A recursive time-domain formulation for electromagnetic transient analysis in power networks has recently been derived drawing on a particular transformation sequence in which the z-transform has a central part. Following its original development primarily in the context of overhead lines, the present paper investigates the possible rOle of the formulation in transient propagation in crossbonded underground cable systems. In those terms, the earlier z-plane analysis scheme extends easily to the conductor and sheath configuration of a cable section between points of successive sheath discontinuities. It is then shown in the paper, in detailed working, how the boundary conditions of sheath transpositions, sheath earthing, and surge-arrester connections may be introduced into analysis. From the outcome of this working, an overall solution procedure is formulated for a cable system of any arbitrary number of sections in terms of the individual section equations rearranged to comply with the boundary conditions which they are required to fulfil. A Newton-Raphson algorithm is used to solve the nonlinear equations of surge arresters in conjunction with those of the cable sheaths to which they are connected. Close comparisons with solutions from an established Fourier transform method confirm, as in the overhead line case, the high underlying accuracy of z-transform analysis. Computing time requirements have a dependence on the number of sections into which the complete cable system is subdivided: for three sections, z-transform computing times are about 1% of those in Fourier transform analysis
[1]
D. J. Wilcox,et al.
Implementation of nonhomogeneous theory in the transient analysis of crossbonded cable systems
,
1978
.
[2]
W. D. Humpage,et al.
Z-transform electromagnetic transient analysis in power systems
,
1980
.
[3]
R.Ch.G. Bergmann,et al.
Calculation of electrical transients in power systems: untransposed transmission line with frequency-dependent parameters
,
1979
.
[4]
L. M. Wedepohl,et al.
Determination of the open-circuit sheath voltages of cable systems
,
1968
.
[5]
C.S. Indulkar,et al.
Switching Overvoltages in Long Crossbonded Cable Systems Using the Fourier Transform
,
1979,
IEEE Transactions on Power Apparatus and Systems.
[6]
L. M. Wedepohl,et al.
Estimation of transient sheath overvoltages in power-cable transmission systems
,
1973
.
[7]
W. Derek Humpage,et al.
Impulse sampling sequences in time-convolution electromagnetic transient analysis in power systems
,
1981
.
[8]
L. M. Wedepohl,et al.
Wave propagation in nonhomogeneous systems. Properties of the chain matrix
,
1974
.
[9]
L. M. Wedepohl,et al.
Transient analysis of underground power-transmission systems. System-model and wave-propagation characteristics
,
1973
.
[10]
Colin Adamson,et al.
Comparative steady-state performance of crossbonded cable systems
,
1968
.