Combination of confocal principle and aperture stop separation improves suppression of crystalline lens fluorescence in an eye model.

Fluorescence lifetime imaging ophthalmoscopy (FLIO) is a new technique to detect changes in the human retina. The autofluorescence decay over time, generated by endogenous fluorophores, is measured in vivo. The strong autofluorescence of the crystalline lens, however, superimposes the intensity decay of the retina fluorescence, as the confocal principle is not able to suppress it sufficiently. Thus, the crystalline lens autofluorescence causes artifacts in the retinal fluorescence lifetimes determined from the intensity decays. Here, we present a new technique to suppress the autofluorescence of the crystalline lens by introducing an annular stop into the detection light path, which we call Schweitzer's principle. The efficacy of annular stops with an outer diameter of 7 mm and inner diameters of 1 to 5 mm are analyzed in an experimental setup using a model eye based on fluorescent dyes. Compared to the confocal principle, Schweitzer's principle with an inner diameter of 3 mm is able to reduce the simulated crystalline lens fluorescence to 4%, while 42% of the simulated retina fluorescence is preserved. Thus, we recommend the implementation of Schweitzer's principle in scanning laser ophthalmoscopes used for fundus autofluorescence measurements, especially the FLIO device, for improved image quality.

[1]  P. Walter,et al.  Fundus near infrared fluorescence correlates with fundus near infrared reflectance. , 2006, Investigative ophthalmology & visual science.

[2]  Sebastian Wolf,et al.  Fluorescence lifetime imaging in retinal artery occlusion. , 2015, Investigative ophthalmology & visual science.

[3]  Dietrich Schweitzer,et al.  Retinal fluorescence lifetime imaging ophthalmoscopy measures depend on the severity of Alzheimer's disease , 2015, Acta ophthalmologica.

[4]  Laura Marcu,et al.  Fluorescence Lifetime Techniques in Medical Applications , 2012, Annals of Biomedical Engineering.

[5]  D. Schweitzer,et al.  Towards metabolic mapping of the human retina , 2007, Microscopy research and technique.

[6]  Martin Hammer,et al.  Fluorescence lifetime imaging ophthalmoscopy in type 2 diabetic patients who have no signs of diabetic retinopathy , 2015, Journal of biomedical optics.

[7]  T. Aleman,et al.  Reduced-illuminance autofluorescence imaging in ABCA4-associated retinal degenerations. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[8]  R. Augsten,et al.  Fluorescence lifetime imaging ophthalmoscopy in glaucoma , 2014, Graefe's Archive for Clinical and Experimental Ophthalmology.

[9]  M. Katz,et al.  Fluorophores of the human retinal pigment epithelium: separation and spectral characterization. , 1988, Experimental eye research.

[10]  W. Becker Fluorescence lifetime imaging – techniques and applications , 2012, Journal of microscopy.

[11]  Dietrich Schweitzer,et al.  Ocular fundus auto-fluorescence observations at different wavelengths in patients with age-related macular degeneration and diabetic retinopathy , 2007, Graefe's Archive for Clinical and Experimental Ophthalmology.

[12]  Dietrich Schweitzer,et al.  FLIMX: A Software Package to Determine and Analyze the Fluorescence Lifetime in Time-Resolved Fluorescence Data from the Human Eye , 2015, PloS one.

[13]  V. Greenstein,et al.  Comparison of near-infrared and short-wavelength autofluorescence in retinitis pigmentosa. , 2013, Investigative ophthalmology & visual science.

[14]  F. Delori,et al.  Near-infrared autofluorescence imaging of the fundus: visualization of ocular melanin. , 2006, Investigative ophthalmology & visual science.

[15]  D. Schweitzer,et al.  In vivo measurement of time-resolved autofluorescence at the human fundus. , 2004, Journal of biomedical optics.

[16]  P. Sharp,et al.  The scanning laser ophthalmoscope. , 1997, Physics in medicine and biology.

[17]  Dietrich Schweitzer,et al.  Impact of Macular Pigment on Fundus Autofluorescence Lifetimes. , 2015, Investigative ophthalmology & visual science.

[18]  S. Wolf,et al.  Fluorescence Lifetime Imaging in Stargardt Disease: Potential Marker for Disease Progression. , 2016, Investigative ophthalmology & visual science.

[19]  H. Pau,et al.  Different regional changes of fluorescence spectra of clear human lenses and nuclear cataracts , 1993, Graefe's Archive for Clinical and Experimental Ophthalmology.

[20]  D. Schweitzer,et al.  [Limits of the confocal laser-scanning technique in measurements of time-resolved autofluorescence of the ocular fundus]. , 2005, Biomedizinische Technik. Biomedical engineering.

[21]  A. Bird,et al.  FUNDUS AUTOFLUORESCENCE IMAGING: Review and Perspectives , 2008, Retina.

[22]  D. Schweitzer,et al.  Time-resolved autofluorescence imaging of human donor retina tissue from donors with significant extramacular drusen. , 2012, Investigative ophthalmology & visual science.

[23]  M Hammer,et al.  [Time-resolved autofluorescence in retinal vascular occlusions]. , 2010, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[24]  F. Fitzke,et al.  Localisation and significance of in vivo near-infrared autofluorescent signal in retinal imaging , 2010, British Journal of Ophthalmology.