A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending. Part I: D-optimal design for characterization of powder mixing and preliminary spectral data evaluation.

Experimental design, multivariate data acquisition, and analysis in addition to real time monitoring and control through process analyzers, represent an integrated approach for implementation of Process Analytical Technology (PAT) in the pharmaceutical industry. This study, which is the first in a series of three parts, uses an experimental design approach to identify critical factors affecting powder blending. Powder mixtures composed of salicylic acid and lactose were mixed in an 8 qt. V-blender. D-optimal design was employed to characterize the blending process, by studying the effect of humidity, component concentration, and blender speed on mixing end point. Additionally, changes in particle size and density of powder mixtures were examined. A near-infrared (NIR) fiber-optic probe was used to monitor mixing, through multiple optical ports on the blender. Humidity, component concentration, and blender speed were shown to have a significant impact on the blending process. Furthermore, humidity and concentration had a significant effect on particle size and density of powder mixtures. NIRS was sensitive to changes in physicochemical properties of the mixtures, resulting from process variables. Proper selection of NIR spectral preprocessing is of ultimate importance for successful implementation of this technology in the monitoring and control of powder blending and is discussed.

[1]  F. Muzzio,et al.  The use of stratefied sampling of blend and dosage units to demonstrate adequacy of mix for powder blends. , 2003, PDA journal of pharmaceutical science and technology.

[2]  J. Drennen,et al.  Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity. , 2001, Journal of pharmaceutical sciences.

[3]  Fernando J. Muzzio,et al.  An improved powder-sampling tool , 1999 .

[4]  J. Berman,et al.  Blend uniformity and unit dose sampling , 1995 .

[5]  J. A. Hersey,et al.  Perfect powder mixtures , 1977 .

[6]  K. Florey,et al.  Analytical profiles of drug substances and excipients , 1992 .

[7]  Fernando J. Muzzio,et al.  Quantitative characterization of mixing of dry powders in V‐blenders , 1998 .

[8]  H. Venables,et al.  Powder Mixing , 2001, Drug development and industrial pharmacy.

[9]  Ali Nokhodchi,et al.  An overview of the effect of moisture on compaction and compression , 2005 .

[10]  P. K. Aldridge,et al.  On-line monitoring of powder blend homogeneity by near-infrared spectroscopy. , 1996, Analytical chemistry.

[11]  Guidance for Industry PAT — A Framework for Innovative Pharmaceutical Development , Manufacturing , and Quality Assurance , 2004 .

[12]  Jonathan Berman,et al.  Unit Dose Sampling: A Tale of two Thieves , 1996 .

[13]  J. Drennen,et al.  Near-infrared spectroscopic characterization of pharmaceutical powder blends. , 1996, Journal of pharmaceutical and biomedical analysis.

[14]  J. Drennen,et al.  NIR Method Development for Monitoring of Pharmaceutical Powder Blending , 2002 .

[15]  Rodolfo J. Romañach,et al.  Blend uniformity analysis using stream sampling and near infrared spectroscopy , 2008, AAPS PharmSciTech.

[16]  John D. Buehler,et al.  An Evaluation of a Unit-Dose Compacting Sample Thief and a Discussion of Content Uniformity Testing and Blending Validation Issues , 1996 .

[17]  C R Gonzales,et al.  Blend uniformity analysis: validation and in-process testing. Technical Report No. 25. PDA (Parenteral Drug association). , 1997, PDA journal of pharmaceutical science and technology.

[18]  T P Garcia,et al.  Comparison of the performance of two sample thieves for the determination of the content uniformity of a powder blend. , 1998, Pharmaceutical development and technology.