Quantitative absorption cytometry for measuring red blood cell hemoglobin mass and volume

We present an optical system, called the quantitative absorption cytometer (QAC), to measure the volume and hemoglobin mass of red blood cells flowing through a microfluidic channel. In contrast to clinical hematology analyzers, where cells are sphered in order for both volume and hemoglobin to be measured accurately, the QAC measures cells in their normal physiological shape. Human red blood cells are suspended in a refractive index‐matching absorbing buffer, driven through a microfluidic channel, and imaged using a transmission light microscope onto a color camera. A red and a blue LED illuminate cells and images at each color are used to independently retrieve cell volume and hemoglobin mass. This system shows good agreement with red blood cell indices retrieved by a clinical hematology analyzer and in fact measures a smaller coefficient of variation of hemoglobin concentration. In addition to cell indices, the QAC returns height and mass maps of each measured cell. These quantitative images are valuable for analyzing the detailed morphology of individual cells as well as statistical outliers found in the data. We also measured red blood cells in hypertonic and hypotonic buffers to quantify the correlation between volume and hemoglobin mass under osmotic stress. Because this method is invariant to cell shape, even extremely nonspherical cells in hypertonic buffers can be measured accurately. © 2014 International Society for Advancement of Cytometry

[1]  M. Model,et al.  Measurement of the absorption of concentrated dyes and their use for quantitative imaging of surface topography , 2008, Journal of microscopy.

[2]  Brian McKenna,et al.  Deep ultraviolet mapping of intracellular protein and nucleic acid in femtograms per pixel , 2011, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[3]  Barry R. Masters,et al.  Quantitative Phase Imaging of Cells and Tissues , 2012 .

[4]  S. S. Gorthi,et al.  Microfabricated multiple field of view imaging flow cytometry. , 2012, Lab on a chip.

[5]  Ethan Schonbrun,et al.  Dye exclusion microfluidic microscopy. , 2013, Optics express.

[6]  L. Mahadevan,et al.  Physiological and pathological population dynamics of circulating human red blood cells , 2010, Proceedings of the National Academy of Sciences.

[7]  M. Mir,et al.  Blood testing at the single cell level using quantitative phase and amplitude microscopy , 2011, Biomedical optics express.

[8]  M. Model,et al.  Measurement of the thickness and volume of adherent cells using transmission-through-dye microscopy , 2010, Pflügers Archiv - European Journal of Physiology.

[9]  N. Mohandas,et al.  Red cell membrane: past, present, and future. , 2008, Blood.

[10]  Y. C. Fung,et al.  Improved measurements of the erythrocyte geometry. , 1972, Microvascular research.

[11]  M. L. Gray,et al.  A new method for cell volume measurement based on volume exclusion of a fluorescent dye. , 1983, Cytometry.

[12]  J. Gollub,et al.  Optical heterodyne measurement of cloud droplet size distributions. , 1973, Applied optics.

[13]  L. Ornstein,et al.  Isovolumetric sphering of erythrocytes for more accurate and precise cell volume measurement by flow cytometry. , 1983, Cytometry.

[14]  R. Barer,et al.  Refractive Index of Concentrated Protein Solutions , 1954, Nature.

[15]  M. Friebel,et al.  Model function to calculate the refractive index of native hemoglobin in the wavelength range of 250-1100 nm dependent on concentration. , 2006, Applied optics.

[16]  YongKeun Park,et al.  Spectroscopic phase microscopy for quantifying hemoglobin concentrations in intact red blood cells , 2009, BiOS.

[17]  A. Mcfarlane,et al.  An ultracentrifugal investigation of the serum proteins. , 1935, The Biochemical journal.

[18]  P. Hebert,et al.  From Pixels to Picograms , 2002, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[19]  M. H. Metz,et al.  Flow-cytometric light scattering measurement of red blood cell volume and hemoglobin concentration. , 1985, Applied optics.

[20]  R. Skalak,et al.  Deformation of Red Blood Cells in Capillaries , 1969, Science.

[21]  S. S. Gorthi,et al.  Phase imaging flow cytometry using a focus-stack collecting microscope. , 2012, Optics letters.

[22]  M. Daimon,et al.  Measurement of the refractive index of distilled water from the near-infrared region to the ultraviolet region. , 2007, Applied optics.

[23]  William E. Ortyn,et al.  Cellular image analysis and imaging by flow cytometry. , 2007, Clinics in laboratory medicine.

[24]  Clinical Hematology , 1962 .

[25]  P. Marquet,et al.  Comparative study of human erythrocytes by digital holographic microscopy, confocal microscopy, and impedance volume analyzer , 2008, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[26]  T. Somervaille Disorders of Hemoglobin: Genetics, Pathophysiology, and Clinical Management , 2001 .