Poly (3, 4-ethylenedioxythiophene)-ionic liquid coating improves neural recording and stimulation functionality of MEAs.

In vivo multi-electrode arrays (MEAs) can sense electrical signals from a small set of neurons or modulate neural activity through micro-stimulation. Electrode's geometric surface area (GSA) and impedance are important for both unit recording and neural stimulation. Smaller GSA is preferred due to enhanced selectivity of neural signal, but it tends to increase electrode impedance. Higher impedance leads to increased electrical noise and signal loss in single unit neural recording. It also yields a smaller charge injection window for safe neural stimulation. To address these issues, poly (3, 4-ethylenedioxythiophene) - ionic liquid (PEDOT-IL) conducting polymers were electrochemically polymerized on the surface of the microelectrodes. The PEDOT-IL coating reduced the electrode impedance modulus by over 35 times at 1 kHz. It also exhibited compelling nanostructure in surface morphology and significant impedance reduction in other physiologically relevant range (100Hz-1000Hz). PEDOT-IL coated electrodes exhibited a Charge Storage Capacity (CSC) that was about 20 times larger than that of bare electrodes. The neural recording performance of PEDOT-IL coated electrodes was also compared with uncoated electrodes and PEDOT-poly (styrenesulfonate) (PSS) coated electrodes in rat barrel cortex (SI). Spontaneous neural activity and sensory evoked neural response were utilized for characterizing the electrode performance. The PEDOT-IL electrodes exhibited a higher unit yield and signal-to-noise ratio (SNR) in vivo. The local field potential recording was benefited from the low impedance PEDOT-IL coating in noise and artifact reduction as well. Moreover, cell culture on PEDOT-IL coating demonstrated that the material is safe for neural tissue and reduces astrocyte fouling. Taken together, PEDOT-IL coating has the potential to benefit neural recording and stimulation electrodes, especially when integrated with novel small GSA electrode arrays designed for high recording density, minimal insertion damage and alleviated tissue reaction.

[1]  R. Giernoth Task-specific ionic liquids. , 2010, Angewandte Chemie.

[2]  Jonathan Rivnay,et al.  Ionic Liquid Gel‐Assisted Electrodes for Long‐Term Cutaneous Recordings , 2014, Advanced healthcare materials.

[3]  S. Cogan Neural stimulation and recording electrodes. , 2008, Annual review of biomedical engineering.

[4]  Thomas Schanze,et al.  Visual resolution with retinal implants estimated from recordings in cat visual cortex , 2006, Vision Research.

[5]  David J. Anderson,et al.  Electrochemical deposition and characterization of conducting polymer polypyrrole/PSS on multichannel neural probes , 2001 .

[6]  G. Wallace,et al.  Use of Ionic Liquids for π-Conjugated Polymer Electrochemical Devices , 2002, Science.

[7]  G. Pfurtscheller,et al.  Brain-Computer Interfaces for Communication and Control. , 2011, Communications of the ACM.

[8]  H. Lüders,et al.  Deep Brain Stimulation in Epilepsy , 2001, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[9]  Bruno Scrosati,et al.  Ionic-liquid materials for the electrochemical challenges of the future. , 2009, Nature materials.

[10]  Xuan Cheng,et al.  Poly(3,4-ethylenedioxythiophene)/multiwall carbon nanotube composite coatings for improving the stability of microelectrodes in neural prostheses applications. , 2013, Acta biomaterialia.

[11]  Andrew B. Schwartz,et al.  Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics , 2006, Neuron.

[12]  A. Ivaska,et al.  Electrochemical synthesis and in situ spectroelectrochemical characterization of poly(3,4-ethylenedioxythiophene) (PEDOT) in room temperature ionic liquids , 2004 .

[13]  X Tracy Cui,et al.  Effects of caspase-1 knockout on chronic neural recording quality and longevity: insight into cellular and molecular mechanisms of the reactive tissue response. , 2014, Biomaterials.

[14]  J. Hetke,et al.  Surface modification of neural recording electrodes with conducting polymer/biomolecule blends. , 2001, Journal of biomedical materials research.

[15]  Xiliang Luo,et al.  Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation. , 2011, Biomaterials.

[16]  James Ross Macdonald,et al.  IMPEDANCE SPECTROSCOPY: OLD PROBLEMS AND NEW DEVELOPMENTS , 1990 .

[17]  Ari Ivaska,et al.  Electrochemical biosensors based on polyaniline , 2006 .

[18]  Christopher K. Ober,et al.  Advances in polymers for anti-biofouling surfaces , 2008 .

[19]  Jin-Kyu Lee,et al.  Nanostructuring of a polymeric substrate with well-defined nanometer-scale topography and tailored surface wettability. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[20]  Justin C. Sanchez,et al.  Comprehensive characterization and failure modes of tungsten microwire arrays in chronic neural implants , 2012, Journal of neural engineering.

[21]  David C. Martin,et al.  In vivo studies of polypyrrole/peptide coated neural probes. , 2003, Biomaterials.

[22]  B Jastorff,et al.  Design of sustainable chemical products--the example of ionic liquids. , 2007, Chemical reviews.

[23]  Kasey Catt,et al.  Mechanical failure modes of chronically implanted planar silicon-based neural probes for laminar recording. , 2015, Biomaterials.

[24]  Mincheol Chang,et al.  Chemical Sensors Based on Highly Conductive Poly(3,4‐ethylenedioxythiophene) Nanorods , 2005 .

[25]  X. Cui,et al.  Poly (3,4-Ethylenedioxythiophene) for Chronic Neural Stimulation , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[26]  R. J. Vetter,et al.  Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[27]  J. Mortimer,et al.  Visual sensations produced by optic nerve stimulation using an implanted self-sizing spiral cuff electrode , 1998, Brain Research.

[28]  M. Abidian,et al.  Conducting‐Polymer Nanotubes for Controlled Drug Release , 2006, Advanced materials.

[29]  P. Kubisa Application of ionic liquids as solvents for polymerization processes , 2004 .

[30]  P. Krack,et al.  Deep-brain stimulation of the subthalamic nucleus or the pars interna of the globus pallidus in Parkinson's disease. , 2001, The New England journal of medicine.

[31]  Shy Shoham,et al.  Robust, automatic spike sorting using mixtures of multivariate t-distributions , 2003, Journal of Neuroscience Methods.

[32]  Christian Bénar,et al.  Conducting Polymer Electrodes for Electroencephalography , 2014, Advanced Healthcare Materials.

[33]  Karen A. Moxon,et al.  Nanostructured surface modification of ceramic-based microelectrodes to enhance biocompatibility for a direct brain-machine interface , 2004, IEEE Transactions on Biomedical Engineering.

[34]  G M Clark,et al.  A study of intra-cochlear electrodes and tissue interface by electrochemical impedance methods in vivo. , 2004, Biomaterials.

[35]  Paras R. Patel,et al.  Ultrasmall implantable composite microelectrodes with bioactive surfaces for chronic neural interfaces. , 2012, Nature materials.

[36]  Daniel R. Merrill,et al.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols , 2005, Journal of Neuroscience Methods.

[37]  Kasey Catt,et al.  Evaluation of poly(3,4-ethylenedioxythiophene)/carbon nanotube neural electrode coatings for stimulation in the dorsal root ganglion , 2015, Journal of neural engineering.

[38]  Partha P. Mitra,et al.  Chronux: A platform for analyzing neural signals , 2010, Journal of Neuroscience Methods.

[39]  Daryl R Kipke,et al.  Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants , 2007, Journal of neural engineering.

[40]  G. Buzsáki,et al.  Gamma (40-100 Hz) oscillation in the hippocampus of the behaving rat , 1995, The Journal of neuroscience : the official journal of the Society for Neuroscience.

[41]  D.B. McCreery,et al.  Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation , 1990, IEEE Transactions on Biomedical Engineering.

[42]  N. S. Ferriols,et al.  Application of a distributed impedance model in the analysis of conducting polymer films , 2000 .

[43]  Yusuke Arima,et al.  Effect of wettability and surface functional groups on protein adsorption and cell adhesion using well-defined mixed self-assembled monolayers. , 2007, Biomaterials.

[44]  X. Cui,et al.  Electrochemical deposition of conducting polymer coatings on magnesium surfaces in ionic liquid. , 2011, Acta biomaterialia.

[45]  Steve M. Potter,et al.  Real-time multi-channel stimulus artifact suppression by local curve fitting , 2002, Journal of Neuroscience Methods.

[46]  D. Szarowski,et al.  Cerebral Astrocyte Response to Micromachined Silicon Implants , 1999, Experimental Neurology.

[47]  J.P. Donoghue,et al.  Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex , 2005, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[48]  Miguel A. L Nicolelis,et al.  A multi-channel whisker stimulator for producing spatiotemporally complex tactile stimuli , 2001, Journal of Neuroscience Methods.

[49]  Kenneth D. Miller,et al.  Cross-channel correlations in tetrode recordings: implications for spike-sorting , 1999, Neurocomputing.

[50]  Patrick A. Tresco,et al.  Impedance characterization of microarray recording electrodes in vitro , 2005, IEEE Transactions on Biomedical Engineering.

[51]  David C. Martin,et al.  Chronic neural recordings using silicon microelectrode arrays electrochemically deposited with a poly(3,4-ethylenedioxythiophene) (PEDOT) film , 2006, Journal of neural engineering.

[52]  Zhaofu Fei,et al.  Cytotoxicity of ionic liquids and precursor compounds towards human cell line HeLa , 2007 .

[53]  Robin C. Ashmore,et al.  An Electrocorticographic Brain Interface in an Individual with Tetraplegia , 2013, PloS one.

[54]  V. Yegnaraman,et al.  PEDOT-Au nanocomposite films for electrochemical sensing of dopamine and uric acid. , 2007, Journal of Nanoscience and Nanotechnology.

[55]  David C. Martin,et al.  Surface modification of neural probes with conducting polymer poly(hydroxymethylated-3,4-ethylenedioxythiophene) and its biocompatibility , 2006, Applied biochemistry and biotechnology.

[56]  A. Gopalan,et al.  Development of a stable cholesterol biosensor based on multi-walled carbon nanotubes-gold nanoparticles composite covered with a layer of chitosan-room-temperature ionic liquid network. , 2009, Biosensors & bioelectronics.

[57]  R.V. Shannon,et al.  A model of safe levels for electrical stimulation , 1992, IEEE Transactions on Biomedical Engineering.

[58]  Michael D Joseph,et al.  Poly(3,4-ethylenedioxythiophene) (PEDOT) polymer coatings facilitate smaller neural recording electrodes , 2011, Journal of neural engineering.

[59]  Dongxue Han,et al.  Electrochemical determination of NADH and ethanol based on ionic liquid-functionalized graphene. , 2010, Biosensors & bioelectronics.

[60]  Jadranka Travas-Sejdic,et al.  The electrochemical growth of highly conductive single PEDOT (conducting polymer):BMIPF6 (ionic liquid) nanowires , 2012 .

[61]  J. Donoghue,et al.  Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates , 2013, Journal of neural engineering.

[62]  Richard G Compton,et al.  Ionic liquid-carbon composite glucose biosensor. , 2008, Biosensors & bioelectronics.

[63]  David C. Martin,et al.  Electrochemical deposition and characterization of poly(3,4-ethylenedioxythiophene) on neural microelectrode arrays , 2003 .

[64]  Patrick A Tresco,et al.  Reducing surface area while maintaining implant penetrating profile lowers the brain foreign body response to chronically implanted planar silicon microelectrode arrays. , 2011, Progress in brain research.