibration damping , 2013 .

[14]  Paul Reynolds,et al.  Response-dependent velocity feedback control for mitigation of human-induced floor vibrations , 2009 .

[15]  Linda M. Hanagan Active control of floor vibrations , 1994 .

[16]  Paul Reynolds,et al.  Probability-based prediction of multi-mode vibration response to walking excitation , 2007 .

[17]  Paul Reynolds,et al.  Implications of structural design on the effectiveness of active vibration control of floor structures , 2013 .

[18]  Paul Reynolds,et al.  Exploring efficiencies of SISO, multi-SISO, and MIMO AVC schemes for floor vibration control , 2012, Smart Structures.