MC Sensor—A Novel Method for Measurement of Muscle Tension

This paper presents a new muscle contraction (MC) sensor. This MC sensor is based on a novel principle whereby muscle tension is measured during muscle contractions. During the measurement, the sensor is fixed on the skin surface above the muscle, while the sensor tip applies pressure and causes an indentation of the skin and intermediate layer directly above the muscle and muscle itself. The force on the sensor tip is then measured. This force is roughly proportional to the tension of the muscle. The measurement is non-invasive and selective. Selectivity of MC measurement refers to the specific muscle or part of the muscle that is being measured and is limited by the size of the sensor tip. The sensor is relatively small and light so that the measurements can be performed while the measured subject performs different activities. Test measurements with this MC sensor on the biceps brachii muscle under isometric conditions (elbow angle 90°) showed a high individual linear correlation between the isometric force and MC signal amplitudes (0.97 ≤ r ≤ 1). The measurements also revealed a strong correlation between the MC and electromyogram (EMG) signals as well as good dynamic behaviour by the MC sensor. We believe that this MC sensor, when fully tested, will be a useful device for muscle mechanic diagnostics and that it will be complementary to existing methods.

[1]  A. Holbourn,et al.  The sounds from single motor units in a contracting muscle , 1948, The Journal of physiology.

[2]  B. Higginson,et al.  Methods of Running Gait Analysis , 2009, Current sports medicine reports.

[3]  R. Buschbacher Anatomical Guide for the Electromyographer: The Limbs and Trunk , 2007 .

[4]  D G Stuart,et al.  Neurobiology of muscle fatigue. , 1992, Journal of applied physiology.

[5]  Hazel M. Clarkson,et al.  Musculoskeletal Assessment: Joint Range of Motion and Manual Muscle Strength , 1989 .

[6]  J. van den Berg,et al.  EMG to force processing II: Estimation of parameters of the Hill muscle model for the human triceps surae by means of a calfergometer. , 1981, Journal of biomechanics.

[7]  R. Enoka Neuromechanics of Human Movement , 2001 .

[8]  V. Edgerton,et al.  Physiological cross‐sectional area of human leg muscles based on magnetic resonance imaging , 1992, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[9]  S. Gandevia Spinal and supraspinal factors in human muscle fatigue. , 2001, Physiological reviews.

[10]  V. Valencic,et al.  Evaluation of the ability to make non-invasive estimation of muscle contractile properties on the basis of the muscle belly response , 2006, Medical and Biological Engineering and Computing.

[11]  T. Fukunaga,et al.  In vivo moment arm determination using B-mode ultrasonography. , 2000, Journal of biomechanics.

[12]  R. Stein,et al.  The relation between the surface electromyogram and muscular force. , 1975, The Journal of physiology.

[13]  J. van den Berg,et al.  EMG to force processing IV: Eccentric-concentric contractions on a spring-flywheel set up. , 1981, Journal of biomechanics.

[14]  Gerrit Jan van Ingen Schenau,et al.  Does Elastic Energy Enhance Work and Efficiency in the Stretch-Shortening Cycle? , 1997 .

[15]  C. Orizio Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies. , 1993, Critical reviews in biomedical engineering.

[16]  Michelle Mielke,et al.  Mechanomyographic amplitude and frequency responses during dynamic muscle actions: a comprehensive review , 2005, Biomedical engineering online.

[17]  J. van den Berg,et al.  EMG to force processing I: An electrical analogue of the Hill muscle model. , 1981, Journal of biomechanics.

[18]  T J Housh,et al.  Mechanomyographic and electromyographic amplitude and frequency responses during fatiguing isokinetic muscle actions of the biceps brachii. , 2004, Electromyography and clinical neurophysiology.

[19]  J. van den Berg,et al.  EMG to force processing III: Estimation of model parameters for the human triceps surae muscle and assessment of the accuracy by means of a torque plate. , 1981, Journal of biomechanics.

[20]  M. Pierrynowski The Stretch-Shortening Cycle: A Model to Study Naturally Occurring Neuromuscular FatigueNicol C, Avela J, Komi PV (Univ of the Mediterranean, Marseilles, France; Univ of Jyväskylä, Finland) Sports Med36:977–999, 2006§ , 2007 .

[21]  D. T. Barry,et al.  Time-frequency analysis of skeletal muscle and cardiac vibrations , 1996, Proc. IEEE.

[22]  T. Fukunaga,et al.  In vivo estimation of contraction velocity of human vastus lateralis muscle during "isokinetic" action. , 2000, Journal of applied physiology.

[23]  B Bigland-Ritchie,et al.  EMG/FORCE RELATIONS AND FATIGUE OF HUMAN VOLUNTARY CONTRACTIONS , 1981, Exercise and sport sciences reviews.

[24]  Claudio Orizio,et al.  Soundmyogram and EMG cross-spectrum during exhausting isometric contractions in humans. , 1992, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[25]  Peripheral effects on the amplitude of monopolar and bipolar H-reflex potentials from the soleus muscle , 2004, Experimental Brain Research.

[26]  Richard L. Lieber,et al.  Skeletal Muscle Structure, Function, and Plasticity , 2009 .