A CMOS Gas Sensor Array Platform With Fourier Transform Based Impedance Spectroscopy

A CMOS gas sensor array platform with digital read-out containing 27 sensor pixels and a reference pixel is presented. A signal conditioning circuit at each pixel includes digitally programmable gain stages for sensor signal amplification followed by a second order continuous time delta sigma modulator for digitization. Each sensor pixel can be functionalized with a distinct sensing material that facilitates transduction based on impedance change. Impedance spectrum (up to 10 KHz) of the sensor is obtained off-chip by computing the fast Fourier transform of sensor and reference pixel outputs. The reference pixel also compensates for the phase shift introduced by the signal processing circuits. The chip also contains a temperature sensor with digital readout for ambient temperature measurement. A sensor pixel is functionalized with polycarbazole conducting polymer for sensing volatile organic gases and measurement results are presented. The chip is fabricated in a 0.35 μm CMOS technology and requires a single step post processing for functionalization. It consumes 57 mW from a 3.3 V supply.

[1]  Ricardo Gutierrez-Osuna,et al.  Pattern analysis for machine olfaction: a review , 2002 .

[2]  Richard B. Kaner,et al.  Polyaniline Nanofiber Gas Sensors: Examination of Response Mechanisms , 2004 .

[3]  A. L. Kukla,et al.  Application of sensor arrays based on thin films of conducting polymers for chemical recognition of volatile organic solvents , 2009 .

[4]  Rik W. De Doncker,et al.  Impedance-based non-linear dynamic battery modeling for automotive applications , 2003 .

[5]  J. Gardner,et al.  Polymeric resistive bridge gas sensor array driven by a standard cell CMOS current drive chip , 1999 .

[6]  Nataliya V. Roznyatovskaya,et al.  Conducting polymers in chemical sensors and arrays. , 2008, Analytica chimica acta.

[7]  Hua Bai,et al.  Gas Sensors Based on Conducting Polymers , 2007, Sensors (Basel, Switzerland).

[8]  Amine Bermak,et al.  A monolithic integrated 4 × 4 tin oxide gas sensor array with on-chip multiplexing and differential readout circuits , 2007 .

[9]  Oliver Tomic,et al.  Independent component analysis applied on gas sensor array measurement data , 2003 .

[10]  Chao Yang,et al.  Analysis of On-Chip Impedance Spectroscopy Methodologies for Sensor Arrays , 2006 .

[11]  Amine Bermak,et al.  A CMOS Single-Chip Gas Recognition Circuit for Metal Oxide Gas Sensor Arrays , 2011, IEEE Transactions on Circuits and Systems I: Regular Papers.

[12]  N. T. Kemp,et al.  Temperature-dependent conductivity of conducting polymers exposed to gases , 1999 .

[13]  Kea-Tiong Tang,et al.  A polymer-based gas sensor array and its adaptive interface circuit , 2010, Proceedings of 2010 International Symposium on VLSI Design, Automation and Test.

[14]  Alister Hamilton,et al.  Analog VLSI Circuit Implementation of an Adaptive Neuromorphic Olfaction Chip , 2007, IEEE Transactions on Circuits and Systems I: Regular Papers.

[15]  Jack W. Judy,et al.  Micromachined polymer-based chemical gas sensor array , 2001 .

[16]  Su-Moon Park,et al.  Electrochemical impedance spectroscopy. , 2010, Annual review of analytical chemistry.

[17]  G. Temes Delta-sigma data converters , 1994 .

[18]  Shanthi Pavan,et al.  Fundamental Limitations of Continuous-Time Delta–Sigma Modulators Due to Clock Jitter , 2007, IEEE Transactions on Circuits and Systems I: Regular Papers.

[19]  Arjang Hassibi,et al.  A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[20]  N.S. Lewis,et al.  A VLSI compatible conducting polymer composite based "electronic nose" chip , 2002, Digest. International Electron Devices Meeting,.

[21]  E. Barsoukov,et al.  Impedance spectroscopy : theory, experiment, and applications , 2005 .

[22]  C. Hagleitner,et al.  CMOS Monolithic Metal–Oxide Gas Sensor Microsystems , 2006, IEEE Sensors Journal.

[23]  Shanthi Pavan,et al.  A Power Optimized Continuous-Time $\Delta \Sigma $ ADC for Audio Applications , 2008, IEEE Journal of Solid-State Circuits.

[24]  Dinesh K. Aswal,et al.  In situ spectroscopic studies to investigate uncharacteristic NH3 sensing behavior of polycarbazole Langmuir–Blodgett films , 2010 .

[25]  Florin Udrea,et al.  CMOS Interfacing for Integrated Gas Sensors: A Review , 2010, IEEE Sensors Journal.

[26]  Andrew J. Mason,et al.  A fully integrated multi-channel impedance extraction circuit for biosensor arrays , 2010, Proceedings of 2010 IEEE International Symposium on Circuits and Systems.

[27]  Bo Li,et al.  Volatile organic compound detection using nanostructured copolymers. , 2006, Nano letters.

[28]  Shanthi Pavan Systematic Design Centering of Continuous Time Oversampling Converters , 2010, IEEE Transactions on Circuits and Systems II: Express Briefs.