Comparative evaluation of the dustiness of industrial minerals according to European standard EN 15051, 2006.

A range of industrial minerals was tested using the rotating drum and the continuous drop methods, the two methods proposed by the published European standard EN 15051 [CEN. (2006) EN 15051 Workplace atmospheres-measurement of the dustiness of bulk materials-requirements and test methods. Brussels, Belgium: European Committee for Standardization], to evaluate and compare their dustiness. The assessment of bulk materials dustiness can help to develop less dusty products and to reduce dust exposure to the workers by improving the processing of minerals. The European standard EN 15051 (CEN, 2006) proposes a classification system that was developed with the intention to assist in the labelling of products in the future. This paper presents a comparison of both test methods in classifying industrial minerals. The correlation between the dustiness measured by the two methods for the inhalable and respirable fractions is given. The results show there is no unambiguous dependence of the dustiness on the grain size of an industrial mineral. Although dustiness can significantly be affected by product moisture, the influence of this parameter is not studied in detail as the industrial minerals were tested in the conditions they are sold, as the standard requires. Especially, the classification of substances with respect to different classes of dustiness was found to be problematic, as the two methods are by no means yielding identical classification groups for all the substances. In any use of the standard (EN 15051; CEN, 2006) for labelling purposes, a revision of the present classification system provided in the standard is required for industrial minerals.