Megavoltage CT on a tomotherapy system.

A megavoltage computed tomography (MVCT) system was developed on the University of Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and collect transmission data without any bounds on delivered dose. Scan times as low as 12 s per slice are possible, and scans were run with linac output rates of 100 MU min(-1), although the system can be tuned to deliver arbitrarily low dose rates. Images were reconstructed with clinically reasonable doses ranging from 8 to 12 cGy. These images delineate contrasts below 2% and resolutions of 3.0 mm. Thus, the MVCT image quality of this system should be sufficient for verifying the patient's position and anatomy prior to radiotherapy. Additionally, synthetic data were used to test the potential for improved MVCT contrast using maximum-likelihood (ML) reconstruction. Specifically, the maximum-likelihood expectation-maximization (ML-EM) algorithm and a transmission ML algorithm were compared with filtered backprojection (FBP). It was found that for expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms. For significantly lower doses, some quantitative improvement is achieved through ML reconstruction. Nonetheless, the image quality at those lower doses is not satisfactory for radiotherapy verification.

[1]  Irene A. Stegun,et al.  Handbook of Mathematical Functions. , 1966 .

[2]  R. Brooks,et al.  Statistical limitations in x-ray reconstructive tomography. , 1976, Medical physics.

[3]  Albert Macovski,et al.  A Maximum Likelihood Approach to Emission Image Reconstruction from Projections , 1976, IEEE Transactions on Nuclear Science.

[4]  H H Barrett,et al.  Statistical limitations in transaxial tomography. , 1976, Computers in biology and medicine.

[5]  S K Hilal,et al.  Clinical and experimental investigation of a smoothed CT reconstruction algorithm. , 1980, Radiology.

[6]  W Swindell,et al.  A 4-MV CT scanner for radiation therapy: the prototype system. , 1982, Medical physics.

[7]  L. Shepp,et al.  Maximum Likelihood Reconstruction for Emission Tomography , 1983, IEEE Transactions on Medical Imaging.

[8]  P. Joseph An Improved Algorithm for Reprojecting Rays through Pixel Images , 1982 .

[9]  William R. Brody,et al.  Iterative convolution backprojection algorithms for image reconstruction from limited data , 1983 .

[10]  W Swindell,et al.  Computed tomography with a linear accelerator with radiotherapy applications. , 1983, Medical physics.

[11]  W Swindell A 4-MV CT scanner for radiation therapy; spectral properties of the therapy beam. , 1983, Medical physics.

[12]  K. Lange,et al.  EM reconstruction algorithms for emission and transmission tomography. , 1984, Journal of computer assisted tomography.

[13]  L. Shepp,et al.  Maximum Likelihood PET with Real Data , 1984, IEEE Transactions on Nuclear Science.

[14]  Michael I. Miller,et al.  The Use of Sieves to Stabilize Images Produced with the EM Algorithm for Emission Tomography , 1985, IEEE Transactions on Nuclear Science.

[15]  Robert M. Lewitt,et al.  Accelerated Iterative Reconstruction for Positron Emission Tomography Based on the EM Algorithm for Maximum Likelihood Estimation , 1986, IEEE Transactions on Medical Imaging.

[16]  Stephen M. Moore,et al.  An Evaluation of the Use of Sieves for Producing Estimates. Of Radioactivity Distributions with the EM Algorithm for PET , 1986, IEEE Transactions on Nuclear Science.

[17]  C R Crawford,et al.  Reprojection using a parallel backprojector. , 1986, Medical physics.

[18]  L. J. Thomas,et al.  Noise and Edge Artifacts in Maximum-Likelihood Reconstructions for Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[19]  Stuart Geman,et al.  Statistical methods for tomographic image reconstruction , 1987 .

[20]  E. Veklerov,et al.  Stopping Rule for the MLE Algorithm Based on Statistical Hypothesis Testing , 1987, IEEE Transactions on Medical Imaging.

[21]  Linda Kaufman,et al.  Implementing and Accelerating the EM Algorithm for Positron Emission Tomography , 1987, IEEE Transactions on Medical Imaging.

[22]  A Brahme,et al.  Radiotherapeutic computed tomography with scanned photon beams. , 1987, International journal of radiation oncology, biology, physics.

[23]  K. Lange,et al.  A Theoretical Study of Some Maximum Likelihood Algorithms for Emission and Transmission Tomography , 1987, IEEE Transactions on Medical Imaging.

[24]  D. Snyder,et al.  The use of constraints to eliminate artifacts in maximum-likelihood image estimation for emission tomography , 1988 .

[25]  S. B. Lo,et al.  Strip and line path integrals with a square pixel matrix: a unified theory for computational CT projections. , 1988, IEEE transactions on medical imaging.

[26]  A. Dhawan,et al.  A multigrid expectation maximization reconstruction algorithm for positron emission tomography. , 1988, IEEE transactions on medical imaging.

[27]  K F King,et al.  Computed tomography scanning with simultaneous patient translation. , 1990, Medical physics.

[28]  Kenneth M. Hanson,et al.  Method of evaluating image-recovery algorithms based on task performance , 1990 .

[29]  S. Strother,et al.  Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions. , 1991, IEEE transactions on medical imaging.

[30]  Jorge Núñez de Murga,et al.  Preliminary Examination of the Use of Case Specific Medical Information as "prior" in Bayesian Reconstruction , 1991, IPMI.

[31]  Anand Rangarajan,et al.  Bayesian Reconstruction of Functional Images Using Registered Anatomical Images as Priors , 1991, IPMI.

[32]  Richard M. Leahy,et al.  Incorporation of Anatomical MR Data for Improved Dunctional Imaging with PET , 1991, IPMI.

[33]  D. G. Lewis,et al.  A linear array, scintillation crystal-photodiode detector for megavoltage imaging. , 1991, Medical physics.

[34]  M I Miller,et al.  Maximum likelihood SPECT in clinical computation times using mesh-connected parallel computers. , 1991, IEEE transactions on medical imaging.

[35]  F. H. Attix Introduction to Radiological Physics and Radiation Dosimetry , 1991 .

[36]  D. G. Lewis,et al.  A megavoltage CT scanner for radiotherapy verification. , 1992, Physics in medicine and biology.

[37]  Jolyon A. Browne,et al.  Developments with maximum likelihood X-ray computed tomography , 1992, IEEE Trans. Medical Imaging.

[38]  G. Krishna,et al.  Vector-extrapolated fast maximum likelihood estimation algorithms for emission tomography , 1992, IEEE Trans. Medical Imaging.

[39]  T R Miller,et al.  Clinically important characteristics of maximum-likelihood reconstruction. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[40]  J O Deasy,et al.  Tomotherapy: a new concept for the delivery of dynamic conformal radiotherapy. , 1993, Medical physics.

[41]  T R Miller,et al.  Rapidly converging iterative reconstruction algorithms in single-photon emission computed tomography. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[42]  S. Strother,et al.  Iterative algebraic reconstruction algorithms for emission computed tomography: a unified framework and its application to positron emission tomography. , 1993, Medical physics.

[43]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[44]  K Nakagawa,et al.  Real-time beam monitoring in dynamic conformation therapy. , 1994, International journal of radiation oncology, biology, physics.

[45]  Richard E. Carson,et al.  Precision and accuracy of regional radioactivity quantitation using the maximum likelihood EM reconstruction algorithm , 1994, IEEE Trans. Medical Imaging.

[46]  John M. Ollinger,et al.  Maximum-likelihood reconstruction of transmission images in emission computed tomography via the EM algorithm , 1994, IEEE Trans. Medical Imaging.

[47]  K L Lam,et al.  Automated localization of the prostate at the time of treatment using implanted radiopaque markers: technical feasibility. , 1995, International journal of radiation oncology, biology, physics.

[48]  David S. Lalush,et al.  Convergence and resolution recovery of block-iterative EM algorithms modeling 3D detector response in SPECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[49]  E U Mumcuoğlu,et al.  Bayesian reconstruction of PET images: methodology and performance analysis. , 1996, Physics in medicine and biology.

[50]  Max A. Viergever,et al.  Evaluation of OS-EM vs. ML-EM for 1D, 2D and fully 3D SPECT reconstruction , 1996 .

[51]  Alvaro R. De Pierro,et al.  A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography , 1996, IEEE Trans. Medical Imaging.

[52]  N Papanikolaou,et al.  Calculation of portal dose using the convolution/superposition method. , 1996, Medical physics.

[53]  Ronald J. Jaszczak,et al.  Bayesian reconstruction and use of anatomical a priori information for emission tomography , 1996, IEEE Trans. Medical Imaging.

[54]  Stephen J. Glick,et al.  Region of interest evaluation of SPECT image reconstruction methods using a realistic brain phantom , 1996 .

[55]  B R Paliwal,et al.  Modeling dose distributions from portal dose images using the convolution/superposition method. , 1996, Medical physics.

[56]  Jeffrey A. Fessler,et al.  Grouped-coordinate ascent algorithms for penalized-likelihood transmission image reconstruction , 1997, IEEE Transactions on Medical Imaging.

[57]  T. Miller,et al.  Comparison of the convergence properties of the It-W and OS-EM algorithms in SPECT , 1997 .

[58]  Selection of projection set and the order of calculation in ordered subsets expectation maximization method , 1997, 1997 IEEE Nuclear Science Symposium Conference Record.

[59]  Walter Oberschelp,et al.  Expectation maximization reconstruction of positron emission tomography images using anatomical magnetic resonance information , 1997, IEEE Transactions on Medical Imaging.

[60]  A combined 3D megavoltage CT scanner and portal imager for treatment verification in radiotherapy. , 1997 .

[61]  S Webb,et al.  A cone-beam megavoltage CT scanner for treatment verification in conformal radiotherapy. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[62]  M van Herk,et al.  First clinical tests using a liquid-filled electronic portal imaging device and a convolution model for the verification of the midplane dose. , 1998, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[63]  T R Mackie,et al.  Maximum likelihood as a common computational framework in tomotherapy , 1998, Physics in medicine and biology.

[64]  J Dudson,et al.  A feasibility study for megavoltage cone beam CT using a commercial EPID. , 1998, Physics in medicine and biology.

[65]  T. Mackie,et al.  Registration of synthetic tomographic projection data sets using cross-correlation , 1998, Physics in medicine and biology.

[66]  M. Defrise,et al.  Iterative reconstruction for helical CT: a simulation study. , 1998, Physics in medicine and biology.

[67]  M Partridge,et al.  Linear accelerator output variations and their consequences for megavoltage imaging. , 1998, Medical physics.

[68]  B A Groh,et al.  Tomotherapeutic portal imaging for radiation treatment verification. , 1998, Physics in medicine and biology.

[69]  T R Mackie,et al.  Delivery verification in sequential and helical tomotherapy. , 1999, Physics in medicine and biology.

[70]  K. Ruchala,et al.  Image/patient registration from (partial) projection data by the Fourier phase matching method. , 1999, Physics in medicine and biology.

[71]  M E Bellemann,et al.  Subsets and overrelaxation in iterative image reconstruction , 1999, Physics in medicine and biology.

[72]  C. Langer,et al.  Concurrent chemoradiation using paclitaxel and carboplatin in locally advanced non-small cell lung cancer. , 1999, Seminars in radiation oncology.

[73]  T R Mackie,et al.  Registration using tomographic projection files. , 1999, Physics in medicine and biology.

[74]  D A Jaffray,et al.  Managing geometric uncertainty in conformal intensity-modulated radiation therapy. , 1999, Seminars in radiation oncology.

[75]  Gustavo H. Olivera,et al.  SIX PARAMETER PATIENT REGISTRATION DIRECTLY FROM PROJECTION DATA , 1999 .

[76]  Timothy D. Solberg,et al.  Radiation dose in Spiral CT: The relative effects of collimation and pitch , 1999 .

[77]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.