Ventilation of window interpane cavity aimed at a higher temperature of the inner pane
暂无分享,去创建一个
An experimental study of the thermal performance of an air-flow window with triple glazing is described. The measurements were carried out in a climatic chamber under conditions close to a winter season. In the experiments, the temperature and heat-flux distributions on each pane surface, and also the air-temperature distribution over the window height at the middle of the ventilated cavity were determined. The thermal performances of forced and naturally ventilated windows with internal cavities of various thicknesses are reported for a wide range of air-flow rates.
[1] Evyatar Erell,et al. Controlling the transmission of radiant energy through windows: a novel ventilated reversible glazing system , 2000 .
[2] R. F. Boehm. Testing of air-flow windows for evaluation and application , 1980 .
[3] K. H. Haddad,et al. Comparison of the thermal performance of an exhaust-air window and a supply-air window , 1999 .