Electrochemical investigation of endotoxin induced limulus amebocyte lysate gel-clot process

Endotoxin can interact with specific receptors on immune cells, leading to inflammatory responses. Thus, it should be strictly controlled in medical devices and pharmaceuticals. The standard endotoxin assay is based on limulus amebocyte lysate (LAL). Herein, we have successfully characterized the electrochemical behavior of endotoxin induced limulus amebocyte lysate gel-clot process for the first time. Screen-printed electrodes with high stability, convenient operation, low cost are produced for the electrochemical investigation. The electrochemical signals of gel-clot process are then applied to endotoxin assay. Compared with other assays, our proposed electrochemical method has faster responses and is more sensitive, anti-jamming and cost-effective, which might have potential use in the clinical applications in the future.

[1]  S. Srivatsan,et al.  Label-free fluorescence detection of the depurination activity of ribosome inactivating protein toxins. , 2012, Chemical communications.

[2]  J. Douwes,et al.  Interlaboratory evaluation of endotoxin analyses in agricultural dusts--comparison of LAL assay and mass spectrometry. , 2005, Journal of environmental monitoring : JEM.

[3]  B. Beutler,et al.  How we detect microbes and respond to them: the Toll‐like receptors and their transducers , 2003, Journal of leukocyte biology.

[4]  M. Apicella,et al.  The lipooligosaccharides of pathogenic gram-negative bacteria. , 1996, Critical reviews in microbiology.

[5]  H. S. Warren,et al.  Turbidimetric method for quantifying serum inhibition of Limulus amoebocyte lysate , 1985, Journal of clinical microbiology.

[6]  M. Mascini,et al.  An ELIME assay for the rapid diagnosis of coeliac disease , 2012, Analytical and Bioanalytical Chemistry.

[7]  C. Raetz,et al.  Biochemistry of endotoxins. , 1990, Annual review of biochemistry.

[8]  Kumi Y. Inoue,et al.  Electrochemical monitoring of hydrogen peroxide released from leucocytes on horseradish peroxidase redox polymer coated electrode chip. , 2010, Biosensors & bioelectronics.

[9]  Juan Tang,et al.  Carbon nanotube-based symbiotic coaxial nanocables with nanosilica and nanogold particles as labels for electrochemical immunoassay of carcinoembryonic antigen in biological fluids. , 2011, Talanta.

[10]  Allen J. Bard,et al.  Electrochemical Methods: Fundamentals and Applications , 1980 .

[11]  K. Tracey,et al.  Vagus nerve stimulation attenuates the systemic inflammatory response to endotoxin , 2000, Nature.

[12]  Peng Chen,et al.  Detecting metabolic activities of bacteria using a simple carbon nanotube device for high-throughput screening of anti-bacterial drugs. , 2011, Biosensors & bioelectronics.

[13]  Günther Jung,et al.  A fluorescence-based synthetic LPS sensor. , 2007, Journal of the American Chemical Society.

[14]  A. Douvdevani,et al.  Gel clot LAL assay in the initial management of peritoneal dialysis patients with peritonitis: a retrospective study. , 2000, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[15]  Guonan Chen,et al.  An aptamer-based fluorescence biosensor for multiplex detection using unmodified gold nanoparticles. , 2012, Chemical communications.

[16]  Peng Miao,et al.  Functionalization of platinum nanoparticles for electrochemical detection of nitrite , 2011, Analytical and bioanalytical chemistry.

[17]  S. Iwanaga Biochemical principle of Limulus test for detecting bacterial endotoxins , 2007, Proceedings of the Japan Academy. Series B, Physical and biological sciences.

[18]  P. Martin,et al.  Automation of chromogenic substrate Limulus amebocyte lysate assay method for endotoxin by robotic system , 1984, Applied and environmental microbiology.

[19]  Pengfei Wang,et al.  Sensing of bacterial endotoxin in aqueous solution by supramolecular assembly of pyrene derivative. , 2010, Organic letters.

[20]  F. Battaglini,et al.  Surfactant-assisted lipopolysaccharide conjugation employing a cyanopyridinium agent and its application to a competitive assay. , 2009, Analytical chemistry.

[21]  Hitoshi Shiku,et al.  Development of an electrochemical Limulus amebocyte lysate assay technique for portable and highly sensitive endotoxin sensor , 2012, Innate immunity.

[22]  Byung-Gee Kim,et al.  Screening of LPS-specific peptides from a phage display library using epoxy beads. , 2005, Biochemical and biophysical research communications.

[23]  Hao Li,et al.  Exonuclease III-based and gold nanoparticle-assisted DNA detection with dual signal amplification. , 2012, Biosensors & bioelectronics.

[24]  G. Hu,et al.  Innate Immune Function of the Adherens Junction Protein p120-Catenin in Endothelial Response to Endotoxin , 2011, The Journal of Immunology.

[25]  M. Kunitake,et al.  Selective assay for endotoxin using poly(epsilon-lysine)-immobilized Cellufine and Limulus amoebocyte lysate (LAL). , 2009, Analytical biochemistry.

[26]  F. Battaglini,et al.  Use of an antimicrobial protein for endotoxin detection in a competitive electrochemical assay. , 2005, Analytical chemistry.

[27]  K. Tracey,et al.  Globin Attenuates the Innate Immune Response to Endotoxin , 2002, Shock.

[28]  A. Lepape,et al.  Detection of gram‐negative bacteraemia in early sepsis by a quantitative chromogenic and kinetic endotoxin assay , 1996, European journal of clinical investigation.

[29]  Hitoshi Shiku,et al.  Electrochemical detection of endotoxin using recombinant factor C zymogen , 2010 .