ICA-based reduction of electromyogenic artifacts in EEG data: Comparison with and without EMG data

Analysis of electroencephalography (EEG) recorded during movement is often aggravated or even completely hindered by electromyogenic artifacts. This is caused by the overlapping frequencies of brain and myogenic activity and the higher amplitude of the myogenic signals. One commonly employed computational technique to reduce these types of artifacts is Independent Component Analysis (ICA). ICA estimates statistically independent components (ICs) that, when linearly combined, closely match the input (sensor) data. Removing the ICs that represent artifact sources and re-mixing the sources returns the input data with reduced noise activity. ICs of real-world data are usually not perfectly separated, actual sources, but a mixture of these sources. Adding additional input signals, predominantly generated by a single IC that is already part of the original sensor data, should increase that IC's separability. We conducted this study to evaluate this concept for ICA-based electromyogenic artifact reduction in EEG using EMG signals as additional inputs. To acquire the appropriate data we worked with nine human volunteers. The EEG and EMG were recorded while the study volunteers performed seven exercises designed to produce a wide range of representative myogenic artifacts. To evaluate the effect of the EMG signals we estimated the sources of each dataset once with and once without the EMG data. The ICs were automatically classified as either `myogenic' or `non-myogenic'. We removed the former before back projection. Afterwards we calculated an objective measure to quantify the artifact reduction and assess the effect of including EMG signals. Our study showed that the ICA-based reduction of electromyogenic artifacts can be improved by including the EMG data of artifact-inducing muscles. This approach could prove beneficial for locomotor disorder research, brain-computer interfaces, neurofeedback, and most other areas where brain activity during movement has to be analyzed.

[1]  Kenneth Kreutz-Delgado,et al.  AMICA : An Adaptive Mixture of Independent Component Analyzers with Shared Components , 2011 .

[2]  Bjoern M. Eskofier,et al.  Generic Features for Biosignal Classification , 2012 .

[3]  Wim Van Paesschen,et al.  Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram , 2006, IEEE Transactions on Biomedical Engineering.

[4]  D. Chakrabarti,et al.  A fast fixed - point algorithm for independent component analysis , 1997 .

[5]  Björn Eskofier,et al.  Comparison of the AMICA and the InfoMax algorithm for the reduction of electromyogenic artifacts in EEG data , 2013, 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[6]  J. Wolpaw,et al.  EMG contamination of EEG: spectral and topographical characteristics , 2003, Clinical Neurophysiology.

[7]  E Donchin,et al.  A new method for off-line removal of ocular artifact. , 1983, Electroencephalography and clinical neurophysiology.

[8]  Trevor Thompson,et al.  EEG applications for sport and performance. , 2008, Methods.

[9]  Daniel P. Ferris,et al.  Electrocortical activity is coupled to gait cycle phase during treadmill walking , 2011, NeuroImage.

[10]  Tzyy-Ping Jung,et al.  Independent Component Analysis of Electroencephalographic Data , 1995, NIPS.

[11]  J. Doust,et al.  A 1% treadmill grade most accurately reflects the energetic cost of outdoor running. , 1996, Journal of sports sciences.

[12]  Terrence J. Sejnowski,et al.  An Information-Maximization Approach to Blind Separation and Blind Deconvolution , 1995, Neural Computation.

[13]  Bjoern M. Eskofier,et al.  SVM for Semi-automatic Selection of ICA Components of Electromyogenic Artifacts in EEG Data , 2014 .

[14]  Arnaud Delorme,et al.  EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis , 2004, Journal of Neuroscience Methods.

[15]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[16]  D. Vernon Can Neurofeedback Training Enhance Performance? An Evaluation of the Evidence with Implications for Future Research , 2005, Applied psychophysiology and biofeedback.

[17]  Daniel P. Ferris,et al.  Removal of movement artifact from high-density EEG recorded during walking and running. , 2010, Journal of neurophysiology.

[18]  J. D. Munck,et al.  The electric resistivity of human tissues (100 Hz-10 MHz): a meta-analysis of review studies. , 1999, Physiological measurement.

[19]  W Brent Edwards,et al.  When does a gait transition occur during human locomotion? , 2007, Journal of sports science & medicine.

[20]  T. Sejnowski,et al.  Linking brain, mind and behavior. , 2008, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[21]  Vinzenz von Tscharner,et al.  Methodological aspects of EEG and body dynamics measurements during motion , 2014, Front. Hum. Neurosci..