All-optical photoacoustic microscopy (AOPAM) system for remote characterization of biological tissues

Conventional photoacoustic microscopy (PAM) employs light pulses to produce a photoacoustic (PA) effect and detects the resulting acoustic waves using an ultrasound transducer acoustically coupled to the target. The resolution of conventional PAM is limited by the sensitivity and bandwidth of the ultrasound transducer. We investigated a versatile, all-optical PAM (AOPAM) system for characterizing in vivo as well as ex vivo biological specimens. The system employs non-contact interferometric detection of PA signals that overcomes limitations of conventional PAM. A 532-nm pump laser with a pulse duration of 5 ns excites the PA effect in tissue. Resulting acoustic waves produce surface displacements that are sensed using a 532-nm continuous-wave (CW) probe laser in a Michelson interferometer with a 1- GHz bandwidth. The pump and probe beams are coaxially focused using a 50X objective giving a diffraction-limited spot size of 0.48 μm. The phase-encoded probe beam is demodulated using homodyne methods. The detected timedomain signal is time reversed using k-space wave-propagation methods to produce a spatial distribution of PA sources in the target tissue. A minimum surface-displacement sensitivity of 0.19 pm was measured. PA-induced surface displacements are very small; therefore, they impose stringent detection requirements and determine the feasibility of implementing an all-optical PAM in biomedical applications. 3D PA images of ex vivo porcine retina specimens were generated successfully. We believe the AOPAM system potentially is well suited for assessing retinal diseases and other near-surface biomedical applications such as sectionless histology and evaluation of skin burns and pressure or friction ulcers.

[1]  Susan Schneider,et al.  Ranibizumab versus verteporfin for neovascular age-related macular degeneration. , 2006, The New England journal of medicine.

[2]  J. Monchalin Optical Detection of Ultrasound , 1986, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Reinhard Niessner,et al.  Optoacoustic sensor head for depth profiling , 1999 .

[4]  Vadim Backman,et al.  Low-coherent backscattering spectroscopy for tissue characterization. , 2005, Applied optics.

[5]  Zeev Zalevsky,et al.  Demonstration of remote optical measurement configuration that correlates to glucose concentration in blood , 2011, Biomedical optics express.

[6]  Lihong V. Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography. , 2005 .

[7]  Sucbei Moon,et al.  Site-specific multipoint fluorescence measurement system with end-capped optical fibers. , 2011, Applied optics.

[8]  Josef Flammer,et al.  Oxygen and blood flow: players in the pathogenesis of glaucoma , 2008, Molecular vision.

[9]  Bruce J. Tromberg,et al.  The Role of Diffuse Optical Spectroscopy in the Clinical Management of Breast Cancer , 2004, Disease markers.

[10]  B T Cox,et al.  k-space propagation models for acoustically heterogeneous media: application to biomedical photoacoustics. , 2007, The Journal of the Acoustical Society of America.

[11]  Morten la Cour,et al.  Optic nerve oxygenation , 2005, Progress in Retinal and Eye Research.

[12]  R A Kruger,et al.  Photoacoustic ultrasound. , 1994, Medical physics.

[13]  P. Griffiths,et al.  Photoacoustics and Photoacoustic Spectroscopy , 1981 .

[14]  B T Cox,et al.  Fast calculation of pulsed photoacoustic fields in fluids using k-space methods. , 2005, The Journal of the Acoustical Society of America.