Energy-Efficient High-Voltage Pulsers for Ultrasound Transducers

This brief reviews high-voltage pulsers for ultrasound imaging systems with a focus on energy efficiency. Most ultrasound imaging systems have been developed with the aim of achieving a high signal-to-noise ratio for good image quality. As miniaturization and portability of the systems are pursued recently, high energy efficiency is of great need. In the ultrasonic imaging systems, the most power-hungry block is typically the pulser that drives the ultrasound transducer at a high voltage. To better understand the pulser’s operation and power consumption, an equivalent circuit model of the transducer is introduced. Based on the model, we investigate the fundamentals of pulser driving methods and review the conventional class-D pulser as well as state-of-the-art pulsers with dynamic power loss reduction techniques. Their operation principles, strengths, and limitations are analyzed and discussed in depth.

[1]  Hao Yu,et al.  High-voltage pulser for ultrasound medical imaging applications , 2011, 2011 International Symposium on Integrated Circuits.

[2]  Sandy Cochran,et al.  Ultrasound capsule endoscopy: sounding out the future. , 2017, Annals of translational medicine.

[3]  J. D. Larson,et al.  Modified Butterworth-Van Dyke circuit for FBAR resonators and automated measurement system , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[4]  Yexian Qin,et al.  Optimizing frequency and pulse shape for ultrasound current source density imaging , 2012, 2011 IEEE International Ultrasonics Symposium.

[5]  Vivek T. Rathod,et al.  A Review of Electric Impedance Matching Techniques for Piezoelectric Sensors, Actuators and Transducers , 2019, Electronics.

[6]  Jerald Yoo,et al.  A 2.34μJ/scan acoustic power scalable charge-redistribution pMUT interface system with on-chip aberration compensation for portable ultrasonic applications , 2016, 2016 IEEE Asian Solid-State Circuits Conference (A-SSCC).

[7]  Kyusun Choi,et al.  High frequency piezoelectric MEMS ultrasound transducers , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Maysam Ghovanloo,et al.  Supply-Doubled Pulse-Shaping High Voltage Pulser for CMUT Arrays , 2018, IEEE Transactions on Circuits and Systems II: Express Briefs.

[9]  Hae-Seung Lee,et al.  Ultrasonic Imaging Transceiver Design for CMUT: A Three-Level 30-Vpp Pulse-Shaping Pulser With Improved Efficiency and a Noise-Optimized Receiver , 2013, IEEE Journal of Solid-State Circuits.

[10]  Mohamad Sawan,et al.  Fully Integrated High-Voltage Front-End Interface for Ultrasonic Sensing Applications , 2007, IEEE Transactions on Circuits and Systems I: Regular Papers.

[11]  Kyusun Choi,et al.  CMOS Ultrasound Transceiver Chip for High-Resolution Ultrasonic Imaging Systems , 2009, IEEE Transactions on Biomedical Circuits and Systems.

[13]  Jia Hao Cheong,et al.  A CMOS High-Voltage Transmitter IC for Ultrasound Medical Imaging Applications , 2013, IEEE Transactions on Circuits and Systems II: Express Briefs.

[14]  Lei Zhang,et al.  The Effect of Electrical Impedance Matching on the Electromechanical Characteristics of Sandwiched Piezoelectric Ultrasonic Transducers , 2017, Sensors.

[15]  Jordi Salazar,et al.  High-power high-resolution pulser for air-coupled ultrasonic NDE applications , 2003, IEEE Trans. Instrum. Meas..

[16]  Linas Svilainis,et al.  Efficient high voltage pulser for piezoelectric air coupled transducer. , 2013, Ultrasonics.

[17]  Qifa Zhou,et al.  Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy , 2017, IEEE Transactions on Medical Imaging.

[18]  Chao Chen,et al.  A 0.91mW/element pitch-matched front-end ASIC with integrated subarray beamforming ADC for miniature 3D ultrasound probes , 2018, 2018 IEEE International Solid - State Circuits Conference - (ISSCC).

[19]  Yikai Wang,et al.  Low-Noise CMOS TGC Amplifier With Adaptive Gain Control for Ultrasound Imaging Receivers , 2011, IEEE Transactions on Circuits and Systems II: Express Briefs.

[20]  Bernhard E. Boser,et al.  11.8 Integrated ultrasonic system for measuring body-fat composition , 2015, 2015 IEEE International Solid-State Circuits Conference - (ISSCC) Digest of Technical Papers.

[21]  Morten Fischer Rasmussen,et al.  Capsule ultrasound device: Characterization and testing results , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[22]  Hoi-Jun Yoo,et al.  11.1 A 5.37mW/Channel Pitch-Matched Ultrasound ASIC with Dynamic-Bit-Shared SAR ADC and 13.2V Charge-Recycling TX in Standard CMOS for Intracardiac Echocardiography , 2019, 2019 IEEE International Solid- State Circuits Conference - (ISSCC).

[23]  Haiying Huang,et al.  Broadband electrical impedance matching for piezoelectric ultrasound transducers , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Nico de Jong,et al.  A Front-End ASIC With High-Voltage Transmit Switching and Receive Digitization for 3-D Forward-Looking Intravascular Ultrasound Imaging , 2018, IEEE Journal of Solid-State Circuits.

[25]  Edgar Sanchez-Sinencio,et al.  An Automatic Resonance Tracking Scheme With Maximum Power Transfer for Piezoelectric Transducers , 2015, IEEE Transactions on Industrial Electronics.

[26]  C. K. Abbey,et al.  Effects of frequency and bandwidth on diagnostic information transfer in ultrasonic B-Mode imaging , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.