Optical method for measurement of respiration rate

Standard instrumentation for the assessment of the respiration rate is largely used in medicine. Spirometers, textile-based capacitive sensors or photopletismography are all contact devices used for such aim; the main drawback in their use is the necessity to have a direct contact between the instrument and the patient, which in some cases can limit the use of such devices. In this paper, we present an optical, fully no-contact measurement method for monitoring of the respiration rate, based on the assessment of chest wall movements (velocity and displacement) by a laser Doppler vibrometer (LDVi). The proposed method is operated at a distance of 1.5 m, on different point of the patient thoracic and abdominal area. The measurement procedure was already demonstrated to precisely perform for what concern the monitoring of the cardiac activity. In this paper, we have monitored 33 patients with a reference instrument (spirometer) and with the proposed non-contact method. Statistical analysis (Bland-Altman) of the respiration rate measured with both instruments is reported. We also report a study on the optimal position on the thoracic area based on quality of the signal measured on the same population of subject. Results demonstrate the possibility to continuously monitor the respiration rate with a mean difference respect to the spirometer data of 13 m ( relative error: 0.35%).

[1]  Douglas G. Altman,et al.  Measurement in Medicine: The Analysis of Method Comparison Studies , 1983 .

[2]  U. Morbiducci,et al.  Non-contact cardiac monitoring from carotid artery using optical vibrocardiography. , 2008, Medical engineering & physics.

[3]  U. Morbiducci,et al.  From cardiac to respiratory rate, from cardiac sounds to pulse velocity: a noncontact unified approach for the monitoring of vital signs by means of optical vibrocardiography , 2008, International Conference on Vibration Measurements by Laser Techniques: Advances and Applications.

[4]  T. Meydan,et al.  Method for continuous nondisturbing monitoring of blood pressure by magnetoelastic skin curvature sensor and ECG , 2006, IEEE Sensors Journal.

[5]  Enrico Primo Tomasini,et al.  Carotid artery pulse wave measured by a laser vibrometer , 1998, Other Conferences.

[6]  Umberto Morbiducci,et al.  A laser Doppler approach to cardiac motion monitoring: effects of surface and measurement position , 2006, International Conference on Vibration Measurements by Laser Techniques: Advances and Applications.

[7]  Joseph D. Bronzino,et al.  The Biomedical Engineering Handbook , 1995 .

[8]  Enrico Primo Tomasini,et al.  Laser Doppler Vibrometry: Development of advanced solutions answering to technology's needs , 2006 .

[9]  M. Grigioni,et al.  Optical Vibrocardiography: A Novel Tool for the Optical Monitoring of Cardiac Activity , 2006, Annals of Biomedical Engineering.

[10]  Chen-Chia Wang,et al.  Human Life Signs Detection Using High-Sensitivity Pulsed Laser Vibrometer , 2007, IEEE Sensors Journal.

[11]  E. P. Tomasini,et al.  A preliminary study for the evaluation of large artery stiffness: a non contact approach , 2008 .

[12]  C.R. Merritt,et al.  Textile-Based Capacitive Sensors for Respiration Monitoring , 2009, IEEE Sensors Journal.

[13]  L. Scalise,et al.  Identification of cardiac events by Optical Vibrocardiograpy: comparison with Phonocardiography , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[14]  A. Johansson,et al.  Monitoring of Heart and Respiratory Rates in Newborn Infants Using a New Photoplethysmographic Technique , 1999, Journal of Clinical Monitoring and Computing.