Coherent backscattering in biological media: measurement and estimation of optical properties.

We measured the coherent backscattering of light from milk solutions and biological tissues by using a He-Ne laser (633 nm) and a CCD array as a detector. A coherent peak from the milk solutions could bemeasured with a single exposure. However, ensemble averaging was required for coherent peaks to be produced from solid media such as tissue samples. By fitting experimental data to an existing model numerically, effective scattering and absorption coefficients were estimated. They were compared with those computed from integrating sphere measurements. Effective scattering coefficients computed by the two different methods were in good agreement for high-scattering media. However, higher absorption was estimated by the coherent peak method.

[1]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[2]  P. Anderson Absence of Diffusion in Certain Random Lattices , 1958 .

[3]  D. Marquardt An Algorithm for Least-Squares Estimation of Nonlinear Parameters , 1963 .

[4]  T. Gehrels,et al.  Wavelength dependence of polarization. iii - the lunar surface. , 1964 .

[5]  Yu. A. Kravtsov,et al.  METHODOLOGICAL NOTES: Effects of double passage of waves in randomly inhomogeneous media , 1982 .

[6]  A. Ishimaru,et al.  Retroreflectance from a dense distribution of spherical particles , 1984 .

[7]  Wolf,et al.  Weak localization and coherent backscattering of photons in disordered media. , 1985, Physical review letters.

[8]  Wolf,et al.  Coherent backscattering of light by disordered media: Analysis of the peak line shape. , 1986, Physical review letters.

[9]  Etemad,et al.  Weak localization of photons: Universal fluctuations and ensemble averaging. , 1986, Physical review letters.

[10]  M S Patterson,et al.  INDIRECT VERSUS DIRECT TECHNIQUES FOR THE MEASUREMENT OF THE OPTICAL PROPERTIES OF TISSUES , 1987, Photochemistry and photobiology.

[11]  Lagendijk,et al.  Observation of weak localization of light in a finite slab: Anisotropy effects and light path classification. , 1987, Physical review letters.

[12]  G. Maret,et al.  Theoretical study of the coherent backscattering of light by disordered media , 1988 .

[13]  A J Welch,et al.  Accuracies of the diffusion approximation and its similarity relations for laser irradiated biological media. , 1989, Applied optics.

[14]  A J Welch,et al.  Light and temperature distribution in laser irradiated tissue: the influence of anisotropic scattering and refractive index. , 1989, Applied optics.

[15]  S. Jacques,et al.  Light distributions in artery tissue: Monte Carlo simulations for finite‐diameter laser beams , 1989, Lasers in surgery and medicine.

[16]  G. C. Tang,et al.  Coherent backscattering of light from biological tissues. , 1990, Applied optics.

[17]  S. John,et al.  Localization of Light , 1991 .