Noise Level and Similarity Analysis for Computed Tomographic Thoracic Image with Fast Non-Local Means Denoising Algorithm

Although conventional denoising filters have been developed for noise reduction from digital images, these filters simultaneously cause blurring in the images. To address this problem, we proposed the fast non-local means (FNLM) denoising algorithm which would preserve the edge information of objects better than conventional denoising filters. In this study, we obtained thoracic computed tomography (CT) images from a male adult mesh (MASH) phantom modeled by computer and a five-year-old phantom to perform both the simulation study and the practical study. Subsequently, the FNLM denoising algorithm and conventional denoising filters, such as the Gaussian, median, and Wiener filters, were applied to the MASH phantom image adding Gaussian noise with a standard deviation of 0.002 and practical CT images. Finally, the results were compared quantitatively in terms of the coefficient of variation (COV), contrast-to-noise ratio (CNR), peak signal-to-noise ratio (PSNR), and correlation coefficient (CC). The results showed that the FNLM denoising algorithm was more efficient than the conventional denoising filters. In conclusion, through the simulation study and the practical study, this study demonstrated the feasibility of the FNLM denoising algorithm for noise reduction from thoracic CT images.

[1]  M E Phelps,et al.  Correlation of effective atomic number and electron density with attenuation coefficients measured with polychromatic x rays. , 1975, Radiology.

[2]  Manoj Gupta,et al.  Performance Comparison of Median and Wiener Filter in Image De-noising , 2010 .

[3]  J. W. Vieira,et al.  FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: II. Dosimetric calculations , 2010, Physics in medicine and biology.

[4]  L. Tanoue,et al.  Reduced lung cancer mortality with low-dose computed tomographic screening , 2011 .

[5]  D. McCauley,et al.  Low-dose CT of the lungs: preliminary observations. , 1990, Radiology.

[6]  K. Stierstorfer,et al.  Density and atomic number measurements with spectral x-ray attenuation method , 2003 .

[7]  Gnanambal Ilango,et al.  NEW HYBRID FILTERING TECHNIQUES FOR REMOVAL OF GAUSSIAN NOISE FROM MEDICAL IMAGES , 2011 .

[8]  Cynthia H McCollough,et al.  Managing radiation use in medical imaging: a multifaceted challenge. , 2011, Radiology.

[9]  A. Sakurada,et al.  Computed tomographic image comparison between mediastinal and lung windows provides possible prognostic information in patients with small peripheral lung adenocarcinoma. , 2002, The Journal of thoracic and cardiovascular surgery.

[10]  Jin Wang,et al.  A Robust and Fast Non-Local Means Algorithm for Image Denoising , 2007, 2007 10th IEEE International Conference on Computer-Aided Design and Computer Graphics.

[11]  C. Gatsonis,et al.  Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening , 2012 .

[12]  V F Cassola,et al.  FASH and MASH: female and male adult human phantoms based on polygon mesh surfaces: I. Development of the anatomy , 2010, Physics in medicine and biology.

[13]  C. Herrmann,et al.  X-ray scattering in single- and dual-source CT. , 2007, Medical physics.

[14]  Filippo Attivissimo,et al.  Dosimetric Characterization and Image Quality Assessment in Breast Tomosynthesis , 2017, IEEE Transactions on Instrumentation and Measurement.

[15]  Djemel Ziou,et al.  Image Quality Metrics: PSNR vs. SSIM , 2010, 2010 20th International Conference on Pattern Recognition.

[16]  Enmin Song,et al.  A fast non-local means algorithm based on integral image and reconstructed similar kernel , 2018, International Symposium on Multispectral Image Processing and Pattern Recognition.

[17]  M. Mukaka,et al.  Statistics corner: A guide to appropriate use of correlation coefficient in medical research. , 2012, Malawi medical journal : the journal of Medical Association of Malawi.

[18]  Lili Tian,et al.  Inferences on the common coefficient of variation , 2005, Statistics in medicine.

[19]  Benoît Naegel,et al.  SNR enhancement of highly-accelerated real-time cardiac MRI acquisitions based on non-local means algorithm , 2009, Medical Image Anal..

[20]  Seong Jin Park,et al.  Noise removal in medical mammography images using fast non-local means denoising algorithm for early breast cancer detection: a phantom study , 2019 .

[21]  C A Kelsey,et al.  CT scanning: patterns of use and dose , 2000, Journal of radiological protection : official journal of the Society for Radiological Protection.

[22]  Bertram J Jobst,et al.  Similarities in the Computed Tomography Appearance in α1-Antitrypsin Deficiency and Smoking-Related Chronic Obstructive Pulmonary Disease in a Smoking Collective , 2018, Respiration.

[23]  Eunsoo Seo,et al.  Feasibility of fast non-local means noise reduction algorithm in magnetic resonance imaging using 1.5 and 3.0 T with diffusion-weighted image technique , 2019 .

[24]  Mahdi Ghorbani,et al.  Evaluation of effective dose and entrance skin dose in digital radiology , 2020, Polish Journal of Medical Physics and Engineering.

[25]  Myonggeun Yoon,et al.  Feasibility of newly designed fast non local means (FNLM)-based noise reduction filter for X-ray imaging: A simulation study , 2018 .

[26]  Kai Wang,et al.  Non-local means denoising algorithm accelerated by GPU , 2009, International Symposium on Multispectral Image Processing and Pattern Recognition.

[27]  C D Claussen,et al.  Iterative Reconstruction in Head CT: Image Quality of Routine and Low-Dose Protocols in Comparison with Standard Filtered Back-Projection , 2012, American Journal of Neuroradiology.

[28]  Jacob D. Furst,et al.  Texture versus shape analysis for lung nodule similarity in computed tomography studies , 2008, SPIE Medical Imaging.

[29]  Wilfried Philips,et al.  A fast non-local image denoising algorithm , 2008, Electronic Imaging.

[30]  Min Cheol Han,et al.  Conversion of ICRP male reference phantom to polygon-surface phantom , 2013, Physics in medicine and biology.

[31]  Moon Gi Kang,et al.  Poisson–Gaussian Noise Analysis and Estimation for Low-Dose X-ray Images in the NSCT Domain , 2018, Sensors.

[32]  Filippo Attivissimo,et al.  Dose Optimization in Chest Radiography: System and Model Characterization via Experimental Investigation , 2014, IEEE Transactions on Instrumentation and Measurement.

[33]  Hyun Woo Goo,et al.  CT Radiation Dose Optimization and Estimation: an Update for Radiologists , 2011, Korean journal of radiology.

[34]  Jean-Michel Morel,et al.  A non-local algorithm for image denoising , 2005, 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05).

[35]  Timothy P Szczykutowicz,et al.  A method to extract image noise level from patient images in CT , 2017, Medical physics.

[36]  Pierrick Coupé,et al.  Fast Non Local Means Denoising for 3D MR Images , 2006, MICCAI.

[37]  Jacob Geleijns,et al.  Dose and perceived image quality in chest radiography. , 2009, European journal of radiology.