Comparison of 2 electric toothbrushes in plaque-removing ability. Professional and supervised brushing.

The purpose of the present study was to compare the Braun Plak Control (D7) and Philips HP 500 (MM) in their plaque removing efficacy. Furthermore the brushing force applied by the panelist on the brush-head with both these brushes was evaluated. For this study, 35 university students (non-dental) were selected. The study consisted of 3 experiments. Prior to each experiment, all subjects were asked to abstain from all oral hygiene procedures for at least 48 h. In Exp. I, the efficacy of toothbrushing was studied when one of the investigators brushed the teeth of the panellists. In Exp. II, the efficacy of the brushing was studied after the students had received a professional instruction. In Exp. III, the brushing force used during a single brushing exercise was evaluated. The available time for the brushing amounted to a total of 2 min per mouth. Dental plaque was evaluated by means of the Silness and Löe and Quigley and Hein plaque indices assessed at 6 sites per tooth. Results showed that both in Exp. I and Exp. II, the D7 removed significantly more plaque than the MM electric toothbrush. The plaque reduction assessed according to Silness and Löe in Exp. I was for the D7, 1.07 and for the MM, 0.78. In Exp. II, the reduction was 1.08 and 0.88, respectively. The results of Exp. III show that the mean brushing force was comparable for both brushes (D7 = 173 g, MM = 175 g). All 35 subjects were allowed to choose one electric toothbrush as compensation for their participation.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  S. Zimmerman,et al.  Proposed guidelines for American Dental Association acceptance of products for professional, non-surgical treatment of adult periodontitis. Task Force on Design and Analysis in Dental and Oral Research. , 1994, Journal of periodontal research.

[2]  K. Stoltze,et al.  Comparison of a manual and a new electric toothbrush for controlling plaque and gingivitis. , 1994, Journal of clinical periodontology.

[3]  M. Timmerman,et al.  The long-term effect of an oscillating/rotating electric toothbrush on gingivitis. An 8-month clinical study. , 1994, Journal of clinical periodontology.

[4]  G A Van der Weijden,et al.  A comparative study of electric toothbrushes for the effectiveness of plaque removal in relation to toothbrushing duration. Timerstudy. , 1993, Journal of clinical periodontology.

[5]  M. Timmerman,et al.  The plaque-removing efficacy of an oscillating/rotating toothbrush. A short-term study. , 1993, Journal of clinical periodontology.

[6]  A. Volpe,et al.  Comparative anticalculus effect of dentifrices containing 1.30% soluble pyrophosphate with and without a copolymer. , 1990, The Journal of clinical dentistry.

[7]  J. Ainamo,et al.  The effect of toothbrush grip on gingival abrasion and plaque removal during toothbrushing. , 1987, Journal of clinical periodontology.

[8]  J. Ainamo,et al.  Frequency of gingival lesions after standardized brushing as related to stiffness of toothbrush and abrasiveness of dentifrice. , 1984, Journal of clinical periodontology.

[9]  J. Ainamo,et al.  Identification of soft tissue brushing lesions. A clinical and scanning electron microscopic study. , 1982, Journal of clinical periodontology.

[10]  H. Löe Mechanical and chemical control of dental plaque. , 1979, Journal of clinical periodontology.

[11]  A. Saffir,et al.  The Measurement of the Effect of Toothbrushes on Soft Tissue Abrasion , 1977, Journal of dental research.

[12]  I Glickman,et al.  Reduced plaque formation by the chloromethyl analogue of victamine C. , 1970, Journal of periodontology.

[13]  H. Löe,et al.  PERIODONTAL DISEASE IN PREGNANCY. II. CORRELATION BETWEEN ORAL HYGIENE AND PERIODONTAL CONDTION. , 1964, Acta odontologica Scandinavica.

[14]  G A QUIGLEY,et al.  Comparative cleansing efficiency of manual and power brushing. , 1962, Journal of the American Dental Association.

[15]  S. Arnim,et al.  Dentifrice Abrasion—Report of a Case* , 1961 .