Chip integrated strategies for acoustic separation and manipulation of cells and particles.

Acoustic standing wave technology combined with microtechnology opens up new areas for the development of advanced particle and cell separating microfluidic systems. This tutorial review outlines the fundamental work performed on continuous flow acoustic standing wave separation of particles in macro scale systems. The transition to the microchip format is further surveyed, where both fabrication and design issues are discussed. The acoustic technology offers attractive features, such as reasonable throughput and ability to separate particles in a size domain of about tenths of micrometers to tens of micrometers. Examples of different particle separation modes enabled in microfluidic chips, utilizing standing wave technology, are described along a discussion of several potential applications in life science research and in the medical clinic. Chip integrated acoustic standing wave separation technology is still in its infancy and it can be anticipated that new laboratory standards very well may emerge from the current research.

[1]  Ewald Benes,et al.  Quantification of a novel h-shaped ultrasonic resonator for separation of biomaterials under terrestrial gravity and microgravity conditions. , 2003, Biotechnology and bioengineering.

[2]  Donald L Feke,et al.  Single fiber model of particle retention in an acoustically driven porous mesh. , 2003, Ultrasonics.

[3]  Thomas Laurell,et al.  Acoustic control of suspended particles in micro fluidic chips. , 2004, Lab on a chip.

[4]  D M Reboussin,et al.  Brain microemboli associated with cardiopulmonary bypass: a histologic and magnetic resonance imaging study. , 1995, The Annals of thoracic surgery.

[5]  Thomas Laurell,et al.  Ultrasonic agitation in microchannels , 2004, Analytical and bioanalytical chemistry.

[6]  Donald L. Feke,et al.  Acoustically driven collection of suspended particles within porous media , 1997 .

[7]  Thomas Laurell,et al.  Particle separation using ultrasound can radically reduce embolic load to brain after cardiac surgery. , 2004, The Annals of thoracic surgery.

[8]  Pekka Hänninen,et al.  Ultrasonic enrichment of microspheres for ultrasensitive biomedical analysis in confocal laser-scanning fluorescence detection , 2004 .

[9]  J. Giddings,et al.  Field-flow fractionation: analysis of macromolecular, colloidal, and particulate materials. , 1993, Science.

[10]  Thomas Laurell,et al.  Trapping of microparticles in the near field of an ultrasonic transducer. , 2005, Ultrasonics.

[11]  K. Yosioka,et al.  Acoustic radiation pressure on a compressible sphere , 1955 .

[12]  M Hill,et al.  A dual frequency, ultrasonic, microengineered particle manipulator. , 2004, Ultrasonics.

[13]  J. Scannell Thoracic surgery. , 1956, New England Journal of Medicine.

[14]  Martyn Hill,et al.  Modelling of layered resonators for ultrasonic separation. , 2002, Ultrasonics.

[15]  Bruce D. Bowen,et al.  Measurement of ultrasonic forces for particle–liquid separations , 1997 .

[16]  Shin-ichiro Umemura,et al.  Concentration and Fractionation of Small Particles in Liquid by Ultrasound , 1995 .

[17]  G. Gradl,et al.  A 3-D microelectrode system for handling and caging single cells and particles , 1999 .

[18]  Wesley L. Nyborg,et al.  Radiation Pressure on a Small Rigid Sphere , 1967 .

[19]  A. Kundt,et al.  Ueber longitudinale Schwingungen und Klangfiguren in cylindrischen Flüssigkeitssäulen , 1874 .

[20]  Donald L. Feke,et al.  Fractionation of suspensions using synchronized ultrasonic and flow fields , 1993 .

[21]  J M Piret,et al.  Batch and Semicontinuous Aggregation and Sedimentation of Hybridoma Cells by Acoustic Resonance Fields , 1995, Biotechnology progress.

[22]  W D White,et al.  Defining neuropsychological dysfunction after coronary artery bypass grafting. , 1996, The Annals of thoracic surgery.

[23]  Donald L. Feke,et al.  Methodology for fractionating suspended particles using ultrasonic standing wave and divided flow fields , 1995 .

[24]  S J Wyard,et al.  Blood cell banding in ultrasonic standing wave fields: a physical analysis. , 1978, Ultrasound in medicine & biology.

[25]  W. T. Coakley,et al.  Ultrasonic standing wave removal of microorganisms from suspension in small batch systems , 1996 .

[26]  A. Berg,et al.  Micro Total Analysis Systems , 1995 .

[27]  Thomas Laurell,et al.  Manipulation os suspended particles in a laminar flow , 2002 .

[28]  Donald L. Feke,et al.  Filtration of particulate suspensions in acoustically driven porous media , 1998 .

[29]  Donald L. Feke,et al.  Acoustically aided separation of oil droplets from aqueous emulsions , 2004 .

[30]  Jeremy J. Hawkes,et al.  Force field particle filter, combining ultrasound standing waves and laminar flow , 2001 .

[31]  Despina Bazou,et al.  Physical enviroment of 2-D animal cell aggregates formed in a short pathlength ultrasound standing wave trap. , 2005, Ultrasound in medicine & biology.

[32]  Lawrence A. Crum,et al.  Acoustic Force on a Liquid Droplet in an Acoustic Stationary Wave , 1971 .

[33]  Neil M. White,et al.  A silicon microfluidic ultrasonic separator , 2003 .

[34]  J.J. Hawkes,et al.  Resonant ultrasonic particle manipulators and their applications in sensor systems , 2004, Proceedings of IEEE Sensors, 2004..

[35]  James M. Piret,et al.  Acoustic Cell Filter for High Density Perfusion Culture of Hybridoma Cells , 1994, Bio/Technology.

[36]  H M Hertz,et al.  Ultrasonic-trap-enhanced selectivity in capillary electrophoresis. , 2003, Ultrasonics.

[37]  P J Keay,et al.  Plasma preparation from whole blood using ultrasound. , 2000, Ultrasound in medicine & biology.

[38]  Martyn Hill,et al.  The selection of layer thicknesses to control acoustic radiation force profiles in layered resonators. , 2003, The Journal of the Acoustical Society of America.

[39]  T. Laurell,et al.  Continuous separation of lipid particles from erythrocytes by means of laminar flow and acoustic standing wave forces. , 2005, Lab on a chip.

[40]  Thomas Laurell,et al.  Separation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels. , 2004, The Analyst.

[41]  J. C. Poggendorff Ueber das Verhalten des Quecksilbers bei seiner elektro-magnetischen Rotation , 2022 .

[42]  M. Elwenspoek,et al.  Silicon Micromachining , 1998 .

[43]  Manoj Kumar,et al.  Fractionation of cell mixtures using acoustic and laminar flow fields. , 2005, Biotechnology and bioengineering.

[44]  J. Hawkes,et al.  A continuous flow ultrasonic cell-filtering method , 1996 .

[45]  Ica Manas-Zloczower,et al.  Fractionation of mixed particulate solids according to compressibility using ultrasonic standing wave fields , 1995 .

[46]  Thomas Laurell,et al.  Carrier medium exchange through ultrasonic particle switching in microfluidic channels. , 2005, Analytical chemistry.

[47]  Thomas Laurell,et al.  Dynamic arraying of microbeads for bioassays in microfluidic channels , 2005 .

[48]  Robert W Barber,et al.  Continuous cell washing and mixing driven by an ultrasound standing wave within a microfluidic channel. , 2004, Lab on a chip.