In this paper, a new current-mode single-input three-output (SITO) universal filter employing FTFNs and reduced number of passive components is proposed. The circuit contains four FTFNs and five passive components, three of them are grounded. It provides simultaneous realisation of low-pass, band-pass and high-pass filter functions without changing the circuit topology and elements and does not require any parameter matching condition. The proposed circuit enjoys independent control of the parameters *, and <aJQ. Sensitivity analysis of the filter shows that it has tow passive sensitivities; *>, and (aJQ of the filter are insensitive to current tracking errors and tu, of the filter is also insensitive to voltage tracking errors of the FTFNs. High output impedances of the proposed universal filter enable the circuits to be cascaded without requiring any impedance matching device. The theoretical results are confirmed by PSPICE simulations. Übersicht Ein neues Universalfilter vom Stromquellentypus mit einem Eingang und drei Ausgängen (SITO) unter Verwendung von FTFN bei reduzierter Anzahl passiver Komponenten wird vorgeschlagen. Der Schaltkreis enthält vier FTFN sowie fünf passive Komponenten, von denen drei einseitig geerdet sind. Die Anordnung sieht gleichzeitige Realisierung von Tiefpaß-, Bandpaßund Hochpaß-Verhalten ohne Schaltungsänderung vor und stellt keine Nebenbedingungen bezüglich der Schaltungsparameter. Die Größen ob und <aJQ können unabhängig eingestellt werden. Eine niedrige passive Empfindlichkeit wird nachgewiesen, «b, Q und <aJQ des Riters sind unempfindlich gegenüber Stromänderungen, und ob ist außerdem unempfindlich gegenüber Spannungsänderungen der FTFN. Wegen der hohen Ausgangsimpedanzen können die vorgeschlagenen Schaltkreise ohne Anpaßmaßnahmen kaskadiert werden. PSPICE-Simulationen bestätigen die theoretischen Ergebnisse. Für die Dokumentation Signalverarbeitung mit Stromquellen / aktive Filter / FTFN
[1]
Shen-Iuan Liu.
Single-resistance-controlled sinusoidal oscillator using two FTFNs
,
1997
.
[2]
Shen-Iuan Liu.
Cascadable current-mode filters using single FTFN
,
1995
.
[3]
Jiin-Long Lee,et al.
Insensitive current/voltage-mode filters using FTFNs
,
1996
.
[4]
R. Senani.
A novel application of four-terminal floating nullors
,
1987,
Proceedings of the IEEE.
[5]
M. Higashimura,et al.
Current-mode allpass filter using FTFN with grounded capacitor
,
1991
.
[6]
Chien-Kuo Chang,et al.
Single-element controlled oscillators using single FTFN
,
1996
.
[7]
Serdar Ozoguz,et al.
Single-input and three-output current-mode universal filter using a reduced number of active elements
,
1998
.
[8]
Brett Wilson.
Tutorial review Trends in current conveyor and current-mode amplifier design
,
1992
.
[9]
Masami Higashimura.
Current-mode highpass, bandpass and lowpass filters using the operational amplifier pole
,
1993
.
[10]
Muhammad Taher Abuelma'atti,et al.
Novel grounded-capacitor active biquads using FiTFNs
,
1998
.
[11]
Alfonso Carlosena,et al.
Unified approach to the implementations of universal active devices
,
1994
.
[12]
Muhammad Taher Abuelma'atti.
Cascadable current-mode filters using single FTFN
,
1996
.
[13]
Shen-Iuan Liu,et al.
Current-mode quadrature sinusoidal oscillator using single FTFN
,
1996
.