Ground reaction forces on stairs. Part II: knee implant patients versus normals.

The goal of this study was to compare selected parameters of vertical ground reaction forces (GRF) of good outcome patients with different prosthesis designs with a matched control group during level walking, stair ascent and descent. Forty subjects, 29 with three main implant designs (including four subjects with a passive knee flexion restriction), and 11 healthy controls were measured with 8-10 repetitions. Vertical ground reaction forces were measured during two consecutive steps with force plates embedded in the walkway and the staircase. Defined parameters of the force signals were used to compare the results of the test groups. The results show, that, postoperatively, good outcome patients produce gait patterns of the vertical ground reaction force which are comparable to normal healthy subjects with the exception of a few distinct differences: a significant reduction (p<0.05) in the vertical loading on the operated side during level walking at take-off, at weight acceptance and take-off during stair ascent of the normal stair. During stair descent, the patients did not reduce load on the operated side, but increased load variation and side-to-side asymmetry; thus, the mechanical loads on the implants were high, which may be important information with respect to loading protocols of knee implant simulators. No systematic differences in any of the test parameters were found between posterior cruciate-retaining (LCS MB and Innex CR) versus non-retaining (LCS RP and Innex UCOR) implant designs. The restricted group showed significant reductions (p<0.05) of several loading parameters as well as an increased side-to-side asymmetry. About one third of the force parameters of the good outcome patients showed a side-to-side asymmetry between two consecutive steps, which was over a proposed level of acceptance.

[1]  Christopher L. Vaughan,et al.  Mounting and calibration of stairs on piezoelectric force platforms , 1993 .

[2]  C L Vaughan,et al.  Anterior cruciate ligament reconstruction and joint dynamics during stair climbing. , 1997, Medicine and science in sports and exercise.

[3]  R. Riener,et al.  Stair ascent and descent at different inclinations. , 2002, Gait & posture.

[4]  N. Stergiou,et al.  Nonlinear dynamics indicates aging affects variability during gait. , 2003, Clinical biomechanics.

[5]  M. Harman,et al.  Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator , 2002, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[6]  B. Nigg,et al.  Asymmetries in ground reaction force patterns in normal human gait. , 1989, Medicine and science in sports and exercise.

[7]  L. Dorr,et al.  Rationale of the Knee Society clinical rating system. , 1989, Clinical orthopaedics and related research.

[8]  H. U. Debrunner,et al.  Parameter-Analyse des menschlichen Ganges , 1980 .

[9]  F Catani,et al.  Muscle activation pattern and gait biomechanics after total knee replacement. , 2003, Clinical biomechanics.

[10]  Alex Stacoff,et al.  Ground reaction forces on stairs: effects of stair inclination and age. , 2005, Gait & posture.

[11]  S. Giannini,et al.  Mobile and fixed bearing total knee prosthesis functional comparison during stair climbing. , 2003, Clinical biomechanics.

[12]  E S Growney,et al.  Reproducibility of the kinematics and kinetics of the lower extremity during normal stair‐climbing , 1997, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[13]  J Perry,et al.  Functional comparison of posterior cruciate-retained versus cruciate-sacrificed total knee arthroplasty. , 1988, Clinical orthopaedics and related research.

[14]  T. M. Owings,et al.  A biomechanical evaluation of one-stage vs two-stage bilateral knee arthroplasty patients. , 1999, Gait & posture.

[15]  G. Giakas,et al.  Time and frequency domain analysis of ground reaction forces during walking: an investigation of variability and symmetry , 1997 .

[16]  Benjamin J. Fregly,et al.  Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements , 2005, Knee Surgery, Sports Traumatology, Arthroscopy.

[17]  Kathryn A. Christina,et al.  Ground reaction forces and frictional demands during stair descent: effects of age and illumination. , 2002, Gait & posture.

[18]  J L McCrory,et al.  Vertical ground reaction forces: objective measures of gait following hip arthroplasty. , 2001, Gait & posture.

[19]  K. An,et al.  Gait characteristics of patients with knee osteoarthritis. , 2001, Journal of biomechanics.

[20]  R. N. Stauffer,et al.  Normative data of knee joint motion and ground reaction forces in adult level walking. , 1983, Journal of biomechanics.

[21]  J. Archea,et al.  Environmental factors associated with stair accidents by the elderly. , 1985, Clinics in geriatric medicine.

[22]  W. Norman Scott,et al.  Surgery of the knee , 2001 .

[23]  M A Ritter,et al.  Gait laboratory analysis of a posterior cruciate-sparing total knee arthroplasty in stair ascent and descent. , 1989, Clinical orthopaedics and related research.

[24]  R. White,et al.  The variability of force platform data in normal and cerebral palsy gait. , 1999, Clinical biomechanics.

[25]  T. Andriacchi Dynamics of pathological motion: applied to the anterior cruciate deficient knee. , 1990, Journal of biomechanics.

[26]  T. Andriacchi,et al.  The influence of total knee-replacement design on walking and stair-climbing. , 1982, The Journal of bone and joint surgery. American volume.

[27]  E Stüssi,et al.  Quantitative gait analysis after bilateral total knee arthroplasty with two different systems within each subject. , 1997, The Journal of arthroplasty.

[28]  S A Banks,et al.  In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties. , 1997, The Journal of arthroplasty.

[29]  T P Andriacchi,et al.  Walking speed as a basis for normal and abnormal gait measurements. , 1977, Journal of biomechanics.

[30]  Motoki Kouzaki,et al.  Variability of ground reaction forces during treadmill walking. , 2002, Journal of applied physiology.

[31]  P. Riley,et al.  Biomechanical analysis of body mass transfer during stair ascent and descent of healthy subjects. , 1993, Journal of rehabilitation research and development.