Visual Representation of Dynamic Pressure Map on the Digital Human Model of Patient with a Lower Limb Prosthesis

The socket for lower limb prosthesis is the central element of artificial leg that needs to be optimize with the aim to increase comfort and reduce pain. Nowadays, the modeling of this part is completely manual and based on prosthetist skills. The key parameter determining if the socket is properly designed is the pressure distribution in the interface between the skin of residual limb and the internal surface of the socket. In this paper, we expose a method to measure this pressure thought resistive pressure sensors and we illustrate a case study of a transfemoral amputee patient. A visualization tool has been developed to dynamically show pressure data on the 3D model of the residual limb during topic moments of the gait by a color scale. Achieved results and future work will be discussed in the paper.

[1]  Angus McFadyen,et al.  Dynamic interface pressure distributions of two transtibial prosthetic socket concepts. , 2009, Journal of rehabilitation research and development.

[2]  J E Sanders,et al.  Interface pressures and shear stresses at thirteen socket sites on two persons with transtibial amputation. , 1997, Journal of rehabilitation research and development.

[3]  P V S Lee,et al.  Stump/socket pressure profiles of the pressure cast prosthetic socket. , 2003, Clinical biomechanics.

[4]  W D Spence,et al.  Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees—a preliminary study , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  V. C. Roberts,et al.  Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis. , 1998, Medical engineering & physics.

[6]  Ming Zhang,et al.  Pressure distribution at the stump/socket interface in transtibial amputees during walking on stairs, slope and non-flat road. , 2006, Clinical Biomechanics.

[7]  Gh. Pirouzi,et al.  Review of the Socket Design and Interface Pressure Measurement for Transtibial Prosthesis , 2014, TheScientificWorldJournal.

[8]  Caterina Rizzi,et al.  Towards Automatic Gait Assessment by Means of RGB-D Mocap , 2015 .

[9]  G. Xiao,et al.  Erratum to “Characterization of Human Colorectal Cancer MDR1/P-gp Fab Antibody” , 2014, The Scientific World Journal.

[10]  Ak Agarwal Chapter-11 Role of CAD-CAM Technology in Prosthetics and Orthotics , 2013 .

[11]  R Dumas,et al.  Loading applied on prosthetic knee of transfemoral amputee: comparison of inverse dynamics and direct measurements. , 2009, Gait & posture.

[12]  H H Kwee,et al.  A new method for the measurement of normal pressure between amputation residual limb and socket. , 1980, Bulletin of prosthetics research.

[13]  Caterina Rizzi,et al.  Socket virtual design based on low cost hand tracking and haptic devices , 2013, VRCAI '13.