Reduction of variable-truncation artifacts from beam occlusion during in situ x-ray tomography

Many in situ X-ray tomography studies require experimental rigs which may partially occlude the beam and cause parts of the projection data to be missing. In a study of fluid flow in porous chalk using a percolation cell with four metal bars drastic streak artifacts arise in the filtered backprojection (FBP) reconstruction at certain orientations. Projections with non-trivial variable truncation caused by the metal bars are the source of these variable-truncation artifacts. To understand the artifacts a mathematical model of variable-truncation data as function of metal bar radius and distance to sample is derived and verified numerically and with experimental data. The model accurately describes the arising variable-truncation artifacts across simulated variations of the experimental setup. Three variable-truncation artifact-reduction methods are proposed, all aimed at addressing sinogram discontinuities that are shown to be the source of the streaks. The “Reduction to Limited Angle” (RLA) method simply keeps only non-truncated projections; the “Detector-Directed Smoothing” (DDS) method smooths the discontinuities while the “Reflexive Boundary Condition” (RBC) method enforces a zero derivative at the discontinuities. Experimental results using both simulated and real data show that the proposed methods effectively reduce variable-truncation artifacts. The RBC method is found to provide the best artifact reduction and preservation of image features using both visual and quantitative assessment. The analysis and artifact-reduction methods are designed in context of FBP reconstruction motivated by computational efficiency practical for large, real synchrotron data. While a specific variable-truncation case is considered, the proposed methods can be applied to general data cut-offs arising in different in situ X-ray tomography experiments.

[2]  W. Ludwig,et al.  Three-dimensional in situ observations of short fatigue crack growth in magnesium , 2011 .

[3]  T. Marrow,et al.  In-situ X-ray computed tomography characterisation of 3D fracture evolution and image-based numerical homogenisation of concrete , 2017 .

[4]  Dimitris Mihailidis,et al.  Computed Tomography: From Photon Statistics to Modern Cone-Beam CT , 2008 .

[5]  Yoram Bresler,et al.  Globally convergent edge-preserving regularized reconstruction: an application to limited-angle tomography , 1998, IEEE Trans. Image Process..

[6]  Jurgen Frikel,et al.  On Artifacts in Limited Data Spherical Radon Transform: Curved Observation Surface , 2014 .

[7]  F. Boas,et al.  CT artifacts: Causes and reduction techniques , 2012 .

[8]  Ge Wang,et al.  Metal Artifact Reduction in CT: Where Are We After Four Decades? , 2016, IEEE Access.

[9]  Xiaochuan Pan,et al.  Image reconstruction in regions-of-interest from truncated projections in a reduced fan-beam scan , 2005, Physics in medicine and biology.

[10]  Shyamprasad Karagadde,et al.  Time-resolved synchrotron tomographic quantification of deformation during indentation of an equiaxed semi-solid granular alloy , 2016 .

[11]  S. Osher,et al.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM) , 2011, Inverse problems.

[12]  M. Persson,et al.  Total variation norm for three-dimensional iterative reconstruction in limited view angle tomography , 2001, Physics in medicine and biology.

[13]  D. Fleischmann,et al.  Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. , 2011, Radiology.

[14]  F. Noo,et al.  A two-step Hilbert transform method for 2D image reconstruction. , 2004, Physics in medicine and biology.

[15]  Kees Joost Batenburg,et al.  DART: A Practical Reconstruction Algorithm for Discrete Tomography , 2011, IEEE Transactions on Image Processing.

[16]  Fmw Frans Kanters,et al.  Towards object-based image editing , 2007 .

[17]  Thorsten M. Buzug Computed Tomography: From Photon Statistics to Modern Cone-Beam CT , 2010 .

[18]  Matti Lassas,et al.  Wavelet-based reconstruction for limited-angle X-ray tomography , 2006, IEEE Transactions on Medical Imaging.

[19]  M Müller,et al.  Truncation artifacts in tomographic reconstructions from projections. , 1996, Applied optics.

[20]  Kentaro Uesugi,et al.  Development of fast (sub‐minute) micro‐tomography , 2010 .

[21]  Jacob Geleijns,et al.  Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. , 2010, Medical physics.

[22]  Jurgen Frikel,et al.  Sparse regularization in limited angle tomography , 2011, 1109.0385.

[23]  Dianne P. O'Leary,et al.  Deblurring Images: Matrices, Spectra and Filtering , 2006, J. Electronic Imaging.

[24]  V. Cnudde,et al.  A pore-scale study of fracture dynamics in rock using X-ray micro-CT under ambient freeze-thaw cycling. , 2015, Environmental science & technology.

[25]  E. Sidky,et al.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization , 2008, Physics in medicine and biology.

[26]  Eric Todd Quinto,et al.  Characterization and reduction of artifacts in limited angle tomography , 2013 .

[27]  Linh V. Nguyen How strong are streak artifacts in limited angle computed tomography? , 2014, 1407.3037.

[28]  P. Suetens,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[29]  Patrick Dupont,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998 .

[30]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.