Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients

ObjectiveComparison of oscillometric blood pressure measurement with two different devices (M3000A using a new algorithm and M1008A using an established algorithm, both Hewlett Packard) and evaluation of current recommendations concerning the relation between cuff size and upper arm circumference in critically ill patients. DesignProspective data collection. SettingEmergency department in a 2000-bed inner-city hospital. PatientsA total of 30 patients categorized into three groups according to their upper arm circumference (I, 18–25 cm; II, 25.1–33 cm; III, 33.1–47.5 cm) were enrolled in the study protocol. InterventionsIn each patient, two noninvasive blood pressure devices with three different cuff sizes were used to perform oscillometric blood pressure measurement. Invasive mean arterial blood pressure measurement was done by cannulation of the radial artery. Measurement and Main ResultsOverall, 1,011 pairs of simultaneous oscillometric and invasive blood pressure measurements were collected in 30 patients (group I, n = 10; group II, n = 10; group III, n = 10). The overall discrepancy between both methods with the M3000A was −2.4 ± 11.8 mm Hg (p < .0001) and, with the M1008A, −5.3 ± 11.6 mm Hg (p < .0001) if the recommended cuff size according to the upper arm circumference was used (352 measurements). If smaller cuff sizes than recommended were used (308 measurements performed in group II and III), the overall discrepancy between both methods with the M3000A was 1.3 ± 13.4 mm Hg (p < .024) and, with the M1008A, −2.3 ± 11.5 mm Hg (p < .0001). ConclusionThe new algorithm reduced the overall bias of the oscillometric method but still showed a significant discrepancy between both methods of blood pressure measurement, primarily due to the mismatch between upper arm circumference and cuff size. The improvement of the algorithm alone could not result in a sufficient improvement of oscillometric blood pressure measurement. A reevaluation of the recommendations concerning the relation between upper arm circumference and cuff size are urgently required if oscillometric blood pressure measurement should become a reasonable alternative to intra-arterial blood pressure measurement in critically ill patients.

[1]  C. Prys‐roberts Cardiovascular monitoring in patients with vascular disease. , 1981, British journal of anaesthesia.

[2]  S Slogoff,et al.  On the Safety of Radial Artery Cannulation , 1983, Anesthesiology.

[3]  M M Hirschl,et al.  Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients. , 1996, Critical care medicine.

[4]  M M Hirschl,et al.  Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper‐arm circumference in critically ill patients , 2000, Critical care medicine.

[5]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[6]  K. Yamakoshi,et al.  Hypertensive episodes and circadian fluctuations of blood pressure in patients with phaeochromocytoma: studies by long-term blood pressure monitoring based on a volume-oscillometric method. , 1988, Journal of hypertension.

[7]  A. Treloar,et al.  Circulation A Journal of the American-Heart Association Comparison of Indirect and Direct Methods of Measuring Arterial Blood Pressure , 2005 .

[8]  A comparison of two automated indirect arterial blood pressure meters: with recordings from a radial arterial catheter in anesthetized surgical patients. , 1985, Anesthesiology.

[9]  C. Goodman Association for the Advancement of Medical Instrumentation , 1988 .

[10]  B. Lösse,et al.  Non-invasive oscillometric wrist and upper arm blood pressure measurements compared with invasive values. , 1996, Zeitschrift fur Kardiologie.

[11]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[12]  R. F. McEllistrem,et al.  Post-cannulation radial artery aneurysm — a rare complication , 1990, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[13]  J. Kerr,et al.  Arterial occlusion after cannulation. , 1975, British medical journal.

[14]  J. Derr,et al.  The accuracy of Finapres noninvasive mean arterial pressure measurements in anesthetized patients. , 1991, Anesthesiology.

[15]  D. Chyun A comparison of intra-arterial and auscultatory blood pressure readings. , 1985, Heart & lung : the journal of critical care.

[16]  J. Reidy,et al.  Blood pressure measurement during transport A comparison of direct and oscillotonometric readings in critically ill patients , 1990, Anaesthesia.

[17]  S. Mieke,et al.  [Evaluation of the oscillometric blood pressure monitors: Dinamap 1846 and HP M-1008B]. , 1996, Der Anaesthesist.

[18]  E. Draper,et al.  APACHE II: A severity of disease classification system , 1985, Critical care medicine.

[19]  H. Lafeber,et al.  Accuracy of oscillometric blood pressure measurement in critically ill neonates with reference to the arterial pressure wave shape , 1996, Intensive Care Medicine.

[20]  D. Altman,et al.  Measuring agreement in method comparison studies , 1999, Statistical methods in medical research.

[21]  MD Patrick Whalen MSEE,et al.  A quantitative evaluation of the Hewlett-Packard 78354A noninvasive blood pressure meter , 2005, Journal of Clinical Monitoring.