Design and development of a fNIRS system prototype based on SiPM detectors

Functional Near Infrared Spectroscopy (fNIRS) uses near infrared sources and detectors to measure changes in absorption due to neurovascular dynamics in response to brain activation. The use of Silicon Photomultipliers (SiPMs) in a fNIRS system has been estimated potentially able to increase the spatial resolution. Dedicated SiPM sensors have been designed and fabricated by using an optimized process. Electrical and optical characterizations are presented. The design and implementation of a portable fNIRS embedded system, hosting up to 64 IR-LED sources and 128 SiPM sensors, has been carried out. The system has been based on a scalable architecture whose elementary leaf is a flexible board with 16 SiPMs and 4 couples of LEDs each operating at two wavelengths. An ARM based microcontroller has been joined with a multiplexing interface, able to control power supply for the LEDs and collect data from the SiPMs in a time-sharing fashion and with configurable temporal slots. The system will be validated by using a phantom made by materials of different scattering and absorption indices layered to mimic a human head. A preliminary characterization of the optical properties of the single material composing the phantom has been performed using the SiPM in the diffuse radial reflectance measurement technique. The first obtained results confirm the high sensitivity of such kind of detector in the detection of weak light signal even at large distance between the light source and the detector.

[1]  Sebania Libertino,et al.  Silicon photomultiplier device architecture with dark current improved to the ultimate physical limit , 2013 .

[2]  Antonino Parisi,et al.  Responsivity measurements of N-on-P and P-on-N silicon photomultipliers in the continuous wave regime , 2013, Photonics West - Optoelectronic Materials and Devices.

[3]  D. Boas,et al.  Non-invasive neuroimaging using near-infrared light , 2002, Biological Psychiatry.

[4]  Massimo Mazzillo,et al.  N-on-P and P-on-N Silicon Photomultipliers: Responsivity comparison in the continuous wave regime , 2013 .

[5]  L. Leguire,et al.  Using FMRI and FNIRS for localization and monitoring of visual cortex activities , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[6]  Marco Ferrari,et al.  A brief review on the history of human functional near-infrared spectroscopy (fNIRS) development and fields of application , 2012, NeuroImage.

[7]  David A. Boas,et al.  Quantifying tissue hemodynamics by NIRS versus DOT: global versus focal changes in cerebral hemodynamics , 1999, Other Conferences.

[8]  J. Mandeville,et al.  The Accuracy of Near Infrared Spectroscopy and Imaging during Focal Changes in Cerebral Hemodynamics , 2001, NeuroImage.

[9]  R. Gassert,et al.  Silicon photomultipliers for improved detection of low light levels in miniature near-infrared spectroscopy instruments , 2013, Biomedical optics express.

[10]  Isabelle Noiseux,et al.  Reference optical phantoms for diffuse optical spectroscopy. Part 1--Error analysis of a time resolved transmittance characterization method. , 2010, Optics express.

[11]  H. Critchley,et al.  Variability comparison of simultaneous brain near-infrared spectroscopy (NIRS) and functional MRI (fMRI) during visual stimulation , 2011 .

[12]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.

[13]  L. Cosentino,et al.  Silicon Photomultiplier Technology at STMicroelectronics , 2009, IEEE Transactions on Nuclear Science.

[14]  Martin Wolf,et al.  Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications. , 2007, Journal of biomedical optics.

[15]  Ludovico Minati,et al.  Variability comparison of simultaneous brain near-infrared spectroscopy and functional magnetic resonance imaging during visual stimulation , 2011, Journal of medical engineering & technology.

[16]  Yunjie Tong,et al.  Time lag dependent multimodal processing of concurrent fMRI and near-infrared spectroscopy (NIRS) data suggests a global circulatory origin for low-frequency oscillation signals in human brain , 2010, NeuroImage.

[17]  Lihong V. Wang,et al.  Biomedical Optics: Principles and Imaging , 2007 .

[18]  Giuseppe Costantino Giaconia,et al.  Measurements of Silicon Photomultipliers Responsivity in Continuous Wave Regime , 2013, IEEE Transactions on Electron Devices.

[19]  M. Albrow,et al.  Electro-Optical Performances of p-on-n and n-on-p Silicon Photomultipliers , 2012, IEEE Transactions on Electron Devices.

[20]  S R Arridge,et al.  Recent advances in diffuse optical imaging , 2005, Physics in medicine and biology.

[21]  Jerry Workman,et al.  Practical guide to interpretive near-infrared spectroscopy , 2007 .