Dielectric measurements using a rational function model

A recently proposed rational function model for the aperture admittance of 50 ohm Teflon filled coaxial lines in contact with a homogeneous dielectric is experimentally validated. A calibration technique of the automatic network analyzer utilizing standard terminations and time domain gating is used. Uncertainties in the dielectric properties of reference liquids do not enter the calibration procedure. Experimental results for water and methanol are compared with estimated values. A model expression for the sensitivity of the probe is validated. The sensitivities of two coaxial line probes for the measurements made are determined. Results obtained using the new model are compared with those of other workers. >

[1]  M. Stuchly,et al.  Coaxial Line Reflection Methods for Measuring Dielectric Properties of Biological Substances at Radio and Microwave Frequencies-A Review , 1980, IEEE Transactions on Instrumentation and Measurement.

[2]  S. S. Stuchly,et al.  Permittivity measurements using open-ended sensors and reference liquid calibration-an uncertainty analysis , 1992 .

[3]  Liu Liping,et al.  Measurement of Dielectic Properties of Biological Substances Using Improved Open-Ended Coaxial Line Resonator Method , 1987, 1987 IEEE MTT-S International Microwave Symposium Digest.

[4]  E. Tanabe,et al.  A nondestructive method for measuring the complex permittivity of dielectric materials at microwave frequencies using an open transmission line resonator , 1976, IEEE Transactions on Instrumentation and Measurement.

[5]  E. C. Burdette,et al.  In Vivo Probe Measurement Technique for Determining Dielectric Properties at VHF through Microwave Frequencies , 1980 .

[6]  S. S. Stuchly,et al.  A new aperture admittance model for open-ended waveguides , 1992 .

[7]  D. K. Misra,et al.  A Quasi-Static Analysis of Open-Ended Coaxial Lines (Short Paper) , 1987 .

[8]  Stanislaw S. Stuchly,et al.  An Equivalent Circuit of an Open-Ended Coaxial Line , 1983, IEEE Transactions on Instrumentation and Measurement.

[9]  H. E. Bussey,et al.  Measurement of RF properties of materials a survey , 1967 .

[10]  S. Stuchly,et al.  Dielectric Behavior of Selected Animal Tissues in Vitro at Frequencies from 2 to 4 GHz , 1981, IEEE Transactions on Biomedical Engineering.

[11]  Kenneth R. Foster,et al.  Noninvasive electrical characterization of materials at microwave frequencies using an open-ended coaxial line: test of an improved calibration technique , 1990 .

[12]  Maria A. Stuchly,et al.  Measurement of Radio Frequency Permittivity of Biological Tissues with an Open-Ended Coaxial Line: Part I , 1982 .