A flexible stereo calibration for a structured-light profilometer

The paper proposes a novel method for the calibration of a 3-D scanner composed of a camera and a projector. The proposed method models the projector as a second camera, and then reduces the calibration of a camera - projector pair into the calibration of a stereo pair of cameras, with advantages in terms of simplicity, flexibility, accuracy and availability of known solutions. This approach is very advantageous overall for those scanners whose camera and projector can be moved by the operators in order to achieve the most suitable configuration for the specific object under measurement. Results are shown for different organizations of the procedure and for different geometrical configurations. The uncertainty of calibrated parameters is also discussed.

[1]  Kenichi Kanatani,et al.  Triangulation from Two Views Revisited: Hartley-Sturm vs. Optimal Correction , 2008, BMVC.

[2]  C D'Argenio,et al.  A simplified procedure for the calibration of a fringe pattern profilometer , 2009, 2009 IEEE Instrumentation and Measurement Technology Conference.

[3]  Thomas Luhmann 3D imaging: how to achieve highest accuracy , 2011, Optical Metrology.

[4]  Janne Heikkilä,et al.  Geometric Camera Calibration Using Circular Control Points , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[5]  G. Godin,et al.  An Energy Formulation for Establishing the Correspondence Used in Projector Calibration , 2008 .

[6]  Wei Gao,et al.  Flexible Calibration of a Portable Structured Light System through Surface Plane , 2008 .

[7]  O. Faugeras Three-dimensional computer vision: a geometric viewpoint , 1993 .

[8]  C. Liguori,et al.  Stereo calibration for a camera - projector pair , 2010, 2010 IEEE Instrumentation & Measurement Technology Conference Proceedings.

[9]  Bernhard P. Wrobel,et al.  Multiple View Geometry in Computer Vision , 2001 .

[10]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[11]  Andrew W. Fitzgibbon,et al.  Direct Least Square Fitting of Ellipses , 1999, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  K. Reichard,et al.  Calibration-based phase-shifting projected fringe profilometry for accurate absolute 3D surface profile measurement , 2003 .

[13]  Werner Bösemann Industrial photogrammetry: challenges and opportunities , 2011, Optical Metrology.

[14]  C. Liguori,et al.  An easy and accurate calibration procedure for 3-D shape measurement system based on phase-shifting projected fringe profilometry , 2008, 2008 IEEE Instrumentation and Measurement Technology Conference.

[15]  Peisen S. Huang,et al.  Novel method for structured light system calibration , 2006 .

[16]  Neil A. Thacker,et al.  An Evaluation of the Performance of RANSAC Algorithms for Stereo Camera Calibrarion , 2000, BMVC.