Thermionic Electron Beam Current and Accelerating Voltage Controller for Gas Ion Sources

Thermionic emission sources are key components of electron impact gas ion sources used in measuring instruments, such as mass spectrometers, ionization gauges, and apparatus for ionization cross-section measurements. The repeatability of the measurements taken with such instruments depends on the stability of the ion current, which is a function, among other things, of the electron beam current and electron accelerating voltage. In this paper, a laboratory thermionic electron beam current and accelerating voltage controller is presented, based on digital algorithm implementation. The average value of the percentage standard deviation of the emission current is 0.021%, and the maximum electron accelerating voltage change versus the emission current is smaller than 0.011% in the full operating range of the emission current. Its application as a trap current or emission current-regulated ion source power supply could be useful in many measuring instruments, such as in microelectromechanical system (MEMS) mass spectrometers as universal gas sensors, where a stable emission current and electron energy are needed.

[1]  S. Hałas,et al.  A novel circuit for independent control of electron energy and emission current of a hot cathode electron source. , 2011, Rapid communications in mass spectrometry : RCM.

[2]  K. Close,et al.  A precision electron emission regulator , 1972 .

[3]  S. Hałas,et al.  Electron emission stabiliser with double negative feedback loop , 1990 .

[4]  S. Shaw,et al.  An integrated circuit based vacuum ionisation gauge meter , 1980 .

[5]  N. Bundaleski,et al.  A review on hot cathode ionisation gauges with focus on a suitable design for measurement accuracy and stability , 2020, Vacuum.

[6]  E. Flaxer Programmable smart electron emission controller for hot filament. , 2011, The Review of scientific instruments.

[7]  Janusz Mroczka,et al.  The cognitive process in metrology , 2013 .

[8]  Jason W. L. Lee,et al.  Absolute electron total ionization cross-sections: molecular analogues of DNA and RNA nucleobase and sugar constituents. , 2014, Physical chemistry chemical physics : PCCP.

[9]  G. Dunn Electron Impact Ionization , 2013, IEEE Transactions on Nuclear Science.

[10]  Bartosz Kania,et al.  Thermionic emission controller with PID algorithm , 2016, 2016 MIXDES - 23rd International Conference Mixed Design of Integrated Circuits and Systems.

[11]  M. Zawadzki Electron-impact ionization cross section of formic acid , 2018, The European Physical Journal D.

[12]  J. Danel,et al.  A MEMS electron impact ion source integrated in a microtime-of-flight mass spectrometer , 2013 .

[13]  R. Kangi,et al.  Remarks concerning about the characteristics of the extractor vacuum gauge and the Quadrupole Mass Spectrometer , 2019, Measurement.

[14]  Fang-Fei Wu,et al.  Tungsten Thermionic Emission as a Gauge for Low Pressures of Cesium Vapor , 2020, Instruments.

[15]  T. Durakiewicz,et al.  Work function variations of incandescent filaments during self-cooling in vacuum , 2006 .

[16]  B. Herbert A circuit for stabilizing the electron current to the anode of a hot-filament device , 1976 .

[17]  J. Sikora Dual application of a biasing system to an electron source with a hot cathode , 2004 .

[18]  Wolfram Knapp,et al.  Control of hot-filament ionization gauge emission current : mathematical model and model-based controller , 1997 .

[19]  T. Durakiewicz Electron emission controller with pulsed heating of filament , 1996 .

[20]  J. Sikora,et al.  System identification of a hot cathode electron source: Time domain approach , 2018, AIP Advances.

[21]  R. Chapman Versatile Wide Range Electron Current Regulator , 1972 .

[22]  D. Barton,et al.  The Brookhaven National Laboratory electron beam ion source for RHIC. , 2010, The Review of scientific instruments.

[23]  S. W. Wright,et al.  MEMS mass spectrometers: the next wave of miniaturization , 2016 .