Evaluation of spatiotemporal organization of persistent atrial fibrillation with time- and frequency-domain measures in humans.

AIMS Areas with complex fractionated electrograms are commonly targeted during ablation of persistent atrial fibrillation (AF). These signals are, however, found in most sampled areas of the left atrium (LA), implying the need for further differentiation. METHODS AND RESULTS Electrograms were recorded over 60 s at eight different LA endocardial sites in 10 patients with persistent AF, using a fully automated algorithm. These were analysed in sequential 2 s segments for activity, mean amplitude, continuous activity percentage, and dominant frequency (DF). All three time-domain measures differed significantly between the LA sites (P < 0.001), whereas DF did not. Activity, continuous activity percentage, and mean activity-amplitude were highest in the mid-coronary sinus and lowest on the posterior wall. In a pairwise analysis, there were significant differences in activity between all locations (P < 0.001-0.044). To visualize the spatiotemporal activity patterns, activity was plotted against amplitude. This revealed distinct activity patterns with large intra- and inter-individual differences. CONCLUSION There are significant activity gradients and distinct activity patterns within the LA in humans with persistent AF. Further work is required, however, to determine whether these findings signify areas with different roles and importance in AF maintenance.

[1]  F. Marchlinski,et al.  Presence of Left-to-Right Atrial Frequency Gradient in Paroxysmal but Not Persistent Atrial Fibrillation in Humans , 2004, Circulation.

[2]  Prashanthan Sanders,et al.  Changes in Atrial Fibrillation Cycle Length and Inducibility During Catheter Ablation and Their Relation to Outcome , 2004, Circulation.

[3]  Michel Haïssaguerre,et al.  The substrate maintaining persistent atrial fibrillation. , 2008, Circulation. Arrhythmia and electrophysiology.

[4]  H. Calkins,et al.  A Conservative Approach to Performing Transseptal Punctures Without the Use of Intracardiac Echocardiography: Stepwise Approach with Real‐Time Video Clips , 2007, Journal of cardiovascular electrophysiology.

[5]  A. Sahakian,et al.  Effect of Bipole Configuration on Atrial Electrograms During Atrial Fibrillation , 1990, Pacing and clinical electrophysiology : PACE.

[6]  Frank Bogun,et al.  Radiofrequency Catheter Ablation of Chronic Atrial Fibrillation Guided by Complex Electrograms , 2007, Circulation.

[7]  M. Allessie,et al.  Configuration of unipolar atrial electrograms during electrically induced atrial fibrillation in humans. , 1997, Circulation.

[8]  A. Harada,et al.  Atrial activation during chronic atrial fibrillation in patients with isolated mitral valve disease. , 1996, The Annals of thoracic surgery.

[9]  D. Shah,et al.  Regional Disparities of Endocardial Atrial Activation in Paroxysmal Atrial Fibrillation , 1996, Pacing and clinical electrophysiology : PACE.

[10]  H. Halperin,et al.  Technique and Results of Pulmonary Vein Angiography in Patients Undergoing Catheter Ablation of Atrial Fibrillation , 2004, Journal of cardiovascular electrophysiology.

[11]  M. Allessie,et al.  Experimental evaluation of Moe's multiple wavelet hypothesis of atrial fibrillation , 1985 .

[12]  Prashanthan Sanders,et al.  Spectral Analysis Identifies Sites of High-Frequency Activity Maintaining Atrial Fibrillation in Humans , 2005, Circulation.

[13]  Shih-Ann Chen,et al.  Consistency of complex fractionated atrial electrograms during atrial fibrillation. , 2008, Heart rhythm.

[14]  F. Sacher,et al.  Catheter Ablation of Long‐Lasting Persistent Atrial Fibrillation: Critical Structures for Termination , 2005, Journal of cardiovascular electrophysiology.

[15]  Javier Moreno,et al.  Activation of Inward Rectifier Potassium Channels Accelerates Atrial Fibrillation in Humans: Evidence for a Reentrant Mechanism , 2006, Circulation.

[16]  Prashanthan Sanders,et al.  Characterization of electrograms associated with termination of chronic atrial fibrillation by catheter ablation. , 2008, Journal of the American College of Cardiology.

[17]  Hugh Calkins,et al.  Initial Experience in the Use of Integrated Electroanatomic Mapping with Three‐Dimensional MR/CT Images to Guide Catheter Ablation of Atrial Fibrillation , 2006, Journal of cardiovascular electrophysiology.

[18]  A. Skanes,et al.  Spatiotemporal periodicity during atrial fibrillation in the isolated sheep heart. , 1998, Circulation.

[19]  David E. Haines,et al.  Frequency domain algorithm for quantifying atrial fibrillation organization to increase defibrillation efficacy , 2001, IEEE Transactions on Biomedical Engineering.

[20]  Sander Verheule,et al.  Arrhythmogenic Substrate of the Pulmonary Veins Assessed by High-Resolution Optical Mapping , 2003, Circulation.

[21]  F. Morady,et al.  Randomized comparison of encircling and nonencircling left atrial ablation for chronic atrial fibrillation. , 2005, Heart rhythm.

[22]  M. Allessie,et al.  Atrial fibrillation begets atrial fibrillation. A study in awake chronically instrumented goats. , 1995, Circulation.

[23]  J Clémenty,et al.  Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. , 1998, The New England journal of medicine.

[24]  S. Ernst,et al.  Nonfluoroscopic endocardial catheter mapping of atrial fibrillation. , 1998, Journal of cardiovascular electrophysiology.

[25]  K. Nademanee,et al.  A new approach for catheter ablation of atrial fibrillation: mapping of the electrophysiologic substrate. , 2004, Journal of the American College of Cardiology.

[26]  Tachapong Ngarmukos,et al.  Clinical outcomes of catheter substrate ablation for high-risk patients with atrial fibrillation. , 2008, Journal of the American College of Cardiology.

[27]  Douglas L. Jones,et al.  Chronic rapid atrial pacing. Structural, functional, and electrophysiological characteristics of a new model of sustained atrial fibrillation. , 1995, Circulation.

[28]  Frank Bogun,et al.  Randomized Evaluation of Right Atrial Ablation After Left Atrial Ablation of Complex Fractionated Atrial Electrograms for Long-Lasting Persistent Atrial Fibrillation , 2008, Circulation. Arrhythmia and electrophysiology.

[29]  Hugh Calkins,et al.  Automated detection and characterization of complex fractionated atrial electrograms in human left atrium during atrial fibrillation. , 2007, Heart rhythm.

[30]  Leora Peltz,et al.  Epicardial Mapping of Chronic Atrial Fibrillation in Patients: Preliminary Observations , 2004, Circulation.

[31]  Jason Ng,et al.  Understanding and Interpreting Dominant Frequency Analysis of AF Electrograms , 2007, Journal of cardiovascular electrophysiology.

[32]  Atul Verma,et al.  A prospective, multicenter evaluation of ablating complex fractionated electrograms (CFEs) during atrial fibrillation (AF) identified by an automated mapping algorithm: acute effects on AF and efficacy as an adjuvant strategy. , 2008, Heart rhythm.

[33]  Jason Ng,et al.  Technical Considerations for Dominant Frequency Analysis , 2007, Journal of cardiovascular electrophysiology.

[34]  M. Mansour,et al.  Left-to-Right Gradient of Atrial Frequencies During Acute Atrial Fibrillation in the Isolated Sheep Heart , 2001, Circulation.