In vivo thermal evaluation of a subretinal prosthesis using an integrated resistance temperature detector

Abstract. The temperature rise from the operation of implanted biomedical devices should be kept within a safe limit to prevent thermal damage or any undesirable thermal effects. To evaluate the temperature rise from the operation of an implanted high-density microelectrodes array (MEA) on a flex in the subretinal space, we directly integrated resistance temperature detectors into this retinal MEA device in the same micro fabrication. We surgically implanted this MEA device in the subretinal space of a rabbit model and measured the temperature rise in vivo. The measured temperature rise is consistent with the calculated values from the finite element method. Experiment showed the temperature versus power dissipation of the MEA device had a slope of 0.84°C/(mW·mm−2). To ensure the temperature rise is within 1.0°C, the maximum power dissipation on the retinal implant should be kept within 1.2  mW·mm−2.

[1]  David B. Grayden,et al.  Heating of the Eye by a Retinal Prosthesis: Modeling, Cadaver and In Vivo Study , 2012, IEEE Transactions on Biomedical Engineering.

[2]  Kea-Tiong Tang,et al.  A Center-Surround-Selectable, High-Acuity, Large-Field-of-View, Flexible Retinal Prosthesis , 2013 .

[3]  G. Lazzi,et al.  Thermal effects of bioimplants , 2005, IEEE Engineering in Medicine and Biology Magazine.

[4]  G. Bozkir,et al.  Measurements of axial length and radius of corneal curvature in the rabbit eye. , 1997, Acta medica Okayama.

[5]  Eberhart Zrenner,et al.  Investigation of thermal effects of infrared lasers on the rabbit retina: a study in the course of development of an active subretinal prosthesis , 2007, Graefe's Archive for Clinical and Experimental Ophthalmology.

[6]  Y. Ibata,et al.  Effects of heating on electrical activities of guinea pig olfactory cortical slices , 2004, Pflügers Archiv.

[7]  Mitsumasa Koyanagi,et al.  Pillar-shaped stimulus electrode array for high-efficiency stimulation of fully implantable epiretinal prosthesis , 2012 .

[8]  Thomas D'Arcy McGee,et al.  Principles and Methods of Temperature Measurement , 1988 .

[9]  James D. Weiland,et al.  Thermal elevation in the human eye and head due to the operation of a retinal prosthesis , 2004, IEEE Transactions on Biomedical Engineering.

[10]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[11]  Daniel Palanker High Resolution Optoelectronic Retinal Prosthesis , 2007 .

[12]  Toward a high visual-acuity retinal prosthesis , 2013, 2013 Transducers & Eurosensors XXVII: The 17th International Conference on Solid-State Sensors, Actuators and Microsystems (TRANSDUCERS & EUROSENSORS XXVII).

[13]  Otto J. Prohaska,et al.  Stimulus-activated changes in brain tissue temperature in the anesthetized rat , 1989, Metabolic Brain Disease.

[14]  H. F. Bowman,et al.  Theory, measurement, and application of thermal properties of biomaterials. , 1975, Annual review of biophysics and bioengineering.

[15]  T. Seese,et al.  Characterization of tissue morphology, angiogenesis, and temperature in the adaptive response of muscle tissue to chronic heating. , 1998, Laboratory investigation; a journal of technical methods and pathology.

[16]  Wolfgang Legner,et al.  Microthruster with integrated platinum thin film resistance temperature detector (RTD), heater, and thermal insulation , 2011, Microtechnologies.

[17]  Keiichiro Kagawa,et al.  Proposal of Application of Pulsed Vision Chip for Retinal Prosthesis. , 2002 .