A Portable Eddy Covariance System for the Measurement of Ecosystem–Atmosphere Exchange of CO2, Water Vapor, and Energy

Abstract To facilitate the study of flux heterogeneity within a region, the authors have designed and field-tested a portable eddy covariance system to measure exchange of CO2, water vapor, and energy between the land surface and the atmosphere. The combination of instrumentation used in this system allows high precision flux measurements without requiring on-site infrastructure such as prepositioned towers or line power. In addition, the system contains sensors to measure a suit of soil, climatic, and energy-related parameters that are needed to quality control the fluxes and to characterize the flux footprint. The physical design and instrument packaging used in the system allows for simple transport (fits in a standard minivan) and for rapid deployment with a minimal number of field personnel (usually less than a day for one person). The power requirement for the entire system (instruments and data loggers) is less than 35 W, which is provided by a companion solar power system. Side-by-side field compa...

[1]  J. Wyngaard,et al.  How Close is Close Enough When Measuring Scalar Fluxes with Displaced Sensors , 1997 .

[2]  Frans T. M. Nieuwstadt,et al.  Temperature measurement with a sonic anemometer and its application to heat and moisture fluxes , 1983 .

[3]  T. Meyers,et al.  Correction Of Eddy-Covariance Measurements Incorporating Both Advective Effects And Density Fluxes , 2000, Boundary-Layer Meteorology.

[4]  R. L. Desjardins,et al.  A Micrometeorological Facility for Eddy Flux Measurements of CO2 and H2O , 1989 .

[5]  Tilden P. Meyers,et al.  An open path, fast response infrared absorption gas analyzer for H2O and CO2 , 1992 .

[6]  D. Bremer,et al.  MEASUREMENT AND MODELING OF SOIL CO2 FLUX IN A TEMPERATE GRASSLAND UNDER MOWED AND BURNED REGIMES , 2002 .

[7]  F. Chapin,et al.  A Comparative Approach to Regional Variation in Surface Fluxes Using Mobile Eddy Correlation Towers , 1997 .

[8]  Üllar Rannik,et al.  Autoregressive filtering versus linear detrending in estimation of fluxes by the eddy covariance method , 1999 .

[9]  E. K. Webb,et al.  Correction of flux measurements for density effects due to heat and water vapour transfer , 1980 .

[10]  Tilden P. Meyers,et al.  A comparison of summertime water and CO2 fluxes over rangeland for well watered and drought conditions , 2001 .

[11]  W. Oechel,et al.  Energy balance closure at FLUXNET sites , 2002 .

[12]  C. J. Moore Frequency response corrections for eddy correlation systems , 1986 .

[13]  R. C. Weast Handbook of chemistry and physics , 1973 .