Liquid Chromatographic Determination of a Substituted Benzamide in Biological Fluids Using Preconcentration and Post-Column Extraction

Abstract A sensitive and selective semi-automated method has been developed for the determination of Remoxipride in biological fluids. The chromatographic behaviour of the basic drug is strongly improved by treatment of the C-18 bonded column with hexadecyltrimethylammonium bromide. The use of disposable precolumns permits the direct injection of 1:1 (v/v) diluted plasma or 1:9 (v/v) diluted urine. For detection, a post-column ion-pair extraction with the strongly fluorescent 9,10-dimethoxyanthracene-2-sulphonate was used. A new sandwich type phase separator helped to keep band broadening very low. The calibration curves of Remoxipride in plasma and urine show correlation coefficients of 0.9999 over at least two orders of magnitude. Detection limits are 1 ng/ml in plasma and 15 ng/ml in urine. The recovery of Remoxipride from spiked plasma and urine is 88% and 76%, respectively. The reproducibility, based on peak height measurements, for determinations in plasma (200 ng/ml) was 3.5% (RSD) within one seria...

[1]  R. W. Frei,et al.  Liquid chromatographic determination of a quaternary ammonium-steroidal type drug in plasma with post-column extraction. , 1986, Journal of pharmaceutical and biomedical analysis.

[2]  R. W. Frei,et al.  Automated pre-column system for trace enrichment and clean-up of plasma samples in narrow-bore liquid chromatography , 1985 .

[3]  S. Morgan,et al.  Effects of amine modifiers on retention and peak shape in reversed-phase high-performance liquid chromatography , 1985 .

[4]  M. Snoussi,et al.  High-performance liquid chromatographic determination of a new benzamide in biological fluids for use in a human pharmacokinetic study. , 1985, Journal of chromatography.

[5]  H. Hall,et al.  Remoxipride, a new potential antipsychotic compound with selective antidopaminergic actions in the rat brain. , 1984, European journal of pharmacology.

[6]  R. W. Frei,et al.  Automated liquid chromatographic analysis of the anti-tumorigenic drugs etoposide (VP 16-213) and teniposide (VM 26). , 1983, Journal of chromatography.

[7]  R. W. Frei,et al.  Sample extraction detector for the liquid chromatographic determination of secoverine in biological samples. , 1981, Journal of chromatography.

[8]  R. W. Frei,et al.  Continuous post-column ion-pair extraction detection of some basic organic compounds in normal-phase chromatography , 1979 .

[9]  J. F. Lawrence,et al.  Extraction detector for high-performance liquid chromatography using solvent segmentation of the column effluent , 1979 .