Energy-Efficient Long-term Continuous Personal Health Monitoring

Continuous health monitoring using wireless body area networks of implantable and wearable medical devices (IWMDs) is envisioned as a transformative approach to healthcare. Rapid advances in biomedical sensors, low-power electronics, and wireless communications have brought this vision to the verge of reality. However, key challenges still remain to be addressed. The constrained sizes of IWMDs imply that they are designed with very limited processing, storage, and battery capacities. Therefore, there is a very strong need for efficiency in data collection, analysis, storage, and communication. In this paper, we first quantify the energy and storage requirements of a continuous personal health monitoring system that uses eight biomedical sensors: (1) heart rate, (2) blood pressure, (3) oxygen saturation, (4) body temperature, (5) blood glucose, (6) accelerometer, (7) electrocardiogram (ECG), and (8) electroencephalogram (EEG). Our analysis suggests that there exists a significant gap between the energy and storage requirements for long-term continuous monitoring and the capabilities of current devices. To enable energy-efficient continuous health monitoring, we propose schemes for sample aggregation, anomaly-driven transmission, and compressive sensing to reduce the overheads of wirelessly transmitting, storing, and encrypting/authenticating the data. We evaluate these techniques and demonstrate that they result in two to three orders-of-magnitude improvements in energy and storage requirements, and can help realize the potential of long-term continuous health monitoring.

[1]  Charles Sodini,et al.  A long-term wearable electrocardiogram measurement system , 2013, 2013 IEEE International Conference on Body Sensor Networks.

[2]  C. Simon,et al.  Circadian and ultradian variations of leptin in normal man under continuous enteral nutrition: relationship to sleep and body temperature. , 1998, The Journal of clinical endocrinology and metabolism.

[3]  Ingrid Moerman,et al.  A Comprehensive Survey of Wireless Body Area Networks , 2012, Journal of Medical Systems.

[4]  Mun Choon Chan,et al.  Using mobile phone barometer for low-power transportation context detection , 2014, SenSys.

[5]  Wan-Young Chung,et al.  A wireless sensor network compatible wearable u-healthcare monitoring system using integrated ECG, accelerometer and SpO2 , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  Aleksandar Milenkovic,et al.  System architecture of a wireless body area sensor network for ubiquitous health monitoring , 2005 .

[7]  Krzysztof Iniewski,et al.  Ultra-low power 90nm 6T SRAM cell for wireless sensor network applications , 2006, 2006 IEEE International Symposium on Circuits and Systems.

[8]  Ali H. Shoeb,et al.  Application of machine learning to epileptic seizure onset detection and treatment , 2009 .

[9]  S. Aviyente,et al.  Analysis of Event Related Potentials using PCA and Matching Pursuit on the Time-Frequency Plane , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[10]  G. Cauwenberghs,et al.  Wireless multichannel acquisition of neuropotentials , 2008, 2008 IEEE Biomedical Circuits and Systems Conference.

[11]  Sun-Yuan Kung,et al.  Low-energy Formulations of Support Vector Machine Kernel Functions for Biomedical Sensor Applications , 2012, Journal of Signal Processing Systems.

[12]  Rahul Sarpeshkar,et al.  A Bio-Inspired Ultra-Energy-Efficient Analog-to-Digital Converter for Biomedical Applications , 2006, IEEE Transactions on Circuits and Systems I: Regular Papers.

[13]  Yoo-Joo Choi,et al.  SmartBuckle: human activity recognition using a 3-axis accelerometer and a wearable camera , 2008, HealthNet '08.

[14]  Ilias Maglogiannis,et al.  Mobile healthcare information management utilizing Cloud Computing and Android OS , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[15]  Sang-Joong Jung,et al.  A wireless sensor network compatible wearable u-healthcare monitoring system using integrated ECG, accelerometer and SpO2. , 2008, Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference.

[16]  Ian F. Akyildiz,et al.  Sensor Networks , 2002, Encyclopedia of GIS.

[17]  O. Boric-Lubecke,et al.  Analog Signal Processing for Heart Rate Extraction , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[18]  JeongGil Ko,et al.  Wireless Sensor Networks for Healthcare , 2010, Proceedings of the IEEE.

[19]  H V Pipberger,et al.  Distortions in infant electrocardiograms caused by inadequate high-frequency response. , 1977, American heart journal.

[20]  Izmail Batkin,et al.  Sampling Rate of Heart Rate Variability Impacts the Ability to Detect Acidemia in Ovine Fetuses Near-Term , 2014, Front. Pediatr..

[21]  Rekha Jain,et al.  Wireless Sensor Network -A Survey , 2013 .

[22]  Matt Welsh,et al.  CodeBlue: An Ad Hoc Sensor Network Infrastructure for Emergency Medical Care , 2004 .

[23]  D. Spencer,et al.  Complex partial seizures of frontal lobe origin , 1985, Annals of neurology.

[24]  Chacko John Deepu,et al.  An ECG-SoC with 535nW/channel lossless data compression for wearable sensors , 2013, 2013 IEEE Asian Solid-State Circuits Conference (A-SSCC).

[25]  Hoi-Jun Yoo,et al.  A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes , 2010 .

[26]  Katarzyna Wac,et al.  QoS-Predictions Service: Infrastructural Support for Proactive QoS- and Context-Aware Mobile Services (Position Paper) , 2006, OTM Workshops.

[27]  R.G. Carvajal,et al.  A Low-Voltage Low-Power Front-End for Wearable EEG Systems , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  A.P. Chandrakasan,et al.  An Ultra Low Energy 12-bit Rate-Resolution Scalable SAR ADC for Wireless Sensor Nodes , 2007, IEEE Journal of Solid-State Circuits.

[29]  Naveen Verma,et al.  Signal Processing With Direct Computations on Compressively Sensed Data , 2015, IEEE Transactions on Very Large Scale Integration (VLSI) Systems.

[30]  Joshua R. Smith,et al.  Power consumption analysis of Bluetooth Low Energy, ZigBee and ANT sensor nodes in a cyclic sleep scenario , 2013, 2013 IEEE International Wireless Symposium (IWS).

[31]  Ingrid Moerman,et al.  A survey on wireless body area networks , 2011, Wirel. Networks.

[32]  E. Winslow,et al.  Oxygen saturation and hemodynamic response in critically ill, mechanically ventilated adults during intrahospital transport. , 1995, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[33]  Liqing Zhang,et al.  ECG Feature Extraction and Classification Using Wavelet Transform and Support Vector Machines , 2005, 2005 International Conference on Neural Networks and Brain.

[34]  Peter G Davis,et al.  Oxygen saturation in healthy infants immediately after birth. , 2006, The Journal of pediatrics.

[35]  I. Módy,et al.  High-frequency oscillations : What is normal and what is not ? , 2008 .

[36]  Giuseppe Mancia,et al.  Ambulatory Blood Pressure Is Superior to Clinic Blood Pressure in Predicting Treatment-Induced Regression of Left Ventricular Hypertrophy , 1997 .

[37]  Naveen Verma,et al.  A 0.6–107 µW Energy-Scalable Processor for Directly Analyzing Compressively-Sensed EEG , 2014, IEEE Transactions on Circuits and Systems I: Regular Papers.

[38]  P. Laguna,et al.  Impact of Sampling Rate Reduction on Automatic ECG Delineation , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[39]  Alfred O. Hero,et al.  Non-orthogonal Gabor representation of event-related potentials , 1993, Proceedings of the 15th Annual International Conference of the IEEE Engineering in Medicine and Biology Societ.

[40]  Tavakoli Dastjerdi,et al.  An analog VLSI front end for pulse oximetry , 2006 .

[41]  Peter C Laussen,et al.  Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery , 2006, Pediatrics.

[42]  J. Gotman,et al.  High-frequency oscillations during human focal seizures. , 2006, Brain : a journal of neurology.

[43]  Bengt E. Jonsson An empirical approach to finding energy efficient ADC architectures , 2011 .

[44]  Manuel Blanco-Velasco,et al.  Compressed sensing based method for ECG compression , 2011, 2011 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP).

[45]  H Schuster,et al.  [Sensors in medicine]. , 1990, Biomedizinische Technik. Biomedical engineering.

[46]  Veena N. Hegde,et al.  HEART RATE VARIABILITY ANALYSIS FOR ABNORMALITY DETECTION USING TIME FREQUENCY DISTRIBUTION - SMOOTHED PSEUDO WINGER VILLE METHOD , 2013, ICIT 2013.

[47]  K J Blinowska,et al.  A unified time-frequency parametrization of EEGs. , 2001, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[48]  Ying Bai,et al.  An ultra-wearable, wireless, low power ECG monitoring system , 2006, 2006 IEEE Biomedical Circuits and Systems Conference.

[49]  E.J. Candes,et al.  An Introduction To Compressive Sampling , 2008, IEEE Signal Processing Magazine.

[50]  Christopher G. Scully,et al.  The mixing rate of the arterial blood pressure waveform Markov chain is correlated with shock index during hemorrhage in anesthetized swine , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.