Practical considerations for image-based PSF and blobs reconstruction in PET
暂无分享,去创建一个
[1] E. Veklerov,et al. MLE reconstruction of a brain phantom using a Monte Carlo transition matrix and a statistical stopping rule , 1988 .
[2] S. Ross,et al. Properties and Mitigation of Edge Artifacts in PSF-Based PET Reconstruction , 2011, IEEE Transactions on Nuclear Science.
[3] C. Comtat,et al. Monte Carlo Simulation for the ECAT EXACT HR+ system using GATE , 2003, IEEE Transactions on Nuclear Science.
[4] Kris Thielemans,et al. Trade-off between contrast recovery, image noise and edge artifacts in PET image reconstruction using detector blurring models , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.
[5] Andrew J. Reader,et al. Impact of Image-Space Resolution Modeling for Studies with the High-Resolution Research Tomograph , 2008, Journal of Nuclear Medicine.
[6] M Defrise,et al. Non-Gaussian space-variant resolution modelling for list-mode reconstruction , 2010, Physics in medicine and biology.
[7] S Stute,et al. GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy , 2011, Physics in medicine and biology.
[8] R. Lewitt. Alternatives to voxels for image representation in iterative reconstruction algorithms , 1992, Physics in medicine and biology.
[9] A. Rahmim,et al. Space-variant and anisotropic resolution modeling in list-mode EM reconstruction , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).
[10] L. J. Thomas,et al. Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography , 1987, IEEE Transactions on Medical Imaging.
[11] Johan Nuyts,et al. Image properties of various ML-based reconstructions of very noisy HRRT data , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.
[12] Peter D. Esser,et al. The effect of edge artifacts on quantification of Positron Emission Tomography , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.
[13] V. Bettinardi,et al. Evaluation of a New Regularization Prior for 3-D PET Reconstruction Including PSF Modeling , 2012, IEEE Transactions on Nuclear Science.
[14] Jack Bresenham,et al. Algorithm for computer control of a digital plotter , 1965, IBM Syst. J..
[15] Yuchen Yan,et al. A system for the 3D reconstruction of retracted-septa PET data using the EM algorithm , 1994, Proceedings of 1994 IEEE Nuclear Science Symposium - NSS'94.
[16] Vladimir Y. Panin,et al. Fully 3-D PET reconstruction with system matrix derived from point source measurements , 2006, IEEE Transactions on Medical Imaging.
[17] Paul Kinahan,et al. Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation , 2010, Physics in medicine and biology.
[18] Arman Rahmim,et al. Analytic system matrix resolution modeling in PET: An application to Rb-82 cardiac imaging , 2008, ISBI.
[19] Andrew J. Reader,et al. EM algorithm system modeling by image-space techniques for PET reconstruction , 2003 .
[20] K Thielemans,et al. Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET , 2010, Physics in medicine and biology.
[21] Claude Comtat,et al. Normalization of Monte Carlo PET data using GATE , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.
[22] A. Martineau,et al. A method for accurate modelling of the crystal response function at a crystal sub-level applied to PET reconstruction , 2011, Physics in medicine and biology.
[23] L.M. Popescu,et al. Ray tracing through a grid of blobs , 2004, IEEE Symposium Conference Record Nuclear Science 2004..
[24] Gabor T. Herman,et al. Image reconstruction from projections : the fundamentals of computerized tomography , 1980 .
[25] C. Byrne. Iterative algorithms for deblurring and deconvolution with constraints , 1998 .
[26] Johan Nuyts,et al. Maximum-likelihood reconstruction based on a modified Poisson distribution to reduce bias in PET , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.
[27] R. Leahy,et al. High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner. , 1998, Physics in medicine and biology.
[28] Klaus Wienhard,et al. The ECAT HRRT: performance and first clinical application of the new high resolution research tomograph , 2000 .
[29] M. Rafecas,et al. Use of a Monte Carlo-based probability matrix for 3-D iterative reconstruction of MADPET-II data , 2004, IEEE Transactions on Nuclear Science.
[30] P. Joseph. An Improved Algorithm for Reprojecting Rays through Pixel Images , 1982 .
[31] K Thielemans,et al. Impact of PSF modelling on the convergence rate and edge behaviour of EM images in PET , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.
[32] Andrew J. Reader,et al. One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays , 2002 .
[33] Michael E Casey,et al. PET performance measurements using the NEMA NU 2-2001 standard. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[34] H. Malcolm Hudson,et al. Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.
[35] D. Snyder,et al. Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography. , 1991, IEEE transactions on medical imaging.
[36] R M Lewitt,et al. Multidimensional digital image representations using generalized Kaiser-Bessel window functions. , 1990, Journal of the Optical Society of America. A, Optics and image science.
[37] L. Shepp,et al. Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.
[38] Jinyi Qi,et al. Iterative reconstruction techniques in emission computed tomography , 2006, Physics in medicine and biology.
[39] P. Joseph. An Improved Algorithm for Reprojecting Rays through Pixel Images , 1983, IEEE Transactions on Medical Imaging.
[40] Samuel Matej,et al. Efficient 3D grids for image reconstruction using spherically-symmetric volume elements , 1995 .
[41] R. Siddon. Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.
[42] B. De Man,et al. Distance-driven projection and backprojection in three dimensions. , 2004, Physics in medicine and biology.
[43] Pablo Aguiar,et al. Geometrical and Monte Carlo projectors in 3D PET reconstruction. , 2010, Medical physics.
[44] Gengsheng L Zeng. Gibbs Artifact Reduction by Nonnegativity Constraint , 2011, The Journal of Nuclear Medicine Technology.
[45] Jürgen Scheins,et al. Analytical calculation of volumes-of-intersection for iterative, fully 3-D PET reconstruction , 2006, IEEE Transactions on Medical Imaging.