Non-aerosol detection of explosives with a continuous flow immunosensor

Contamination of groundwater, soil, and the marine environment by explosives is a global issue. Identification, characterization and remediation are all required for a site recognized as contaminated with 2,4,6-trinitrotoluene (TNT) or hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX). For each step, a method to accurately measure the contaminant level is needed. This paper reviews some of the current methods with emphasis on a single biosensor developed in our laboratory. Current regulatory methods require samples to be sent off-site to a certified laboratory resulting in time delays up to a month. A continuous flow biosensor for detection of explosives has been developed and tested for the rapid field screening of environmental samples. The detection system is based on a displacement immunoassay in which monoclonal antibodies to (TNT) and RDX are immobilized on solid substrates, allowed to bind fluorescently labeled antigens, and then exposed to explosives in aqueous samples. Explosive compounds present in the sample displace proportional amounts of the fluorescent label, which can then be measured to determine the original TNT or RDX concentration. The system can accurately detect ppb to ppt levels of explosives in groundwater or seawater samples and in extracts of contaminated soil. The biosensor has applications in environmental monitoring at remediation sites or in the location of underwater unexploded ordnance.

[1]  Bailey,et al.  Separation and detection of explosives on a microchip using micellar electrokinetic chromatography and indirect laser-induced fluorescence , 2000, Analytical chemistry.

[2]  Ann B. Strong,et al.  Comparison of solid phase extraction with salting-out solvent extraction for preconcentration of nitroaromatic and nitramine explosives from water , 1994 .

[3]  Anne W. Kusterbeck,et al.  Field demonstration of a portable flow immunosensor , 1998 .

[4]  Frances S. Ligler,et al.  On-site detection of TNT with a portable fiber optic biosensor , 1997 .

[5]  Lisa C. Shriver-Lake,et al.  On-site detection of explosives in groundwater with a fiber optic biosensor , 2000 .

[6]  Anne W. Kusterbeck,et al.  Enhanced biosensor performance for on‐site field analysis of explosives in water using solid‐phase extraction membranes , 2001 .

[7]  A FIBER OPTIC BIOSENSOR FOR MULTIANALYTE DETECTION : IMPORTANCE OF PREVENTING FLUOROPHORE AGGREGATION , 1998 .

[8]  Frances S. Ligler,et al.  Capillary-Based Displacement Flow Immunosensor , 1997 .

[9]  A. Kusterbeck,et al.  Environmental immunoassay for the explosive RDX using a fluorescent dye-labeled antigen and the continuous-flow immunosensor , 1997 .

[10]  E. Sahlin,et al.  Chromatographic detection of nitroaromatic and nitramine compounds by electrochemical reduction combined with photoluminescence following electron transfer. , 2000, Analytical chemistry.

[11]  G. Anderson,et al.  Detection of 2,4,6-trinitrotoluene in seawater using a reversed-displacement immunosensor. , 2002, Analytical biochemistry.

[12]  Joseph H. Aldstadt,et al.  Selective determination of TNT in soil extracts by sequential injection spectrophotometry , 1999 .

[13]  A. Hilmi,et al.  Development of Electrokinetic Capillary Electrophoresis Equipped with Amperometric Detection for Analysis of Explosive Compounds , 1999 .

[14]  U. Narang,et al.  Multianalyte detection using a capillary-based flow immunosensor. , 1998, Analytical biochemistry.

[15]  Anne W. Kusterbeck,et al.  On-Site Immunoanalysis of Nitrate and Nitroaromatic Compounds in Groundwater , 2000 .

[16]  Reinhard Bredehorst,et al.  Continuous-flow immunosensor for detection of explosives , 1993 .

[17]  John H. T. Luong,et al.  Micromachined Electrophoresis Chips with Electrochemical Detectors for Analysis of Explosive Compounds in Soil and Groundwater , 2000 .

[18]  Frances S. Ligler,et al.  Multi-analyte explosive detection using a fiber optic biosensor , 1999 .

[19]  A W Kusterbeck,et al.  Explosives detection in soil using a field-portable continuous flow immunosensor. , 2001, Journal of hazardous materials.

[20]  Upvan Narang,et al.  A displacement flow immunosensor for explosive detection using microcapillaries , 1997 .

[21]  A. Kusterbeck,et al.  Application of a Portable Immunosensor To Detect the Explosives TNT and RDX in Groundwater Samples , 1997 .

[22]  A. Kusterbeck,et al.  Trace level detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) by microimmunosensor. , 1999, Biosensors & bioelectronics.

[23]  Qin Lu,et al.  Sensitive capillary electrophoresis microchip determination of trinitroaromatic explosives in nonaqueous electrolyte following solid phase extraction , 2002 .

[24]  Frances S. Ligler,et al.  A membrane-based displacement flow immunoassay , 1998 .