Reconstruction of Corrupted and Lost Segments from Photoplethysmographic Data Using Recurrent Neural Network

Finger pulse signal, commonly known as Photoplethysmogram (PPG) is an important physiological signal used in intensive care unit (ICU) for heart rate and blood oxygen saturation measurement. In ICU monitoring for long-term analysis, there may be occasional clinical data corruption or loss due to either patient’s hand movement or sensor detachment from the measurement site. In this paper, we describe an approach to predict the lost and highly corrupted data segments from short history (immediate proceeding four beats) of the time series PPG data based on recurrent neural network (RNN). For identification of corrupted data segments, a support vector machine (SVM) in conjunction with Kernel radial basis function was used. The reconstruction of the lost segments and the corrupted segments from PPG data were carried out on a beat-by-beat basis, by using a joint principal component analysis (PCA) based feature extraction and RNN based data prediction model with recursive feeding of outputs to the PCA unit. Using finger PPG records of 40 volunteers, PPG beat classification sensitivity and specificity were found as of 98.1% and 91.78% respectively, with maximum absolute error (MAE) for single, consecutive five, and consecutive ten lost beats segments were 0.38%, 2.24% and 5.98% respectively.

[1]  R Petrolis,et al.  Principal component analysis based method for reconstruction of fragments of corrupted or lost signal in multilead data reflecting electrical heart activity and hemodynamics , 2010, 2010 Computing in Cardiology.

[2]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[3]  Max Q.-H. Meng,et al.  Robust peak detection of pulse waveform using height ratio , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  G Panda,et al.  A Novel Scheme of Data Compression and Reconstruction using Multilayer Artificial Neural Network , 1995 .

[5]  Andras Hartmann,et al.  Reconstruction of missing cardiovascular signals using adaptive filtering , 2010, 2010 Computing in Cardiology.

[6]  E. Hari Krishna,et al.  ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information , 2013, IEEE Transactions on Instrumentation and Measurement.

[7]  AM Sullivan,et al.  Reconstruction of missing physiological signals using artificial neural networks , 2010, 2010 Computing in Cardiology.

[8]  Yuan-Ting Zhang,et al.  Robust heart beat detection from photoplethysmography interlaced with motion artifacts based on Empirical Mode Decomposition , 2012, Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics.

[9]  Xiaopeng Zhao,et al.  Reconstruction of physiological signals using iterative retraining and accumulated averaging of neural network models , 2011, Physiological measurement.

[10]  Rajarshi Gupta,et al.  Improving Photoplethysmographic Measurements Under Motion Artifacts Using Artificial Neural Network for Personal Healthcare , 2018, IEEE Transactions on Instrumentation and Measurement.

[11]  Myoungho Lee,et al.  Adaptive threshold method for the peak detection of photoplethysmographic waveform , 2009, Comput. Biol. Medicine.

[12]  R. Ramon Fernandez de la Vara Prieto,et al.  Automated detection of the onset and systolic peak in the pulse wave using Hilbert transform , 2015, Biomed. Signal Process. Control..

[13]  W Karlen,et al.  Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation , 2012, Physiological measurement.

[14]  César Hervás-Martínez,et al.  Massive missing data reconstruction in ocean buoys with evolutionary product unit neural networks , 2016 .

[15]  Sumana Gupta,et al.  Region of Interest Reconstruction of Tomographic Images using Filter Banks , 2000 .

[16]  Q Li,et al.  Dynamic time warping and machine learning for signal quality assessment of pulsatile signals , 2012, Physiological measurement.

[17]  Jianfeng Weng,et al.  An Improved Pre-processing Approach for Photoplethysmographic Signal , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.