Neutron spectrum parameters in irradiation channels of the Nigeria Research Reactor-1 (NIRR-1) for the k0-NAA standardization
暂无分享,去创建一个
SummaryThe first nuclear research reactor in Nigeria has been commissioned for neutron activation analysis and limited radioisotope production. In order to extend its utilization to include the k0-standardization method, the following neutron spectrum parameters in inner and outer irradiation channels were determined by the “Cd-ratio for multi-monitor method”: the thermal-to-epithermal flux ratio, f, and the epithermal flux shape factor, α. Neutron spectrum parameters determined in the inner irradiation channel B2, are: α = -0.052±0.002 and f = 19.2±0.5. For the outer irradiation channel B4, the neutron spectrum parameters were found to be α = +0.029±0.003 and f = 48.3±3.3. The results are compared with the neutron spectrum parameters of other reactor facilities with similar core configuration such as the Slowpoke and Miniature Neutron Source Reactor facilities available in the literature.